{"id":12532,"date":"2024-02-16T12:38:36","date_gmt":"2024-02-16T11:38:36","guid":{"rendered":"https:\/\/www.kfactor.it\/?post_type=product&#038;p=12532"},"modified":"2026-03-23T11:33:54","modified_gmt":"2026-03-23T10:33:54","slug":"nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/","title":{"rendered":"NRG-MED &#8211; MEDICAL UPS with ON-LINE technology safety and security of medical devices"},"content":{"rendered":"<p><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed01.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2700 size-full\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed01.jpg\" alt=\"NRG-MED - UPS MEDICALI con tecnologia ON-LINE sicurezza e protezione dei dispositivi medici\" width=\"468\" height=\"312\" srcset=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed01.jpg 468w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed01-350x233.jpg 350w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed01-400x267.jpg 400w\" sizes=\"auto, (max-width: 468px) 100vw, 468px\" \/><\/a><\/p>\n<p>Today&#8217;s healthcare provides fast, flawless diagnoses and precise patient treatments thanks to professional equipment of sophisticated technology.<\/p>\n<p>Highly developed devices such as clinical analyzers, image systems, patient monitoring devices, cardiac devices, surgical lasers and other delicate electronic systems, are extremely susceptible to damage and interference due to poor power quality problems.<\/p>\n<p>When this happens, it is impossible to have precise and accurate diagnoses and treatments.<\/p>\n<p>The NRG-MED series is a professional UPS line totally dedicated to powering critical medical devices, where network interruptions can generate inconveniences during specific treatments.<\/p>\n<p>Thanks to an accurate and precise design, the NRG-MED are defined as medical UPS of excellent quality with the following key characteristics:<\/p>\n<p><strong>Double toroidal isolation transformer <\/strong><strong>designed to ensure real safety to the connected load, with 6000V of isolation from the network and 4000V from the output of the unit.<\/strong><\/p>\n<ul>\n<li><strong>Electrostatic shield <\/strong><strong>designed to reduce electrostatic charges deriving from the network<\/strong><\/li>\n<li><strong>Low-voltage <\/strong><strong>electronics to ensure high safety for operators<\/strong><\/li>\n<li><strong>Medical filters<\/strong><\/li>\n<li><strong>By-pass <\/strong><strong>with galvanic isolation to avoid direct connection of the load with the network<\/strong><\/li>\n<\/ul>\n<p>And, also<\/p>\n<ul>\n<li>Dedicated chargers designed to maintain battery efficiency at the highest levels allow an increase in autonomy according to customer needs.<\/li>\n<li>The choice of batteries is focused on high-performance batteries with 10 years of expected life.<\/li>\n<li>Efficiency is controlled via an automatic and manual battery test.<\/li>\n<li>An easy-to-use front panel with blue LCD and LED display allows simple control of the main functions of the unit.<\/li>\n<\/ul>\n<p><strong>MAIN FEATURES<\/strong><\/p>\n<p><strong>ON LINE TECHNOLOGY<\/strong><\/p>\n<p>The choice to work with an ON-LINE technology allows to have continuity to the load without switching times in case of black-out.<br \/>\n<strong>NETWORK ISOLATION<\/strong><\/p>\n<p>This technology always provides current filtered by network disturbances.<\/p>\n<p>A double toroidal isolation transformer provides total load protection.<\/p>\n<p>6000V of galvanic isolation input and 4000V output allow high protection even<\/p>\n<p>to the electronic section.<\/p>\n<p><strong>ELECTROSTATIC PROTECTION <\/strong><\/p>\n<p>Maximum protection against electrostatic discharge from the network.<\/p>\n<p>Key feature to safeguard the safety of operators during the operation of the unit thanks to non-hazardous voltages in the electronic section.<\/p>\n<p><strong>MEDICAL FILTERS<\/strong><\/p>\n<p>RFI medical filters designed at the request of specific UPSs able to reduce incoming and outgoing disturbances.<\/p>\n<p><strong>ISOLATED BY-PASS OPERATION<\/strong><\/p>\n<p>In By-pass mode, 6000V of galvanic isolation is maintained to avoid direct connection of the load with the network.<\/p>\n<p><strong>QUICK CHARGER<\/strong><\/p>\n<p>Special battery chargers on board the UPS, are designed to maintain the efficiency of the batteries at the highest levels and to be able to have the possibility to increase the autonomy according to customer requests.<\/p>\n<p><strong>BATTERY EFFICIENCY CONTROL<\/strong><\/p>\n<p>The status of the batteries can be easily checked at any time through a black button located on the front panel of the unit.<\/p>\n<p>Periodically, however, the unit automatically performs a battery test.<\/p>\n<p><strong>BATTERIES 10 YEARS EXPECTED LIFE<\/strong><\/p>\n<p>Hermetic lead batteries with 99% gas recombination with 10 years of expected life.<\/p>\n<p><strong>UNIT MONITORING<\/strong><\/p>\n<p>LEDs positioned on the front panel for easy monitoring of unit functions<\/p>\n<p>BLUE LCD DISPLAY V+I output \u00e0<\/p>\n<p>Remote free contacts for remote control<\/p>\n<p><strong>ISOLATION CONTROLLER (OPTIONAL)<\/strong><\/p>\n<p>Each unit can be supplied with an on-board isolation controller, so you can monitor system isolation when an IT regime is required.<\/p>\n<p><strong>SPECIAL MECHANICAL TREATMENTS<\/strong><\/p>\n<p>TROPICALIZATION<\/p>\n<p>Treatment dedicated to protecting electronic boards in case of high humidity and high temperatures.<\/p>\n<p>ANTI-VIBRATION Mechanical treatment performed with a special paste\/glue against vibrations.<\/p>\n<p><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed02.