{"id":12530,"date":"2024-02-15T15:38:42","date_gmt":"2024-02-15T14:38:42","guid":{"rendered":"https:\/\/www.kfactor.it\/?post_type=product&#038;p=12530"},"modified":"2026-04-24T08:33:54","modified_gmt":"2026-04-24T06:33:54","slug":"flx-19-tower-rack-ups-online-double-conversion-sine-wave-1kva-to-10kva","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/flx-19-tower-rack-ups-online-double-conversion-sine-wave-1kva-to-10kva\/","title":{"rendered":"FLX &#8211; 19&#8243;\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA"},"content":{"rendered":"<div>\n<h3 class=\"tbp_title\">FLX \u2013 19\u2033\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA<\/h3>\n<p>On-line double conversion with Digital Signal Processor (DSP) digital control technology.<\/p>\n<\/div>\n<div>Among the main features that make this series highly efficient we point out:<\/div>\n<ul>\n<li>High PF in input and output<\/li>\n<li>Wide range of input tolerance (energy saving)<\/li>\n<li>Eco Mode (Economic operation mode)<\/li>\n<li>Flexibility and paralleling possibilities<\/li>\n<li>Energy return protection and dedicated filtering (Surge Protection)<\/li>\n<li>Monitoring and self-diagnosis at each start-up<\/li>\n<li>Cold Start<\/li>\n<li>By-pass<\/li>\n<li>Possibility of autonomy expansion with additional battery boxes<\/li>\n<li>USB port<\/li>\n<li>Contact EPO<\/li>\n<li>Software included<\/li>\n<li>Intelligent SNMP network card slot<strong>\u00a0<\/strong><\/li>\n<\/ul>\n<div>\n<table width=\"710\">\n<tbody>\n<tr>\n<td colspan=\"4\" width=\"159\"><strong>MODEL<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"184\"><strong>FLX01<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"184\"><strong>FLX01.5<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"184\"><strong>FLX03<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Type Input\/Output<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">Single-phase grounded<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Rated power<\/td>\n<td style=\"text-align: center;\" width=\"184\">1000VA \/900W<\/td>\n<td style=\"text-align: center;\" width=\"184\">1500VA \/1350W<\/td>\n<td style=\"text-align: center;\" width=\"184\">3000VA \/2700W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"710\"><strong>INPUT<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Voltage rating<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">208\/220\/230\/240Vac<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\" width=\"84\">Range of<\/p>\n<p>tension<\/p>\n<p>(Temp.<\/p>\n<p>Environment<\/p>\n<p>&lt;40\u00b0C)<\/td>\n<td colspan=\"2\" width=\"75\">Low line transfer<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">176Vac\u00b15% @100%-50% load<\/p>\n<p>110Vac\u00b15% @50%-0% load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"75\">Low line comeback<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">186Vac\u00b15% @100%-50% load<\/p>\n<p>120Vac\u00b15% @50%-0% load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"75\">High line transfer<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">264Vac\u00b15% @100%-50% load<\/p>\n<p>300Vac\u00b15% @50%-0% load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"75\">High line comeback<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">254Vac\u00b15% @100%-50% load<\/p>\n<p>290Vac\u00b15% @50%-0% load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Frequency Range **<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">40-70Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Power factor<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">0.99@100% load (Rated input voltage)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Bypass range<\/td>\n<td colspan=\"3\" width=\"551\">\n<p style=\"text-align: center;\"><strong>High voltage point Bypass<\/strong><br \/>\n<strong>230-264<\/strong>: high voltage point setting in the LCD display from 230Vac to 264Vac. (Default: 264Vac)<br \/>\n<strong>Low Voltage Point Bypass<\/strong><br \/>\n<strong>176-220<\/strong>:\u00a0 Low voltage point setting on the LCD display from 176Vac to 220Vac. (Default: 176Vac)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Connection Type<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">IEC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Generator input<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">Supported<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"710\"><strong>OUTPUT<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Output Voltage *<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">208\/220\/230\/240Vac<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Power factor<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">0.9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Voltage regulation<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"84\">Frequency<\/td>\n<td colspan=\"3\" width=\"75\">Normal Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">46-54Hz or 56-64Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"75\">Battery Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">(50\/60\u00b10.1)Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Crest factor<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">3:1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Harmonic Distortion (THDv)<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">\u22643% THD with linear load \u22645% THD with nonlinear