{"id":12500,"date":"2024-02-25T12:57:30","date_gmt":"2024-02-25T11:57:30","guid":{"rendered":"https:\/\/www.kfactor.it\/?post_type=product&#038;p=12500"},"modified":"2026-03-15T17:41:39","modified_gmt":"2026-03-15T16:41:39","slug":"mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/","title":{"rendered":"MT &#8211; UPS EMERGENCY POWER SUPPLY CEI 0-16 ONLINE DOUBLE CONVERSION SINE WAVE 1-3KVA"},"content":{"rendered":"<p>The range of MV Emergency power supplies guarantees complete protection for the power supply of the auxiliary cabins, guaranteeing a power reserve for the resetting of the minimum voltage coil.<\/p>\n<p>Additional battery boxes are available that allow the autonomy to be extended up to 3 hours with nominal load.<\/p>\n<p>Relay cards are optionally available to remotely report the status of the machine, or alternatively an SNMP network card.<\/p>\n<p>The minimum voltage coil and the control circuits of the Medium Voltage circuit breakers must be powered by the same auxiliary voltage coming from the Rescuer (UPS) with an autonomy of 60 minutes.<\/p>\n<p>In the event of a long interruption due to maintenance or breakdown, the Medium Voltage Circuit Breaker must be re-energized by suitably trained personnel.<\/p>\n<p>Before closing the main disconnector, it is necessary to power the Medium Voltage switch.<\/p>\n<p><strong>FEATURES<\/strong><\/p>\n<ul>\n<li>On-line double conversion with Digital Signal Processor (DSP) digital control technology.<\/li>\n<li>High PF at input and output<\/li>\n<li>Wide range of input tolerance (energy saving)<\/li>\n<li>Eco Mode (Economic operation mode)<\/li>\n<li>Energy return protection and dedicated filtering (Surge Protection)<\/li>\n<li>Monitoring and self-diagnosis at each start-up<\/li>\n<li>Cold Start<\/li>\n<li>Exit by-pass<\/li>\n<li>Possibility of autonomy expansion with additional battery boxes<\/li>\n<li>USB port<\/li>\n<li>Even software<\/li>\n<li>Intelligent SNMP network card slot (optional)<\/li>\n<\/ul>\n<p>The MT series is produced with an LCD display from which the operating parameters (more than 50 items) can be viewed, and from where it is possible to set the basic configurations.<\/p>\n<table width=\"718\">\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"247\"><strong>MODEL<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"159\"><strong>MT01<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"161\"><strong>MT02<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"151\"><strong>MT03<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"247\"><strong>POWER RATING<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"159\"><strong>1000VA \/ 900W<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"161\"><strong>2000VA \/ 1800W<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"151\"><strong>3000VA \/ 2700W<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\" width=\"30\"><strong>INPUT<\/strong><\/td>\n<td colspan=\"2\" width=\"217\">Input Type<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">Single-phase grounded<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Voltage Range<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">115\u00b15VAC-295\u00b15VAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Frequency Range<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">45Hz-55Hz@50Hz \/ 55Hz-65Hz@60Hz autosensing<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Power factor<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">\u22650.99<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Technology<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">ON LINE DOUBLE CONVERSION VFI-SS-111<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Intervallo bypass<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">186VAC-252VAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">THDi<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">\u22643% (100% nonlinear load)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Connections<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"320\">1x IEC<\/td>\n<td style=\"text-align: center;\" width=\"151\">1x L\/W + T terminal block<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"16\" width=\"30\"><strong>OUTPUT<\/strong><\/td>\n<td colspan=\"2\" width=\"217\">Output Type<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">Single-phase grounded<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Rated voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">208\/220\/230\/240VAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Power factor<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">0.9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Voltage accuracy<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">\u00b12%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"120\">Frequency<\/td>\n<td width=\"96\">Normal Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">1. When the input frequency is in range, the output frequency is the same as the input frequency.