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" alignleft wp-image-2702\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed02.jpg\" alt=\"NRG-MED - UPS MEDICALI con tecnologia ON-LINE sicurezza e protezione dei dispositivi medici\" width=\"296\" height=\"91\" srcset=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed02.jpg 555w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed02-350x108.jpg 350w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ups-nrgmed02-400x123.jpg 400w\" sizes=\"auto, (max-width: 296px) 100vw, 296px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<table width=\"720\">\n<tbody>\n<tr>\n<td width=\"275\"><strong>MODEL<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"125\"><strong>NRG-MED02<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"112\"><strong>NRG-MED04<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"104\"><strong>NRG-MED06<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"105\"><strong>NRG-MED09<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>Output current on linear load<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"125\">1.9 A<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"112\">3.9 A<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"104\">5.8 A<\/td>\n<td style=\"text-align: center;\" width=\"105\">9.1 A<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>POWER<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"125\">400W<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"112\">900W<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"104\">1350W<\/td>\n<td style=\"text-align: center;\" width=\"105\">2100W<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>Peak power for 5&#8243;<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"125\">800W<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"112\">1400W<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"104\">2200W<\/td>\n<td style=\"text-align: center;\" width=\"105\">3200W<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>INPUT DATA<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\"><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Tension<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">230Vac single-phase \u00b110%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Frequency<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">50Hz \u00b15% (max speed 0.5Hz\/sec)<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Network isolation<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">6000V galvanic isolation through toroidal transformer with electrostatic shield between primary and secondary<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Protections<\/td>\n<td style=\"text-align: center;\" width=\"111\">Auto. input 6 A<\/td>\n<td style=\"text-align: center;\" colspan=\"5\" width=\"223\">Automatic input 10 A<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"111\">Autom.ingress 16 A<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Connections<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Integrated Schuko cable<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Limit-in<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Aboard<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>OUTPUT DATA<\/strong><\/td>\n<td colspan=\"8\" width=\"445\"><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Tension<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">230Vac single-phase<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Frequency<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">50Hz \u00b10.01% (faulty network)<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Load isolation<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">4000V galvanic isolation through toroidal transformer<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Sine wave<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Generated by microprocessor<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Soft start<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Aboard<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Connections<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">1 multistandard socket<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Electrical protection<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Life-saving differential 30mA (isolation controller + automatic output on request)<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Electronic protection<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Overload \u2013 short circuit<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Linear load distortion<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">&lt; 5%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Nonlinear load distortion<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">&lt; 8%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Static voltage variation<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">&lt; 1%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Dynamic voltage variation<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">\u00b13%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">By-pass<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Static by-pass connected to the input toroidal transformer with galvanic isolation<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>BATTERIES<\/strong><\/td>\n<td colspan=\"8\" width=\"445\"><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Tension<\/td>\n<td style=\"text-align: center;\" width=\"111\">24V<\/td>\n<td style=\"text-align: center;\" colspan=\"7\" width=\"334\">48V<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Typology<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Hermetic lead<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Capacity<\/td>\n<td style=\"text-align: center;\" width=\"111\">2 x 12V 9Ah<\/td>\n<td style=\"text-align: