Description
The EG1 series is available in ratings from 0.8 KVA to 6 KVA single phase with dual-controlled On-Line technology. This 50/60Hz frequency converter, for its versatility, is suitable to supply any electrical and electronic system even in situations or in combination with the use of motor-powered power generators
Features
A true double conversion frequency converter that provides a perfect current, for a proper high-quality supply of all devices that require power with different frequencies or network voltages.
POWER FACTOR 1
Comparing this line of ON-LINE frequency converters with competition in the current market, we can say that EG1 systems have the best Power Factor output equal to 1. They Provide high performance and efficiency for critical applications.
LARGE INPUT RANGE (110 V -300 V)
EG1 is able to provide stable and clean current to the equipment connect even in very critical and unstable environments
50/60 HZ FREQUENCY CONVERTER FUNCTION
Blocks the output frequency at 50Hz or 60Hz regardless of the incoming frequency and deletes the By-Pass available in the UPS version of the system
(EPO) Emergency Power Off function
This function is used for the emergency switch off in case of fire and other emergency situations.
CONTEMPORARY OPERATION of SNMP-USB-RS232
This feature allows you to use communication from all USB ports, RS-232 and SNMP simultaneously (optional SNMP card).
Model | EG101K-FC | EG101.5K-FC | EG102K-FC | EG103K-FC | |
Power | 800VA – 800W | 1200 VA / 1200 W | 1600 VA / 1600 W | 2400 VA / 2400 W | |
Input | |||||
Rated voltage | 200-208-220-230-240V (or 110V/115V/120V or others on demand) | ||||
Voltage Range | Turn off low/high line | 110VAC / 300VAC ± 3 % @ 50% load
160VAC / 300VAC ± 3 % @ 100% load |
|||
Frequency Range | 40 Hz : 70 Hz | ||||
Phases | single-phase with Neutral + earth | ||||
Power factor P. F. | ≧ 0.99 @ rated voltage (100% load) | ||||
Output | |||||
Rated voltage | 200/208/220/230/240Vac (or 110V/115V/120V or others on demand) | ||||
Voltage Tolerance | ± 1% | ||||
Frequency | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz (to be defined at the time of order) | ||||
Crest Factor | 3:1 | ||||
Harmonic distortion | < 2 % THD (Linear Load)
< 4% THD (nonlinear load) |
||||
Waveform |
PURE SINEWAVE |
||||
Efficiency | |||||
With network present | > 89% | > 91% | |||
Signals | |||||
LCD Panel |
Converter state, Load level, input/output voltage, failure condition |
||||
Alarms | |||||
Overload | Double sound every second | ||||
Fault | Continuous sound | ||||
DIMENSIONS AND WEIGHT | |||||
Tower format | Size, D x W x H (mm) | 397 X 145 X 220 | 421 X 190 X 318 | ||
Net weight (kg) | 7.0 *** | 12.3 *** | |||
ENVIRONMENTAL DATA | |||||
Operational humidity | 20-90%RH @ 0:40°C (No condensation) | ||||
Noise | < 50dBA @ 1 Meter | ||||
Interfaces | |||||
Smart RS-232/USB | Windows family, Linux, Mac | ||||
Optional SNMP | Power management per SNMP manager e web browser |
* An additional code based on the input/output voltages completes the product code
* Input voltages – output other than 230V may result in a derating of the product
** The factory-set output frequency is not reprogrammable by the user
*** weights are referred to the 230V input/exit model – weights may vary depending on input/output voltages
MODEL | EG106K-FC | EG110K-FC | |||
Phases | Input Single Phase / Output Single-Phase | ||||
Rated Power | 3600VA / 3600W | 6000VA / 6000W | |||
10’ rated power | 3960VA / 3960W | 6600VA / 6600W | |||
1’ rated power | 4680VA / 4680W | 7800VA / 7800W | |||
Input | |||||
Rated voltage |
230V (or 110V/115V/120V or other on demand) |
||||
Voltage Range | Turn off low line | 176 VAC @ 100% of the load
110 VAC @ 50% of the load |
|||
Return from deactivation | 186 VAC @ 100% of the load
120 VAC @ 50% of the load |
||||
Turn off high line | 300 VAC | ||||
Return from deactivation | 290 VAC | ||||
Frequency Range | 46-54 Hz @ 50Hz / 56-64 Hz @ 60Hz | ||||
Power factor P.F. | > 0.99 @ 100% load | ||||
Output | |||||
Rated voltage | 200/208/220/230/240V (or 110V/115V/120V or other on demand) | ||||
Voltage Tolerance | ± 1% | ||||
Frequency | 50 Hz ±0.1Hz or 60 Hz ±1Hz (to be defined at the time of order) | ||||
Crest Factor | 3:1 | ||||
Harmonic distortion | 2% THD (linear load)
4% THD (nonlinear load) |
||||
Waveform | PURE SINEWAVE | ||||
Efficiency | |||||
With network present |
94% |
||||
Signals | |||||
LCD Panel |
Converter Status, Load Level, Input/Output voltage, Fault Condition |
||||
Alarms | |||||
Overload (overhead) | Double sound every second | ||||
Fault | Continuous sound | ||||
DIMENSIONS AND WEIGHT | |||||
Tower format | Size, D x W x H (mm) | 592 X 250 X 576 | |||
Net weight (kg) | 30 *** | 30 *** | |||
ENVIRONMENTAL DATA | |||||
Operational humidity | 20-90 % RH @ 0- 40°C(no condensation) | ||||
Noise | < 55dBA @ 1 m | < 58dB @ 1 m | |||
Interfaces | |||||
Smart RS-232 | Windows family, Linux, Mac | ||||
USB | |||||
Optional SNMP | Power management per SNMP manager e web browser |
* An additional code based on the input/output voltages completes the product code
* Input voltages – output other than 230V may result in a derating of the product
** The factory-set output frequency is not reprogrammable by the user
*** weights are referred to the 230V input/exit model – weights may vary depending on input/output voltages