load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Waveform<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">Pure sine wave<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" width=\"85\">Switching time<\/td>\n<td width=\"74\">Network<\/p>\n<p>&lt;-&gt; Battery<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">0 ms<\/td>\n<\/tr>\n<tr>\n<td width=\"74\">Inverter &lt;-&gt; Bypass<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">4 ms (Typical)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Efficiency<\/td>\n<td style=\"text-align: center;\" width=\"184\">88% (AC mode)<\/p>\n<p>85% (DC mode)<\/td>\n<td style=\"text-align: center;\" width=\"184\">89% (AC mode)<\/p>\n<p>86% (DC mode)<\/td>\n<td style=\"text-align: center;\" width=\"184\">90% (AC mode)<\/p>\n<p>87% (DC mode)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"159\">Connections<\/td>\n<td style=\"text-align: center;\" width=\"184\">2x IEC<\/p>\n<p>1x Schuko<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"367\">6x IEC<\/p>\n<p>1x Schuko \u2013 1x Terminal Block L\/W + T<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"710\">\n<tbody>\n<tr>\n<td colspan=\"5\" width=\"710\"><strong>BATTERY<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Type<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">12V\/9Ah<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Quantity<\/td>\n<td style=\"text-align: center;\" width=\"184\">2<\/td>\n<td style=\"text-align: center;\" width=\"184\">3<\/td>\n<td style=\"text-align: center;\" width=\"184\">6<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Input Battery Voltage<\/td>\n<td style=\"text-align: center;\" width=\"184\">24Vdc<\/td>\n<td style=\"text-align: center;\" width=\"184\">36Vdc<\/td>\n<td style=\"text-align: center;\" width=\"184\">72Vdc<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Runtime<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">10min (refers to standard UPS only), for long-range UPS, the runtime time is determined by the battery capacity.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Typical charging time (standard model)<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">4 hours at 90% capacity<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Charging voltage<\/td>\n<td style=\"text-align: center;\" width=\"184\">27.4V \u00b11%<\/td>\n<td style=\"text-align: center;\" width=\"184\">41.0 \u00b11%<\/td>\n<td style=\"text-align: center;\" width=\"184\">82.1 \u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Charging current<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">1A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"710\"><strong>SYSTEM FEATURES<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"90\">Overload<\/td>\n<td width=\"69\">Normal Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">105%~125%: UPS transfer to bypass after 1 minute when the network is normal<\/p>\n<p>125%~130%: UPS transfer to bypass after 30 seconds when the network is normal<\/p>\n<p>&gt;130%: UPS transfer to bypass immediately when the network is normal<\/td>\n<\/tr>\n<tr>\n<td width=\"69\">Battery Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">105%~125%: UPS after 1 minute shuts down;<\/p>\n<p>125%~130%: UPS after 10 seconds shuts down;<\/p>\n<p>&gt;130%: UPS shuts down immediately<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Short Circuit<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">Includes the entire system<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Overtemperature<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">Normal Mode: Switch to Bypass; Battery Mode: Immediately shuts down the UPS<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Low battery voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">Alarm and shutdown<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">EPO<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">Immediately turns off the UPS<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Visible and audible alarms<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">Mains failure, Low battery, Overcharge, System failure<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Communication interface<\/td>\n<td colspan=\"3\" width=\"551\">\n<p style=\"text-align: center;\">USB (or RS232), SNMP card (optional), Relay card (optional)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"710\"><strong>ENVIRONMENT<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Operating Temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">0\u00b0C~40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Storage Temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">-25\u00b0C~55\u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Relative humidity<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">20-90 % RH @ 0- 40\u00b0C (non-condensing)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Altitude<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">&lt; 1500m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Noise<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">Less than 55dBA at 1 Meter<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"710\"><strong>MECHANICAL SPECIFICATIONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Dimensions W\u00d7D\u00d7H (mm)<\/td>\n<td style=\"text-align: center;\" width=\"184\">440*325*86.5 (2U)<\/td>\n<td style=\"text-align: center;\" width=\"184\">440*460*86.5 (2U)<\/td>\n<td