center;\" colspan=\"5\" width=\"223\">4 x 12V 9Ah<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"111\">8 x 12V 9Ah<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Expected life<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">10 years<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Battery fuses<\/td>\n<td style=\"text-align: center;\" colspan=\"6\" width=\"334\">32AT<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"111\">80AT<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Max charging current<\/td>\n<td style=\"text-align: center;\" width=\"111\">0.6 A<\/td>\n<td style=\"text-align: center;\" colspan=\"5\" width=\"223\">1.2 A<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"111\">1.8 A<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Autonomy with 70% of the load<\/td>\n<td style=\"text-align: center;\" colspan=\"4\" width=\"223\">20&#8242;<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"111\">12&#8242;<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"111\">15&#8242;<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">TECHNOLOGY<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">On line double conversion with PWM microprocessor<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Inverter<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Low voltage<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Intervention time<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">ZERO<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Inverter efficiency<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">&gt;82%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" width=\"720\"><strong>ENVIRONMENTAL CONDITIONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Storage temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">-10\u00b0C : +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Working temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">0\u00b0C : +40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Noise level at 1m.<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"118\">27dB<\/td>\n<td style=\"text-align: center;\" colspan=\"6\" width=\"327\">32dB<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" width=\"720\"><strong>REPORTS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Optics and acoustics<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Network on \u2013 battery mode \u2013 low batteries \u2013 critical temperature \u2013 overtemperature \u2013 overcharge \u2013 by-pass mode \u2013 lack of insulation \u2013 battery test<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Remote Contacts<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">Remote on\/off \u2013 lack of network \u2013 low batteries \u2013 GENERAL ALARM (critical temperature, stop temperature, overload, short circuit, lack of insulation (if any)), battery test<\/td>\n<\/tr>\n<tr>\n<td colspan=\"9\" width=\"720\"><strong>CARPENTRY<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Floor version mm<\/td>\n<td style=\"text-align: center;\" colspan=\"8\" width=\"445\">243x585x482h<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Weight (kg)<\/td>\n<td style=\"text-align: center;\" width=\"111\">30<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"111\">53<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"111\">56<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"111\">70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"720\">\n<tbody>\n<tr>\n<td width=\"275\"><strong>MODEL<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"148\"><strong>NRG-MED12<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"148\"><strong>NRG-MED15<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"148\"><strong>NRG-MED18<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>Output current on linear load<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"148\">13 A<\/td>\n<td style=\"text-align: center;\" width=\"148\">14.6 A<\/td>\n<td style=\"text-align: center;\" width=\"148\">17.6 A<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>POWER<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"148\">3000W<\/td>\n<td style=\"text-align: center;\" width=\"148\">3375W<\/td>\n<td style=\"text-align: center;\" width=\"148\">4050W<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>Peak power for 5&#8243;<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"148\">4000W<\/td>\n<td style=\"text-align: center;\" width=\"148\">5500W<\/td>\n<td style=\"text-align: center;\" width=\"148\">6000W<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>INPUT DATA<\/strong><\/td>\n<td colspan=\"3\" width=\"445\"><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Tension<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">230Vac single-phase \u00b110%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Frequency<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">50Hz \u00b15% (max speed 0.5Hz\/sec)<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Network isolation<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">6000V galvanic isolation through toroidal transformer with electrostatic shield between primary and secondary<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Protections<\/td>\n<td style=\"text-align: center;\" width=\"148\">Automatic input 16 A<\/td>\n<td style=\"text-align: center;\" width=\"148\">Automatic input 20 A<\/td>\n<td style=\"text-align: center;\" width=\"148\">Automatic input 25 A<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Connections<\/td>\n<td style=\"text-align: center;\" width=\"148\">Integrated Schuko cable<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"297\">Terminal block<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Limit-in<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Aboard<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>OUTPUT