{"id":13936,"date":"2024-10-26T12:28:01","date_gmt":"2024-10-26T10:28:01","guid":{"rendered":"https:\/\/www.kfactor.it\/?post_type=product&#038;p=13936"},"modified":"2026-03-23T12:24:35","modified_gmt":"2026-03-23T11:24:35","slug":"pla-ups-three-phase-double-conversion-sine-wave-form-10-to-200kva-copia","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/pla-ups-three-phase-double-conversion-sine-wave-form-10-to-200kva-copia\/","title":{"rendered":"NTL &#8211; MODULAR UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, RACK MODULES form 50 to 600KVA"},"content":{"rendered":"<p>The new NTL range uses the modular 19&#8243; rack drawer technology and was created to guarantee the best quality and reliability of service.<\/p>\n<p>Each power module works in a &#8220;decentralized parallel&#8221; with the others, and the complete system autonomously divides the input load.<\/p>\n<p>In the event of a failure of one of the modules, it is automatically excluded (decentralized parallel), thus ensuring a seamless power supply with the remaining modules.<\/p>\n<p>Among the strengths of the NTL modular range we have a system efficiency &gt; 95% (high efficiency), a reduction in repair times and service costs of less than 30 &#8216;and the centralization of the static switching system that gives greater guarantees.<\/p>\n<p>We recommend the use of the NTL series for Data Centers, Banks, Hospitals, Airports, Emergency Lights<\/p>\n<p>and any Industrial application.<\/p>\n<p>Display LCD touch screen<\/p>\n<p><strong>MAIN FEATURES<\/strong><\/p>\n<ul>\n<li>Input power factor 0.99<\/li>\n<li>Harmonic input distortion &lt;2%<\/li>\n<li>Centralized control display, which allows you to check at any time, (even by removing a single module) the actual power and data related to all modules.<\/li>\n<li>EPO function<\/li>\n<li>Display LCD touch screen<\/li>\n<\/ul>\n<p><strong>COMMUNICATION PORTS:<\/strong><\/p>\n<ul>\n<li>1x RS232 \u2013 2x Rs485<\/li>\n<li>1x MODBUS PORT<\/li>\n<li>1x CLEAN CONTACTS<\/li>\n<li>2x COMMUNICATION SLOT<\/li>\n<\/ul>\n<p>The modules use the latest generation of DSP microprocessors, in this way the components are reduced and reliability is increased.<\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">FRAME (Cabinet type)<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">150<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">250<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">400<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">600<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"4\">Capacity<\/td>\n<td style=\"text-align: center;\">System (KVA)<\/td>\n<td style=\"text-align: center;\">50~100<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">50~150<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">50~200<\/td>\n<td style=\"text-align: center;\">50~250<\/td>\n<td style=\"text-align: center;\">50~300<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">50~400<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">50~500<\/td>\n<td style=\"text-align: center;\">50~600<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Module (KVA)<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">50<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Module (KW)<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">2<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">3<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">4<\/td>\n<td style=\"text-align: center;\">5<\/td>\n<td style=\"text-align: center;\">6<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">8<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">12<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Maximum Number of Modules<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">3<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">5<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">8<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">12<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"7\">Input<\/td>\n<td style=\"text-align: center;\">Phases<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">3 Phases + Neutral + GND<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Rated Voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">380\/400\/415Vac<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Voltage Range<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">138~485Vac<\/p>\n<p>\u25c6At 40\u00b0C: UPS works at full load when voltage is within 323 and 485 Vac and is derated when voltage is within 323 and 138 Vac.<\/p>\n<p>\u25c6At 30\u00b0C: UPS works at full load when voltage is within 305 and 485 Vac and is derated when voltage is within 305 and 138 Vac.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Frequency Range<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">40Hz-70Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Power factor<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">\u22650.99<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Bypass Voltage Range<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">\u22643% (100% non-linear load)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Genset input<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">Max voltage: 220V: +25 % (optional +10%, +15%, +20%)<\/p>\n<p>230V: +20 % (optional +10%, +15%)<\/p>\n<p>240V: +15 % (optional +10%)<\/p>\n<p>Min Voltage: -45 % (optional -10%, -20%, -30%)<\/p>\n<p>Frequency protection range: \u00b110%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"9\">Output<\/td>\n<td style=\"text-align: center;\">Phases<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">3 Phase + Neutral + GND<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Rated Voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">380\/400\/415Vac (factory setting)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Power factor<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">1.0<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Voltage Regulation<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Frequency<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">\u00b11%\/\u00b12%\/\u00b14%\/\u00b15%\/\u00b110% of