style=\"text-align: center;\" width=\"184\">440*520*131 (3U)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Net weight (kg)<\/td>\n<td style=\"text-align: center;\" width=\"184\">11.3<\/td>\n<td style=\"text-align: center;\" width=\"184\">16.5<\/td>\n<td style=\"text-align: center;\" width=\"184\">26.2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"710\"><strong>STANDARDS<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">Safety<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">IEC\/EN62040-1,IEC\/EN60950-1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"159\">EMC<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"551\">IEC\/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,<\/p>\n<p>IEC61000-4-5,IEC61000-4-6,IEC61000-4-8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u00a0<\/strong>* Downgrades to 80% rating when the output voltage is regulated to 208V AC<\/p>\n<p>** Downgrade to 75% rating when the input voltage frequency is out of range (50\/60\u00b14Hz)<\/p>\n<p>Product specifications are subject to change without further notice.<strong>\u00a0<\/strong><\/p>\n<table width=\"659\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"235\"><strong>MODEL<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"197\"><strong>FLX06<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"228\"><strong>FLX10<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Stages<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">Single-phase grounded<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Power (VA\/Watts)<\/td>\n<td style=\"text-align: center;\" width=\"197\">6000VA \/ 5400W<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"228\">10000VA \/ 9000W<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"659\"><strong>ENTRANCE<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Rated voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">208\/220\/230\/240VAC<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"84\">Working Voltage Range<\/td>\n<td width=\"150\">Low line transfer<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">187Vac\u00b15% @ 100%-80% load<\/p>\n<p>160Vac\u00b15% @ 80%-70% load<\/p>\n<p>140Vac\u00b15% @ 70%-60% load<\/p>\n<p>120Vac\u00b15% @ 60%-50% load<\/p>\n<p>110Vac\u00b15% @ 50%-0% load<\/p>\n<p>(Ambient temperature. &lt;35\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td width=\"150\">High line transfer<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">300Vac \u00b15%<\/td>\n<\/tr>\n<tr>\n<td width=\"150\">High line comeback<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">290Vac \u00b15%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Frequency range<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">50-60Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power Factor<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">\u22650.99@100% load (rated input voltage)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"659\"><strong>EXIT<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Output voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">208\/220\/230\/240Vac<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power Factor<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">0,9<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Voltage regulation<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"84\">Frequency<\/td>\n<td width=\"150\">On Network<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">50-60Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"150\">Battery<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">(50\/60\u00b10.1)Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Crest factor<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">3:1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Harmonic Distortion (THDv)<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">\u22642% THD with linear load<\/p>\n<p>\u22645% THD with nonlinear load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Waveform<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">Sinusoidale<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"84\">Transfer time<\/td>\n<td width=\"150\">From mains to battery<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">Zero<\/td>\n<\/tr>\n<tr>\n<td width=\"150\">Da inverter a bypass<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">4ms (typical)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Efficiency<\/td>\n<td style=\"text-align: center;\" width=\"197\">&gt;94% (AC mode)<\/p>\n<p>&gt;89% (DC mode)<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"228\">&gt;94.5% (AC mode)<\/p>\n<p>&gt;89% (DC mode)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"659\"><strong>BATTERY<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Battery type<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"212\">7Ah (in external battery cabinet)<\/td>\n<td style=\"text-align: center;\" width=\"212\">9Ah (in external battery cabinet)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Number of batteries<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">16 (standard)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Autonomy<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">It depends on the capacity of the batteries<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Charging time<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">4 hours at 90% capacity (typical)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Charging voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">219.2 VDC \u00b11%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Charging current<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">12A max, can be set by LCD<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"659\"><strong>FEATURES<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Line Mode \/ Battery Mode<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\"><strong>Ambient temperature &lt;35\u00b0C<\/strong><\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 105%~110%: UPS shuts down after 60 minutes in battery mode or switches to Bypass with mains present.