UNINTERRUPTIBLE POWER SUPPLIES EB RANGE |
from 400VA
to 2000VA |
|
|
EB0400-0600-0800 |
EB1000-1400-2000 |
MODEL |
|
EB
400 |
EB
600 |
EB
800 |
CAPACITY |
VA/W |
400VA/240W |
600VA/360W |
800VA/480W |
INPUT |
Voltage |
115VAC or 220/230/240VAC |
|
Voltage Range |
85-140VAC / 162-290VAC |
OUTPUT |
Voltage |
115VAC or 220/230/240VAC |
|
Voltage Regulation(Batt. Mode) |
±10% |
|
Frequency |
50Hz
or 60Hz |
|
Frequency Regulation (Batt. Mode) |
+/-1
Hz |
|
Output Waveform |
Modified Sinewave |
BATTERY |
Battery Type & Number |
6V/4AH x 2pcs |
12V/7AH x 1pc |
12V/9AH x 1pc |
|
Back up Time (at a PC load with 15" monitor) |
12
minutes |
33
minutes |
34
minutes |
|
Recharge Time |
8 hours to 90% after complete discharge |
TRANSFER TIME |
Typical |
2-6ms |
INDICATOR |
AC
Mode |
Green
lighting |
Battery Mode |
Green
flashing |
AUDIBLE ALARM |
Battery Mode |
Sounding every 10 seconds |
Low
Battery |
Sounding every second |
Overload |
Sounding every 0.5 second |
Battery Replacement |
Sounding every 2 seconds |
Fault |
Continously sounding |
PROTECTION |
Full
Protection |
Discharge, overcharge, and overload protection |
PHYSICAL |
Dimension, DXWXH (mm) |
330X100X140 |
Net
Weight (kgs) |
5 |
6 |
6,5 |
ENVIRONMENT |
Operating Environment |
0-
40°C, 0-90 % relative humidity (non-condensing) |
Noise
Level |
Less
than 40dB |
INTERFACE |
Smart
RS-232 |
Support windows 95/98/NT/2000/XP, Novell, and Linux |
MODEL |
|
EB 1000 |
EB 1400 |
EB 2000 |
CAPACITY
|
VA/W |
1000VA/600W |
1400VA/840W |
2000VA/1080W |
INPUT |
Voltage |
115VAC / 220,
230, 240VAC |
Voltage Range |
85-140VAC /
162-290VAC |
OUTPUT |
Voltage |
115VAC / 220,
230, 240VAC |
Voltage
Regulation (Battery Mode) |
±10% |
Frequency |
50Hz or 60Hz |
Frequency
Regulation (Battery Mode) |
+/-1 Hz |
Output Waveform |
Modified Sinewave |
BATTERY |
Battery Type and
Number* |
12V/7AH x 2pcs |
12V/9AH x 2pc |
Back
up Time (at 2-PC load with 15" monitor) |
23 minutes |
25 minutes |
26 minutes |
Recharge Time |
8
Hours to 90% after complete discharge |
TRANSFER TIME |
Typical |
4-6ms |
INDICATOR |
AC Mode |
The
1st green LED lighting |
The
2nd to 5th green LEDs gradually lighting indicating load level |
Battery Mode |
The
1st green LED flashing |
The
2nd to 5th green gradually lighting indicating battery capacity |
Fault |
Red LED lighting |
AUDIBLE ALARM |
Battery Mode |
Sounding every 10
seconds |
Low Battery |
Sounding every
second |
Overload |
Sounding every
0.5 second |
Fault |
Continuously
sounding |
PROTECTION |
Full Protection |
Discharge, Overcharge, and Overload Protection |
PHYSICAL |
Dimension, DxWxH
(mm) |
368.3X140.2X180.4 |
Net Weight (kgs) |
13,8 |
14,2 |
16 |
ENVIRONMENT |
Operating
Environment |
0- 40°C, 0-90 %
Relative Humidity (non-condensing) |
Noise Level |
AC
Mode: Less than 40dB |
Backup Mode: Less than 45dB |
INTERFACE |
Smart RS-232 |
Support Windows 95/98/NT/2000/XP, Novell, and Linux |
|