PLA – UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, form 10 to 200KVA

  1. Request for Information





    Your Name (required)
    Your email (required)
    Phone (advised)
    Your request
    I hereby declare I read the privacy information e authorize personal data treatment according to the italian law 196/2003. Above data will be exclusively used for the above purpose (commercial information about our products) and will be not shared with any third parties.
  2. Download

Description

PLA is a true on-line UPS, double conversion technology with high efficiency. Input and Output voltages are three-phase. Rating power available from 10kVA to 200kVA. High performance and high efficiency with PF 0,9. PLA uses power modular technology and it works in redundance mode N+x. It is a flexible system, in fact is possible to add or remove power cabinets depending by the amount of load to supply. In this way it is possible to optimize the financial investments by escalating the configuration according to the real needs. PLA can be used for any kind of load: IT, AUTOMATIC MACHINE, DATA CENTER, HOSPITAL, INDUSTRY, etc. PLA can solve every kind of problems, such as blackouts, spikes, voltage disturbances, frequency disturbances, harmonic distortion (THD <2%) current noise, brownouts, surges, and so on. PLA series uses a Digital Signal Processor (DSP) control to increase the reliability, the efficiency, and for auto protection and auto diagnosis. PLA series keep input current balanced. No unbalance problems may occur during the operation.

MAIN FEATURES

  • True On-line UPS input three-phase + N, output three-phase + N
  • Switching time 0 ms
  • Power factor 0,9 – (optional 0,8)
  • LCD display
  • Modular power from 10kVA to 200kVA
  • DSP (Digital Signal Processor)
  • Input Low distortion < 2%
  • ECO mode function

Optional: SNMP, MODBUS, RELAY. Standard: USB port, RS485, EPO contact

MODULAR POWER TECHNOLOGY

Modular power technology used for PLA series is an easy “Parallel concept”.

PLA series has an intelligent sensor which automatically detects other UPSs with same power.

No settings via software, no parallel boards needed, UPS it is always ready and with a self test reset and adjust its

output power.

Parallel control cables are shielded with double isolation to avoid noise interference.

The cables are connected in ring mode, as shown in the picture below.

Ring connection is very reliable.

The parallel configuration guarantees an higher reliability than a single “full power” UPS. For making a correct

configuration it is important to meet the items written below:

1) Every UPS must have the same power and connected to the same by-pass line .

2) The electric cables (input, output, by-pass) must have the same length and same characteristic

MODEL PLA10 PLA15 PLA20 PLA30 PLA40 PLA60
Input Power 10KVA

9KW

15KVA

13.5KW

20KVA

18KW

30KVA

27KW

40KVA

36KW

60KVA

54KW

No. of phases 3 phase 4 wires + PE
Rated voltage 380/400/415Vac
Voltage range 208~478Vac
Frequency range 45-55Hz a 50Hz / 56-66Hz to 60Hz (auto sensing)
Power factor ≥0.99
THDi ≤2%(100% non linear load)
By-pass voltage range Max voltage.:                      220Vac:+25% (optional +5%,+10%,+15% )
230Vac:+20% (optional +10%,+15% )
240Vac:+15% (optional +10% )
Min voltage.:                       -45% (optional -20%、-30%)
Frequency protection range: ±10%
Generator input Supported
Output No. of phases 3 phase 4 wires + PE
Rated voltage 380/400/415Vac
Power factor 0.9
Voltage accuracy ±1%
Frequency Line ±1%、±2%、±4%、±5%、±10% rated frequency (optional)
Battery (50/60±0.1%)Hz
Crest Factor 3:1
THD ≤1% linear load – ≤3% non linear load
Efficiency ≥96,5% ≥97,5%
Battery Quantity Dynamic 16-18-20pcs (configurable)
Autonomy 10’ standard with embedded battery
Overload Normal op.: 110% 60′ – 125% 10′ – 150% 1′ – >150% switch to bypass
Self-check Automatic self test at switch on
Display LCD: Voltage IN/OUT – Frequency IN/OUT – Load – Battery Voltage

Operating Temp. – Overload – Failure – Alarms

Interface USB – RS485 – Clean Contacts- Intelligent slot
Communication SNMP (optional) – MODBUS (optional) – RELAY card (optional)
Operating temperature Operating: 0° + 40° / Storage: -25° + 55°
Dimensions (DxWxH) mm 828x250x868 828x500x868
Number of units 1 2

  

MODEL PLA80 PLA100 PLA120 PLA160 PLA180 PLA200
Input Power 80KVA

72KW

100KVA

90KW

120KVA

108KW

160KVA

144KW

180KVA

144KW

200KVA

160KW

No. of phases 3 phase 4 wires + PE
Rated voltage 380/400/415Vac
Voltage range 208~478Vac
Frequency range 45-55Hz a 50Hz / 56-66Hz to 60Hz (auto sensing)
Power factor ≥0.99
THDi ≤2%(100% non linear load)
By-pass voltage range Max voltage.:                      220Vac:+25% (optional +5%,+10%,+15% )
230Vac:+20% (optional +10%,+15% )
240Vac:+15% (optional +10% )
Min voltage.:                       -45% (optional -20%、-30%)
Frequency protection range: ±10%
Generator input Supported
Output No. of phases 3 phase 4 wires + PE
Rated voltage 380/400/415Vac
Power factor 0.9 0.8
Voltage accuracy ±1%
Frequency Line ±1%、±2%、±4%、±5%、±10% rated frequency (optional)
Battery (50/60±0.1%)Hz
Crest Factor 3:1
THD ≤1% linear load – ≤3% non linear load
Efficiency ≥96,5% ≥97,5%
Battery Quantity Dynamic 16-18-20pcs (configurable)
Autonomy 10’ standard with embedded battery
Overload Normal op.: 110% 60′ – 125% 10′ – 150% 1′ – >150% switch to bypass
Self-check Automatic self test at switch on
Display LCD: Voltage IN/OUT – Frequency IN/OUT – Load – Battery Voltage

Operating Temp. – Overload – Failure – Alarms

Interface USB – RS485 – Clean Contacts- Intelligent slot
Communication SNMP (optional) – MODBUS (optional) – RELAY card (optional)
Operating temperature Operating: 0° + 40° / Storage: -25° + 55°
Dimensions (DxWxH) mm 828x500x868 828x750x868 828x1000x868
Number of units 2 3 4

 

Additional Information

potenza kVA

4, 5, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 80

tensioni secondario

12-24, 24-48, 55-110, 110-220