<\/p>\n<p>When the frequency is out of range, the output frequency is (50\/60\u00b10.2) Hz as when switching to battery mode<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Battery Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">(50\/60\u00b10.2) Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Crest factor<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">3:1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Switching time<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">Network \u2190\u2192 battery = 0ms<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"120\">Overload<\/td>\n<td width=\"96\">Battery Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">108%\u00b15%&lt;load\u2264150%\u00b15%\u00a0\u00a0 &gt;30s shuts off the output and warns,<\/p>\n<p>150%\u00b15%&lt;Load&lt;200%\u00b15% &gt; 300ms interrupts output and warns<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Normal Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">108%\u00b15%&lt;load\u2264150%\u00b15% &gt; 30s switches to bypass and warns<\/p>\n<p>150%\u00b15%&lt;load&lt;200%\u00b15% &gt;300ms switches to bypass and warns<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"120\">Efficiency<\/td>\n<td width=\"96\">Normal Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">100% load \u226592%<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">Battery Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">100% load \u226590%<\/td>\n<\/tr>\n<tr>\n<td width=\"96\">ECHO<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">100% load \u226597%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" width=\"217\">Output voltage distortion<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">\u22643% (100% linear load)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">\u22645% (100% non-linear load)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Connections<\/td>\n<td style=\"text-align: center;\" width=\"159\">2x IEC<\/p>\n<p>1x Schuko<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"312\">6x IEC<\/p>\n<p>1x Schuko<\/p>\n<p>1x L\/W + T terminal block<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"30\"><strong>BATTERY<\/strong><\/td>\n<td colspan=\"2\" width=\"217\">Input Battery Voltage<\/td>\n<td style=\"text-align: center;\" width=\"159\">24VDC<\/td>\n<td style=\"text-align: center;\" width=\"161\">48VDC<\/td>\n<td style=\"text-align: center;\" width=\"151\">72VDC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Internal batteries quantity<\/td>\n<td style=\"text-align: center;\" width=\"159\">2<\/td>\n<td style=\"text-align: center;\" width=\"161\">4<\/td>\n<td style=\"text-align: center;\" width=\"151\">6<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Internal battery type<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">Battery 12V\/7-9AH Maintenance-Free Airtight Lead Acid Battery<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Runtime<\/td>\n<td style=\"text-align: center;\" width=\"159\">60 MIN. 50W<\/td>\n<td style=\"text-align: center;\" width=\"161\">60 MIN. 100W<\/td>\n<td style=\"text-align: center;\" width=\"151\">60 MIN. 150W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Charging current (A)<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">1,2<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"30\"><strong>ENVIRONMENT<\/strong><\/td>\n<td colspan=\"2\" width=\"217\">Standard<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">IEC\/EN 62040-1 &#8211; IEC\/EN 62040-2 &#8211; IEC\/EN 62040-3 &#8211; IEC\/EN 60950-1 &#8211; IEC 0-16<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">0\u00b0C~40\u00b0C (excluding batteries)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Relative humidity<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">0~95% non-condensing<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Max Working Altitude<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">&lt;1500m &#8211; if &gt;1500m, reduce the rated power for use<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Storage Temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">-25\u00b0C~55\u00b0C (excluding batteries)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"217\">Noise<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">&lt; 50dB @ 1mt<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"247\">DIMENSIONS (WxDxH) mm<\/td>\n<td style=\"text-align: center;\" width=\"159\">144x400x215<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"312\">191x470x336<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"247\">WEIGHT KG. (gross\/net)<\/td>\n<td style=\"text-align: center;\" width=\"159\">10,3\/9.3<\/td>\n<td style=\"text-align: center;\" width=\"161\">20.8\/18.8<\/td>\n<td style=\"text-align: center;\" width=\"151\">25.8\/23.8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"247\">Included parts<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"471\">Instruction manual, software, USB cable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Download the datasheet for the <a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/07\/k-factor-ups-bbt-bbr-battery_box_r1.0_20250729_ita.pdf\" target=\"_blank\" rel=\"noopener\">Battery box<\/a> here.