ECL
uninterruptible power supplies |
power from
0.75kVA to 3kVA |
|
~ Microprocessor
Control
~ built-in AVR to regulate voltagein case of fluctuations or brownout
~ Perfect SINE WAVE output
~ High frequency system
~ "green power" function to protect batteries at no load
~ Extended authonomy through optional battery packs
~ Output voltage selectable by the user
~ RS-232 Communication Port, USB , clean contacts
~ free set-up software
~ Audible and led alarms
~ Protected against short circuit, overload, over-heating
~ Betteries replaceable by the user
~ eternal connector to allow remote control, switch on and off
~ optional accessory to transform the case to a 19" rack module
|
ecl 750-1000 |
|
ecl 1500-2000
with battery pack |
|
ecl 3000 with
battery pack |
TYPE |
ECL0750 * |
ECL1000 |
ECL1500 * |
ECL2000 |
ECL3000 |
POWER |
VA/W |
750VA/500W |
1000VA/700W |
1500VA/1050W |
2000VA/1340W
|
3000VA/2100W
|
INPUT |
Voltage |
220/230/240VAC
|
Input
Range |
Acceptable voltage range |
0-300VAC
|
Frequency |
50Hz / 60Hz ± 5% (Auto Sensing)
|
Minimum
transfer voltage |
154/161/168VAC ± 4%
|
Minimum
network return voltage |
176/184/192VAC ± 4%
|
Maximum transfer voltage |
264/276/288VAC ± 4%
|
Maximum
network return voltage |
254/266/2678VAC ± 4%
|
OUTPUT |
Voltage |
220/230/240VAC
|
Voltage accuracy (battery
mode) |
±5% RMS
|
Frequency |
50Hz o 60Hz
|
Frequency accuracy (battery
mode) |
±0.1Hz
|
Wave form |
perfect SINE WAVE
|
OVERLOAD |
AC mode |
110% -0%+8% shutdown after 3',
150% -0% +10% shutdown after 10 cycles |
Battery mode |
110% ±6% shutdown after 30",
120% ±6% shutdown after 5 cycles |
TEMPO TRASF. |
Tipical |
2-4ms tipico, 6ms max
|
BATTERIES |
Battery type |
12V/7Ah |
12V/9Ah |
12V/7Ah
|
12V/9Ah
|
12V/5Ah
|
No. of batteries |
2 |
2 |
4
|
4
|
8
|
Full load Autonomy |
5'
|
Charging time |
3 h. at 90% aafter full discharge
|
LED ALARMS |
AC
mode |
LINE LED ON
|
Battery mode |
BATTERY LED flashing every 4"
|
Battery load level |
4 segments led
bar: 1 led: 0-25% 2 led: 25-50% 3 led: 50-75% 4 led:
75-100% |
UPS fault |
FAULT LED ON |
Overload |
OVERLOAD LED
ON |
Low Battery |
BATTERY LED
flashing every 1" |
AUDIBLE
ALARMS |
Battery
mode |
BEEP every 4"
|
Battery end |
BEEP every 1" |
UPS fault |
continuous beep |
Overload |
BEEP every 1"
|
Battery replace |
BEEP every 1"
|
DIM. and
Weight |
UPS case |
Dimensions
(PxLxH) mm |
235x87x383 |
235x87x383 |
217x87x414 |
438x87x582
|
438x87x582 |
Weight (kg) |
8.6 |
9.6 |
6.5 |
31.5 |
31.5 |
battery case |
Dimensions
(PxLxH) mm |
ND |
ND |
217X87X414 |
438X87X582 |
438X87X582 |
Weight (kg) |
ND |
ND |
12
|
40 |
40
|
AMBIENTE |
Environment |
0- 40°C, relative humidity 0-90 %
without condensation
|
Noise level |
< 45dB
|
INTERFACCIA |
RS-232 |
Supports Windows, Linux, MAC
|
Contacts |
YES |
YES |
YES |
YES |
YES |
USB |
YES |
YES |
YES |
YES |
YES |
SNMP |
ND |
ND |
OPTIONAL |
OPTIONAL |
OPTIONAL |
EPO
(Emergency power off) |
ND |
YES |
YES |
YES |
YES |
|