<\/p>\n<p style=\"text-align: center;\">\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 110%~130%: UPS shuts down after 5 minutes in battery mode or switches to Bypass with mains present.<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 &gt;130%: UPS shuts down after 3 sec in battery mode or switches to Bypass with mains present.<\/p>\n<p><strong>35\u00b0C&lt; Ambient temperature &lt;40\u00b0C<\/strong><\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 105%~110%: UPS shuts down after 1 minute in battery mode or switches to Bypass with mains present.<\/p>\n<p>\u00b7\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 &gt;110%: UPS shuts down after 3 sec in battery mode or switches to Bypass with network present.<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Short Circuit<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">Entire system<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Overtemperature<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">Normal Mode: Toggle to Bypass; Battery Mode: Immediately turns off the UPS<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Low battery voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">Alarm and Ups Turns Off<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">EPO (optional)<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">Immediately turns off the UPS<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Visual and audible alarms<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">Mains failure, Low battery, Overcharge, Fault<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"235\">Communication interfaces<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"425\">USB \/ RS232, SNMP card (optional), Relay card (optional)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"659\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"659\"><strong>ENVIRONMENT<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Working Temperature<\/td>\n<td style=\"text-align: center;\" width=\"425\">0\u00b0C~40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Storage Temperature<\/td>\n<td style=\"text-align: center;\" width=\"425\">-25\u00b0C~55\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Relative humidity<\/td>\n<td style=\"text-align: center;\" width=\"425\">20-90 % RH @ 0- 40\u00b0C (non-condensing)<\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Altitude<\/td>\n<td style=\"text-align: center;\" width=\"425\">&lt; 1500m<\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Noise<\/td>\n<td style=\"text-align: center;\" width=\"425\">Less than 50dBA at 1 Meter<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"659\"><strong>MECHANICAL SPECIFICATIONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Dimensions W\u00d7H\u00d7D (mm)<\/td>\n<td style=\"text-align: center;\" width=\"425\">440*132*450 (3U)<\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Net weight (kg)<\/td>\n<td style=\"text-align: center;\" width=\"425\">15<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"659\"><strong>STANDARDS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Safety<\/td>\n<td style=\"text-align: center;\" width=\"425\">IEC\/EN62040-1,IEC\/EN60950-1<\/td>\n<\/tr>\n<tr>\n<td width=\"235\">EMC<\/td>\n<td style=\"text-align: center;\" width=\"425\">IEC\/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,<\/p>\n<p>IEC61000-4-5,IEC61000-4-6,IEC61000-4-8<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"659\"><strong>CABINET BATTERY<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"235\">N\u00b0 of batteries<\/td>\n<td style=\"text-align: center;\" width=\"425\">16pcs max (7\/9Ah)<\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Dimensions W\u00d7H\u00d7D (mm)<\/td>\n<td style=\"text-align: center;\" width=\"425\">440*132*520 (3U)<\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Net weight (kg)<\/td>\n<td style=\"text-align: center;\" width=\"425\">50<\/td>\n<\/tr>\n<tr>\n<td width=\"235\">Remarks<\/td>\n<td style=\"text-align: center;\" width=\"425\">Hot-swappable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>FLX \u2013 19\u2033\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA On-line double conversion with Digital Signal Processor (DSP) digital control technology. Among the main features that make this series highly efficient we point out: High PF in input and output Wide range of input tolerance (energy saving) Eco Mode (Economic operation mode) [&hellip;]<\/p>\n","protected":false},"featured_media":14765,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[692,221],"product_tag":[253,329,296,237,1690,1691,603,273,328],"class_list":["post-12530","product","type-product","status-publish","has-post-thumbnail","product_cat-single-phase-uninterruptible-power-supplies","product_cat-uninterruptible-power-supplies","product_tag-black-out","product_tag-double-conversion-ups-2","product_tag-energy-reserve","product_tag-accumulo-en","product_tag-online-ups","product_tag-sine-wave-ups","product_tag-single-phase-ups","product_tag-uninterruptible-power-supply-2","product_tag-ups","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","featured","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FLX - 19&quot;\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA - K-factor<\/title>\n<meta name=\"description\" content=\"FLX Rack\/Tower convertible single-phase UPS (1-10kVA). Online double conversion technology with DSP control, Eco Mode, and maximum server protection.