home page

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ISP

10-50VA

ITA

50-3000VA

EUR

multitap 50-3000VA

ET

multitap 50-3000VA

TOR

toroidal 20VA-10kVA

MC

4-20kVA

isolation and safety

TE

50-3000VA

ALI

 50-1000VA LIGHTING 12V

TMIB

 for medical dev. 0.3:2kVA

TMI

 3000-25000VA

TMI64

 medical use 3000-25000VA

ALX

 ip55 class II 200-500VA

three phase transformers

power

TTP

 1-500kVA

isolation and safety

TTI

1-40kVA

TTI-K

k-factor transf. 15-300kVA

autotransfomers

SB

 110/220 revers. 0.1-10kVA

ATM

 single phase 0,1-5kVA

KVA

 three phase 1-500kVA

ATTP

 three phase 1-300kVA

ATTP1

three phase +box 1-300kVA

ATV

motor starting  7-220kW

metal enclosures

metal enclosures

voltage stabilisers

AVR

voltage regulators

SEN

 electronic 1 phase 0.5-2KVA

IMP1

 electronic 1 phase 3-30KVA

R

1ph. servo rack 2-10kVA

RB

1ph. servo motor 2-10kVA

R25

1ph. servo 3-22kVA

RAF

line conditioners HI-FI 1.5-3k

IMP3

 electronic 3 phase
10-2000KVA

RTC

3phase electrom. 6-30kVA

RTC220

3phase electrom. 220V

RTI

three ph.line conditioners

RTG

3phase electrom. to 500kVA

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

frequency converters

GMM

1, 3>1ph. 50/60Hz frequency converter from 3 to 15kVA

GTT

3ph. 50/60Hz frequency converter from 9 to 100kVA

GSC

1ph. 50/60Hz frequency converter 6-9A

GSC

1, 3>1ph. 50/60Hz frequency converter from 20 to 65A

other products

VAR-N

single phase variable autotransformers

VAR-3N

three phase variable autotransformers

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2013 by:

web factory

SINGLE PHASE SAFETY ISOLATION TRANSFORMERS
FOR LIGHTING "ALI" range

POWER INPUT OUTPUT FREQUENCY STANDARDS
from 50 to 1000VA 230V * 12V 50/60 Hz EN 61558-2-6
CEI 96-7
BS 171
 Open tye
 Grade of protection: IP00
 Isolation class E (Ta max 45°C)
 Separate copper windings cl. F-H
 Protection class:
I
 Resin impregnated and tropicalised

 * 240V and 110V input models also available



power part no. dimensions mm. weight enclosures
VA A B C D E F kg. part no.
50 ALI0091700 77 60 72 62 48 4 1.1 MB01
100 ALI0291700 87 65 80 71 53 5 1.7 MB01
150 ALI0491700 87 75 80 71 63 5 2.1 MB01
200 ALI0591700 98 80 90 82 70 5 3.2 MB02
300 ALI0791700 122 80 120 99 64 6 4.5 MB03
400 ALI0991700 122 90 120 99 74 6 4.9 MB03
500 ALI1191700 122 100 120 99 84 6 5.9 MB03
630 ALI1451700 122 110 120 100 94 6 7.1 MB03
800 ALI1711700 154 100 145 105 94 6 8.9 MB04
1000 ALI1791700 154 110 145 105 104 6 10.9 MB04

Power losses short circuit regulation
VA W voltage % %
50 8 16.2 14.1
100 14 11.0 7.6
150 16 5.0 6.4
200 18 4.9 5.6
300 30 4.5 4.4
400 34 4.0 4.4
500 38 4.0 4.4
630 55 4.0 4.0
800 60 3.8 3.0
1000 75 3.9 3.0

DOWNLOAD THE PDF CATALOGUE