DATA<\/strong><\/td>\n<td colspan=\"3\" width=\"445\"><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Tension<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">230Vac single-phase<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Frequency<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">50Hz \u00b10.01% (faulty network)<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Load isolation<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">4000V galvanic isolation through toroidal transformer<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Sine wave<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Generated by microprocessor<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Soft start<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Aboard<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Connections<\/td>\n<td style=\"text-align: center;\" width=\"148\">1 multistandard socket<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"297\">Terminal block<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Electrical protection<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Life-saving differential 30mA (isolation controller + automatic output on request)<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Electronic protection<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Overload \u2013 short circuit<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Linear load distortion<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">&lt; 5%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Nonlinear load distortion<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">&lt; 8%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Static voltage variation<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">&lt; 1%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Dynamic voltage variation<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">\u00b13%<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">By-pass<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Static by-pass connected to the input toroidal transformer with galvanic isolation<\/td>\n<\/tr>\n<tr>\n<td width=\"275\"><strong>BATTERIES<\/strong><\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\"><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Tension<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">48V<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Typology<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Hermetic lead<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Capacity<\/td>\n<td style=\"text-align: center;\" width=\"148\">8 x 12V 9Ah<\/td>\n<td style=\"text-align: center;\" width=\"148\">4 x 12V 24Ah<\/td>\n<td style=\"text-align: center;\" width=\"148\">4 x 12V 33Ah<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Expected life<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">10 years<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Battery fuses<\/td>\n<td style=\"text-align: center;\" width=\"148\">22&#215;58 80AT<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"297\">22&#215;58 100AT<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Max charging current<\/td>\n<td style=\"text-align: center;\" width=\"148\">1.8 A<\/td>\n<td style=\"text-align: center;\" width=\"148\">5.5 A<\/td>\n<td style=\"text-align: center;\" width=\"148\">5.5 A<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Autonomy with 70% of the load<\/td>\n<td style=\"text-align: center;\" width=\"148\">8&#8242;<\/td>\n<td style=\"text-align: center;\" width=\"148\">12&#8242;<\/td>\n<td style=\"text-align: center;\" width=\"148\">12&#8242;<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">TECHNOLOGY<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">On line double conversion with PWM microprocessor<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Inverter<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Low voltage<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Intervention time<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">ZERO<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Inverter efficiency<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">&gt;82%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"720\"><strong>ENVIRONMENTAL CONDITIONS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Storage temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">-10\u00b0C : +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Working temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">0\u00b0C : +40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Noise level at 1m.<\/td>\n<td style=\"text-align: center;\" width=\"148\">32dB<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"297\">37dB<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"720\"><strong>REPORTS<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Optics and acoustics<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Network on \u2013 battery mode \u2013 low batteries \u2013 critical temperature \u2013 overtemperature \u2013 overcharge \u2013 by-pass mode \u2013 lack of insulation \u2013 battery test<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Remote Contacts<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"445\">Remote on\/off \u2013 lack of network \u2013 low batteries \u2013 GENERAL ALARM (critical temperature, stop temperature, overload, short circuit, lack of insulation (if any)), battery test<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" width=\"720\"><strong>CARPENTRY<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Floor version mm<\/td>\n<td style=\"text-align: center;\" width=\"148\">243x585x482h<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"297\">355&#215;782+53x765h<\/td>\n<\/tr>\n<tr>\n<td