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The range of MV Emergency power supplies guarantees complete protection for the power supply of the auxiliary cabins, guaranteeing a power reserve for the resetting of the minimum voltage coil. Additional battery boxes are available that allow the autonomy to be extended up to 3 hours with nominal load. Relay cards are optionally available to [&hellip;]<\/p>\n","protected":false},"featured_media":13853,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[685,692,221],"product_tag":[329,579,280,273,328],"class_list":["post-12500","product","type-product","status-publish","has-post-thumbnail","product_cat-emergency-power-supplies","product_cat-single-phase-uninterruptible-power-supplies","product_cat-uninterruptible-power-supplies","product_tag-double-conversion-ups-2","product_tag-on-line-power-supply","product_tag-uninterruptible-power-supplies","product_tag-uninterruptible-power-supply-2","product_tag-ups","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","outofstock","taxable","shipping-taxable","product-type-variable"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>MT - UPS EMERGENCY POWER SUPPLY CEI 0-16 ONLINE DOUBLE CONVERSION SINE WAVE 1-3KVA - K-factor<\/title>\n<meta name=\"description\" content=\"Online double conversion UPS with pure sine wave output and DSP (Digital Signal Processor) digital control technology.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MT - UPS EMERGENCY POWER SUPPLY CEI 0-16 ONLINE DOUBLE CONVERSION SINE WAVE 1-3KVA - K-factor\" \/>\n<meta property=\"og:description\" content=\"Online double conversion UPS with pure sine wave output and DSP (Digital Signal Processor) digital control technology.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-15T16:41:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-msn01-02-03_01.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\\\/\",\"name\":\"MT - UPS EMERGENCY POWER SUPPLY CEI 0-16 ONLINE DOUBLE CONVERSION SINE WAVE 1-3KVA - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-msn01-02-03_01.jpg\",\"datePublished\":\"2024-02-25T11:57:30+00:00\",\"dateModified\":\"2026-03-15T16:41:39+00:00\",\"description\":\"Online double conversion UPS with pure sine wave output and DSP (Digital Signal Processor) digital control technology.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-msn01-02-03_01.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-msn01-02-03_01.jpg\",\"width\":1280,\"height\":720,\"caption\":\"Gruppi statici di continuit\u00e0 1-2-3kva onda sinusoidale doppia conversione\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"MT &#8211; UPS EMERGENCY POWER SUPPLY CEI 0-16 ONLINE DOUBLE CONVERSION SINE WAVE 1-3KVA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"ELECTRONICS MADE EASY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"MT - UPS EMERGENCY POWER SUPPLY CEI 0-16 ONLINE DOUBLE CONVERSION SINE WAVE 1-3KVA - K-factor","description":"Online double conversion UPS with pure sine wave output and DSP (Digital Signal Processor) digital control technology.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/","og_locale":"en_US","og_type":"article","og_title":"MT - UPS EMERGENCY POWER SUPPLY CEI 0-16 ONLINE DOUBLE CONVERSION SINE WAVE 1-3KVA - K-factor","og_description":"Online double conversion UPS with pure sine wave output and DSP (Digital Signal Processor) digital control technology.","og_url":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/","og_site_name":"K-factor","article_modified_time":"2026-03-15T16:41:39+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-msn01-02-03_01.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/","url":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/","name":"MT - UPS EMERGENCY POWER SUPPLY CEI 0-16 ONLINE DOUBLE CONVERSION SINE WAVE 1-3KVA - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-msn01-02-03_01.jpg","datePublished":"2024-02-25T11:57:30+00:00","dateModified":"2026-03-15T16:41:39+00:00","description":"Online double conversion UPS with pure sine wave output and DSP (Digital Signal Processor) digital control technology.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-msn01-02-03_01.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-msn01-02-03_01.jpg","width":1280,"height":720,"caption":"Gruppi statici di continuit\u00e0 1-2-3kva onda sinusoidale doppia conversione"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/mt-ups-rescuer-cei-0-16-online-double-conversion-sine-wave-1-3kva\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"PRODUCTS","item":"https:\/\/www.kfactor.it\/en\/shop\/"},{"@type":"ListItem","position":2,"name":"MT &#8211; UPS EMERGENCY POWER SUPPLY CEI 0-16 ONLINE DOUBLE CONVERSION SINE WAVE 1-3KVA"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"ELECTRONICS MADE EASY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product\/12500","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media\/13853"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media?parent=12500"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_brand?post=12500"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_cat?post=12500"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_tag?post=12500"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}