rated frequency (optional)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Battery mode frequency<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">(50\/60\u00b10.1) Hz<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Crest factor<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">3:1<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"2\">THD<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">\u22642% linear load<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"13\">\u22644% non-linear load<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"2\">Battery<\/td>\n<td style=\"text-align: center;\">Voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">Optional Voltage:<\/p>\n<p>\u00b1180\/192\/\u00b1204\/\u00b1216\/\u00b1228\/\u00b1240\/\u00b1252\/\u00b1264\/\u00b1276\/\u00b1288\/\u00b1300Vdc<\/p>\n<p>(30\/32\/34\/36\/38\/40\/42\/44\/46\/48\/50pcs optional)<\/p>\n<p>360Vdc~600Vdc (30~50 pcs, 36 ~50 pcs no derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Load current on each module (A) max.<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">20A<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">Transfer time<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">From grid to batteries: 0ms from grid to bypass: 0ms<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"7\">Protections<\/td>\n<td style=\"text-align: center;\">Overload<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">Inverter overload capacity:<\/p>\n<p>\u25c6 105% &lt; load \u2264 110%: transfer to bypass mode after 60 min<\/p>\n<p>\u25c6 110% &lt; load \u2264 125%: transfer to bypass mode after 10 min<\/p>\n<p>\u25c6 125% &lt; load \u2264 150%: transfer to bypass mode after 1 min<\/p>\n<p>Bypass overload capacity:<\/p>\n<p>\u25c6 Temperature \u2264 30\u00b0C, load \u2264 135%: long time<\/p>\n<p>\u25c6 Temperature \u2264 40\u00b0C, load \u2264 125%: long time<\/p>\n<p>\u25c6 1000% load: 100 ms<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Short circuit<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">Involves entire system<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Overheating<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">Normal Mode: transfer to Bypass,<\/p>\n<p>Battery mode: turn off UPS immediately<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Self-diagnosis<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">At start-up and through software<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">EPO (optional)<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">Switches immediately the unit<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Battery<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">Advanced battery management<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Noise suppression<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">According to EN62040-2<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">Communication Interface<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">RS232, RS485, LBS, Parallel, SNMP card (optional), Relay card (optional)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"4\">Environment<\/td>\n<td style=\"text-align: center;\">Operating temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">0\u00b0C~40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Storage temperature<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">-25\u00b0C~55\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Humidity<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">0%~95% non-condensing<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Altitude<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">&lt; 1500m<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"3\">Display<\/td>\n<td style=\"text-align: center;\">Acoustic and display<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">Grid Failure, Low Battery, Overload, System Failure<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">LED<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">UPS Failure, Alarms and Normal Operation<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Data<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">Input voltage, input frequency, output voltage, output frequency, load percentage, battery voltage, parameter set, event history&#8230;<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" rowspan=\"4\">Various<\/td>\n<td style=\"text-align: center;\">FRAME size<\/p>\n<p>(WxDxH) mm<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">600x850x1200<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">600x850x1600<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">600x850x2000<\/td>\n<td style=\"text-align: center;\" colspan=\"3\">1200x850x2000<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">MODULE size<\/p>\n<p>(WxDxH) mm<\/td>\n<td style=\"text-align: center;\" colspan=\"12\">440x320x130<\/td>\n<td style=\"text-align: center;\"><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Cabinet weight (Kg)<\/td>\n<td style=\"text-align: center;\">145<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">155<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">250<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">265<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">280<\/td>\n<td style=\"text-align: center;\">360<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">480<\/td>\n<td style=\"text-align: center;\">540<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Module weight Kg)<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">34<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"2\">Safety standards<\/td>\n<td style=\"text-align: center;\" colspan=\"13\">CE,EN\/IEC 62040-3,EN\/IEC 62040-1-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>The new NTL range uses the modular 19&#8243; rack drawer technology and was created to guarantee the best quality and reliability of service. Each power module works in a &#8220;decentralized parallel&#8221; with the others, and the complete system autonomously divides the input load. In the event of a failure of one of the modules, it [&hellip;]<\/p>\n","protected":false},"featured_media":13940,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[694,221],"product_tag":[274,329,276,277],"class_list":["post-13936","product","type-product","status-publish","has-post-thumbnail","product_cat-three-phase-static-uninterruptible-power-supplies-en","product_cat-uninterruptible-power-supplies","product_tag-double-conversion-ups","product_tag-double-conversion-ups-2","product_tag-three-phase-on-line-ups","product_tag-uninterruptible-power-supply-3","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>NTL - MODULAR UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, RACK MODULES form 50 to 600KVA - K-factor<\/title>\n<meta name=\"description\" content=\"NTL series modular three-phase UPS (10-520kVA). Online double conversion technology, maximum redundancy, and scalability for data centers and critical infrastructures.