width=\"275\">Weight (kg)<\/td>\n<td style=\"text-align: center;\" width=\"148\">80<\/td>\n<td style=\"text-align: center;\" width=\"148\">70+60<\/td>\n<td style=\"text-align: center;\" width=\"148\">77+70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Today&#8217;s healthcare provides fast, flawless diagnoses and precise patient treatments thanks to professional equipment of sophisticated technology. Highly developed devices such as clinical analyzers, image systems, patient monitoring devices, cardiac devices, surgical lasers and other delicate electronic systems, are extremely susceptible to damage and interference due to poor power quality problems. When this happens, it [&hellip;]<\/p>\n","protected":false},"featured_media":13209,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[692,221],"product_tag":[275,330,333],"class_list":["post-12532","product","type-product","status-publish","has-post-thumbnail","product_cat-single-phase-uninterruptible-power-supplies","product_cat-uninterruptible-power-supplies","product_tag-medical-environment-ups","product_tag-ups-for-medical-use","product_tag-ups-uso-medico-en","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","outofstock","featured","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>NRG-MED - MEDICAL UPS with ON-LINE technology safety and security of medical devices - K-factor<\/title>\n<meta name=\"description\" content=\"NRG-MED single-phase medical UPS with online double conversion technology. Dual toroidal transformer and extreme galvanic isolation for maximum clinical safety.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NRG-MED - MEDICAL UPS with ON-LINE technology safety and security of medical devices - K-factor\" \/>\n<meta property=\"og:description\" content=\"NRG-MED single-phase medical UPS with online double conversion technology. Dual toroidal transformer and extreme galvanic isolation for maximum clinical safety.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-23T10:33:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/05\/ft1280-nrg-med02.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\\\/\",\"name\":\"NRG-MED - MEDICAL UPS with ON-LINE technology safety and security of medical devices - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/ft1280-nrg-med02.jpg\",\"datePublished\":\"2024-02-16T11:38:36+00:00\",\"dateModified\":\"2026-03-23T10:33:54+00:00\",\"description\":\"NRG-MED single-phase medical UPS with online double conversion technology. Dual toroidal transformer and extreme galvanic isolation for maximum clinical safety.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/ft1280-nrg-med02.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/ft1280-nrg-med02.jpg\",\"width\":1280,\"height\":720,\"caption\":\"ups medicale\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/single-phase-uninterruptible-power-supplies\\\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"NRG-MED &#8211; MEDICAL UPS with ON-LINE technology safety and security of medical devices\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"ELECTRONICS MADE EASY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NRG-MED - MEDICAL UPS with ON-LINE technology safety and security of medical devices - K-factor","description":"NRG-MED single-phase medical UPS with online double conversion technology. Dual toroidal transformer and extreme galvanic isolation for maximum clinical safety.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/","og_locale":"en_US","og_type":"article","og_title":"NRG-MED - MEDICAL UPS with ON-LINE technology safety and security of medical devices - K-factor","og_description":"NRG-MED single-phase medical UPS with online double conversion technology. Dual toroidal transformer and extreme galvanic isolation for maximum clinical safety.","og_url":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/","og_site_name":"K-factor","article_modified_time":"2026-03-23T10:33:54+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/05\/ft1280-nrg-med02.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/","url":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/","name":"NRG-MED - MEDICAL UPS with ON-LINE technology safety and security of medical devices - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/05\/ft1280-nrg-med02.jpg","datePublished":"2024-02-16T11:38:36+00:00","dateModified":"2026-03-23T10:33:54+00:00","description":"NRG-MED single-phase medical UPS with online double conversion technology. Dual toroidal transformer and extreme galvanic isolation for maximum clinical safety.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/05\/ft1280-nrg-med02.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/05\/ft1280-nrg-med02.jpg","width":1280,"height":720,"caption":"ups medicale"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/single-phase-uninterruptible-power-supplies\/nrg-med-medical-ups-with-on-line-technology-safety-and-security-of-medical-devices\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"PRODUCTS","item":"https:\/\/www.kfactor.it\/en\/shop\/"},{"@type":"ListItem","position":2,"name":"NRG-MED &#8211; MEDICAL UPS with ON-LINE technology safety and security of medical devices"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"ELECTRONICS MADE EASY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product\/12532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media\/13209"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media?parent=12532"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_brand?post=12532"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_cat?post=12532"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_tag?post=12532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}