home page

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ISP

10-50VA

ITA

50-3000VA

EUR

multitap 50-3000VA

ET

multitap 50-3000VA

TOR

toroidal 20VA-10kVA

MC

4-20kVA

isolation and safety

TE

50-3000VA

ALI

 50-1000VA LIGHTING 12V

TMIB

 for medical dev. 0.3:2kVA

TMI

 3000-25000VA

TMI64

 medical use 3000-25000VA

ALX

 ip55 class II 200-500VA

three phase transformers

power

TTP

 1-500kVA

isolation and safety

TTI

1-40kVA

TTI-K

k-factor transf. 15-300kVA

autotransfomers

SB

 110/220 revers. 0.1-10kVA

ATM

 single phase 0,1-5kVA

KVA

 three phase 1-500kVA

ATTP

 three phase 1-300kVA

ATTP1

three phase +box 1-300kVA

ATV

motor starting  7-220kW

metal enclosures

metal enclosures

voltage stabilisers

AVR

voltage regulators

SEN

 electronic 1 phase 0.5-2KVA

IMP1

 electronic 1 phase 3-30KVA

R

1ph. servo rack 2-10kVA

RB

1ph. servo motor 2-10kVA

R25

1ph. servo 3-22kVA

RAF

line conditioners HI-FI 1.5-3k

IMP3

 electronic 3 phase
10-2000KVA

RTC

3phase electrom. 6-30kVA

RTC220

3phase electrom. 220V

RTI

three ph.line conditioners

RTG

3phase electrom. to 500kVA

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

frequency converters

GMM

1, 3>1ph. 50/60Hz frequency converter from 3 to 15kVA

GTT

3ph. 50/60Hz frequency converter from 9 to 100kVA

GSC

1ph. 50/60Hz frequency converter 6-9A

GSC

1, 3>1ph. 50/60Hz frequency converter from 20 to 65A

other products

VAR-N

single phase variable autotransformers

VAR-3N

three phase variable autotransformers

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2013 by:

web factory

   

frequency converters - voltage adapters GSC

power from 4.6kW to 15kW

The converter, with an input of 230V and frequency 50Hz or 60Hz, is able to supply any STABILIZED voltages from 0 to 270V a.c., sinusoidal, through the knob placed on th efront panel. The knob is lockable in any positions. Otherwise a remote control on DB9 connector can be also used to regulate the voltage sending an analog signal from 0 to 10V. Using a selector the output frequency cna be changed from 50Hz to 60Hz, no matter at the input frequency. Also the output frequency, as well as the on/off command, can be also sent remotely through the DB9 connector.
The converter works at the full output range within a ±15% on the rated input voltage; from 195V up to 265V the output voltage can be regulated up to 270V.
A practical LCD display shows the output voltage and current.
The max current is limited to 20 A - 30 A – 45 A – 65 A according to the different models.
An input and an output automatic circuit breaker protects the unit against overload and short circuit.
It is also inherently protected from short circuit or overcurrent, as well as the internal overtemperature. This makes the GSC range absolutely reliable and durable.

 PART NO. GSC 20 GSC 30 GSC 45 GSC 65
 Product type

PWM with microprocessor control

 Total efficiency
87%
 INPUT
 Input acceptable voltage
single phase 230 Vac ±15%
(195V : 265V)

Three phase 400 Vac ±15%
(340V : 460V)

 Acceptable frequency
50 o 60 Hz ± 10%
 OUTPUT
 
 Wave form
Sine wave
 Output voltage with voltage regulator
0÷270 Vac ± 1% (manual regulation trough front knob)
 Frequency
50 or 60 Hz ± 0,1% (digital inverter through front switch)
 Harmonic distortion
< 3%
 Crest factor (240Vac)
4:1
 Power (PF  1,0) 20A 30A 45A 65A
 Appearent power (PF  0,7) 4.6Kw 7.6Kw 10.3Kw 14.9Kw
 PROTECTIONS
 Current limiter
40A
 Overload

YES

 Frequency 50/60Hz

YES

 RFI filter

YES

 PFC

YES

 COMMUNICATIONS
 Optical isolated signals (ON/OFF)
YES (max. 230V / 1A, with relay)
sent and received data - inverter fault
 ASCII signals
YES (numeric string)
 CONTROLLI
 Display
Input current, output power %, output voltage, output current, input voltage, output frequency
 LED + sound alarm
Overload, Overtemperature, Off system, Output frequency, input current
 USEFUL DATA
 Direttive
89/336 EEC "Electromagnetic compatibility"
73/23 EEC "Low voltage untill to 1000Vac and 1500Vdc"
 Relative humidity
(40°C 60%) - (25°C 90%)
 Working temperature
-10°C ÷ +65°C
 Max altitude without derating
1000 mt/s.l.m.
 Noise level
40 dBA
 Circulating air volume
100 m³/h
 WEIGHT AND DIMENSIONS
 Height (H) mm 215
 Width (W) mm 482 (front panel size) 440 (enclosure size)
 Depth (D ) mm 450+70 (terminal cover) 650+70 (terminal cover)
 Weight Kg ± 35 39 45 45

Available options:

GSC20TMI - isolation transformer for GSC20 215x485x510 (rack 5U) 20A 35kg
GSC33TMI - isolation transformer for GSC33 215x485x510 (rack 5U) 20A 45kg
GSC45TTI - isolation transformer for GSC45 215x485x510 (rack 5U) 20A 50kg
GSC65TTI - isolation transformer for GSC65 -- 65A 80kg
Output frequency 400Hz
Input voltage 115V - 60Hz
Input voltage 400V a.c. three phase 50Hz (only models GSC20-GSC33)

DOWNLOAD THE INSTRUCTION MANUAL IN ENGLISH LANGUAGE

 

HOME PAGE  -  VERSIONE ITALIANA  -  CREDITS  -  COPYRIGHT - E-MAIL

Data shown on this page are for reference only and can be changed withouth further notice