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NTL - MODULAR UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, RACK MODULES form 50 to 600KVA - K-factor\" \/>\n<meta property=\"og:description\" content=\"NTL series modular three-phase UPS (10-520kVA). Online double conversion technology, maximum redundancy, and scalability for data centers and critical infrastructures.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-23T11:24:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-ntl01.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/es\\\/shop\\\/sistemas-de-alimentacion-ininterrumpida-sai-ups\\\/sai-trifasicos\\\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/es\\\/shop\\\/sistemas-de-alimentacion-ininterrumpida-sai-ups\\\/sai-trifasicos\\\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\\\/\",\"name\":\"NTL - MODULAR UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, RACK MODULES form 50 to 600KVA - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/es\\\/shop\\\/sistemas-de-alimentacion-ininterrumpida-sai-ups\\\/sai-trifasicos\\\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/es\\\/shop\\\/sistemas-de-alimentacion-ininterrumpida-sai-ups\\\/sai-trifasicos\\\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-ntl01.jpg\",\"datePublished\":\"2024-10-26T10:28:01+00:00\",\"dateModified\":\"2026-03-23T11:24:35+00:00\",\"description\":\"NTL series modular three-phase UPS (10-520kVA). Online double conversion technology, maximum redundancy, and scalability for data centers and critical infrastructures.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/es\\\/shop\\\/sistemas-de-alimentacion-ininterrumpida-sai-ups\\\/sai-trifasicos\\\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/es\\\/shop\\\/sistemas-de-alimentacion-ininterrumpida-sai-ups\\\/sai-trifasicos\\\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/es\\\/shop\\\/sistemas-de-alimentacion-ininterrumpida-sai-ups\\\/sai-trifasicos\\\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-ntl01.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-ntl01.jpg\",\"width\":1280,\"height\":720,\"caption\":\"UPS MODULARE RACK\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/es\\\/shop\\\/sistemas-de-alimentacion-ininterrumpida-sai-ups\\\/sai-trifasicos\\\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"NTL &#8211; MODULAR UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, RACK MODULES form 50 to 600KVA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"ELECTRONICS MADE EASY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NTL - MODULAR UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, RACK MODULES form 50 to 600KVA - K-factor","description":"NTL series modular three-phase UPS (10-520kVA). Online double conversion technology, maximum redundancy, and scalability for data centers and critical infrastructures.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/","og_locale":"en_US","og_type":"article","og_title":"NTL - MODULAR UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, RACK MODULES form 50 to 600KVA - K-factor","og_description":"NTL series modular three-phase UPS (10-520kVA). Online double conversion technology, maximum redundancy, and scalability for data centers and critical infrastructures.","og_url":"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/","og_site_name":"K-factor","article_modified_time":"2026-03-23T11:24:35+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-ntl01.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/","url":"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/","name":"NTL - MODULAR UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, RACK MODULES form 50 to 600KVA - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-ntl01.jpg","datePublished":"2024-10-26T10:28:01+00:00","dateModified":"2026-03-23T11:24:35+00:00","description":"NTL series modular three-phase UPS (10-520kVA). Online double conversion technology, maximum redundancy, and scalability for data centers and critical infrastructures.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-ntl01.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-ntl01.jpg","width":1280,"height":720,"caption":"UPS MODULARE RACK"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/es\/shop\/sistemas-de-alimentacion-ininterrumpida-sai-ups\/sai-trifasicos\/ntl-ups-trifase-modulare-doppia-conversione-onda-sinusoidale-da-10-a-520kva\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"PRODUCTS","item":"https:\/\/www.kfactor.it\/en\/shop\/"},{"@type":"ListItem","position":2,"name":"NTL &#8211; MODULAR UPS THREE PHASE, DOUBLE CONVERSION, SINE WAVE, RACK MODULES form 50 to 600KVA"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"ELECTRONICS MADE EASY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product\/13936","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media\/13940"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media?parent=13936"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_brand?post=13936"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_cat?post=13936"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_tag?post=13936"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}