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FLX - 19&quot;\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA - K-factor\" \/>\n<meta property=\"og:description\" content=\"FLX Rack\/Tower convertible single-phase UPS (1-10kVA). Online double conversion technology with DSP control, Eco Mode, and maximum server protection.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-24T06:33:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/05\/ft1280-flx_01.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/gruppi-statici-di-continuita-it\\\/gruppi-statici-di-continuita-monofase\\\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/gruppi-statici-di-continuita-it\\\/gruppi-statici-di-continuita-monofase\\\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\\\/\",\"name\":\"FLX - 19\\\"\\\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/gruppi-statici-di-continuita-it\\\/gruppi-statici-di-continuita-monofase\\\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/gruppi-statici-di-continuita-it\\\/gruppi-statici-di-continuita-monofase\\\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/ft1280-flx_01.jpg\",\"datePublished\":\"2024-02-15T14:38:42+00:00\",\"dateModified\":\"2026-04-24T06:33:54+00:00\",\"description\":\"FLX Rack\\\/Tower convertible single-phase UPS (1-10kVA). Online double conversion technology with DSP control, Eco Mode, and maximum server protection.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/gruppi-statici-di-continuita-it\\\/gruppi-statici-di-continuita-monofase\\\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/gruppi-statici-di-continuita-it\\\/gruppi-statici-di-continuita-monofase\\\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/gruppi-statici-di-continuita-it\\\/gruppi-statici-di-continuita-monofase\\\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/ft1280-flx_01.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/ft1280-flx_01.jpg\",\"width\":1280,\"height\":720},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/gruppi-statici-di-continuita-it\\\/gruppi-statici-di-continuita-monofase\\\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FLX &#8211; 19&#8243;\\\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"ELECTRONICS MADE EASY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FLX - 19\"\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA - K-factor","description":"FLX Rack\/Tower convertible single-phase UPS (1-10kVA). Online double conversion technology with DSP control, Eco Mode, and maximum server protection.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/","og_locale":"en_US","og_type":"article","og_title":"FLX - 19\"\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA - K-factor","og_description":"FLX Rack\/Tower convertible single-phase UPS (1-10kVA). Online double conversion technology with DSP control, Eco Mode, and maximum server protection.","og_url":"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/","og_site_name":"K-factor","article_modified_time":"2026-04-24T06:33:54+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/05\/ft1280-flx_01.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/","url":"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/","name":"FLX - 19\"\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/05\/ft1280-flx_01.jpg","datePublished":"2024-02-15T14:38:42+00:00","dateModified":"2026-04-24T06:33:54+00:00","description":"FLX Rack\/Tower convertible single-phase UPS (1-10kVA). Online double conversion technology with DSP control, Eco Mode, and maximum server protection.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/05\/ft1280-flx_01.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/05\/ft1280-flx_01.jpg","width":1280,"height":720},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/shop\/gruppi-statici-di-continuita-it\/gruppi-statici-di-continuita-monofase\/flx-ups-rack-19-tower-online-doppia-conversione-onda-sinusoidale-da-1kva-a-10kva\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"PRODUCTS","item":"https:\/\/www.kfactor.it\/en\/shop\/"},{"@type":"ListItem","position":2,"name":"FLX &#8211; 19&#8243;\/TOWER RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1KVA TO 10KVA"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"ELECTRONICS MADE EASY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product\/12530","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media\/14765"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media?parent=12530"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_brand?post=12530"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_cat?post=12530"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_tag?post=12530"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}