{"id":14522,"date":"2025-04-29T19:08:05","date_gmt":"2025-04-29T17:08:05","guid":{"rendered":"https:\/\/www.kfactor.it\/?post_type=product&#038;p=14522"},"modified":"2026-05-21T15:12:05","modified_gmt":"2026-05-21T13:12:05","slug":"tmib249-267-single-phase-isolation-transformers-for-for-hifi-professional-a-v-systems-and-laboratory-applications-copia-2","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmib249-267-single-phase-isolation-transformers-for-for-hifi-professional-a-v-systems-and-laboratory-applications-copia-2\/","title":{"rendered":"HI-SOL &#8211; Single and Three Phase 16kV high isolation protection system HI-SOL Series"},"content":{"rendered":"<h3>Single and Three Phase high isolation protection system HI-SOL Series<\/h3>\n<div><\/div>\n<div>Single and three-phase rack wih 16kV isolation transformer<\/div>\n<div>20\/40kA type 1-2 surge suppression<\/div>\n<div>Mcb input output protection<\/div>\n<div>Isolation resitance protection<\/div>\n<div>High-low voltage \u2013 high current protection<\/div>\n<div><\/div>\n<div>IN A VERY TINY SPACE,\u00a0YOUR BROADCAST, PROTECTED<\/div>\n<div><\/div>\n<div><\/div>\n<div>\n<p><strong><u>SINGLE PHASE MODELS<\/u><\/strong><\/p>\n<table style=\"border-collapse: collapse;\">\n<tbody>\n<tr>\n<td><strong>Model<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL02M<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL03M<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL05M<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL06M<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL08M<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL10M<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Type<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">Class I 16KV ISOLATION TRANSFORMER<\/td>\n<\/tr>\n<tr>\n<td>No. of phases<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">Single phase<\/td>\n<\/tr>\n<tr>\n<td>Rated input voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">220-230Vac &#8211; 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Rated power<\/td>\n<td style=\"text-align: center;\"><strong>2kVA<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>3.15kVA<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>5kVA<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>6.3kVA<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>8kVA<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>10kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Screen type<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">Copper earthed screen between the windings<\/td>\n<\/tr>\n<tr>\n<td>Winding construction<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">Copper \/ Copper<\/td>\n<\/tr>\n<tr>\n<td>Rated output voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">220-230Vac &#8211; 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Electric class<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">I<\/td>\n<\/tr>\n<tr>\n<td>Primary protection<\/td>\n<td style=\"text-align: center;\">MCB 8A<\/td>\n<td style=\"text-align: center;\">MCB 15A<\/td>\n<td style=\"text-align: center;\">MCB 20A<\/td>\n<td style=\"text-align: center;\">MCB 25A<\/td>\n<td style=\"text-align: center;\">MCB 32A<\/td>\n<td style=\"text-align: center;\">MCB 40A<\/td>\n<\/tr>\n<tr>\n<td>Secondary protection<\/td>\n<td style=\"text-align: center;\">MCB 8A<\/td>\n<td style=\"text-align: center;\">MCB 15A<\/td>\n<td style=\"text-align: center;\">MCB 20A<\/td>\n<td style=\"text-align: center;\">MCB 25A<\/td>\n<td style=\"text-align: center;\">MCB 32A<\/td>\n<td style=\"text-align: center;\">MCB 40A<\/td>\n<\/tr>\n<tr>\n<td>Input connections<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">2 x 6 sq.mm. terminals + PE<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">2 x 10 sq.mm. terminals + PE<\/td>\n<\/tr>\n<tr>\n<td>Isolation class<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">H<\/td>\n<\/tr>\n<tr>\n<td>Isolation pri\/sec<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">16kV<\/td>\n<\/tr>\n<tr>\n<td>Surge suppressor<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">20kA\/40kA x 2 poles<\/td>\n<\/tr>\n<tr>\n<td>Signals and monitoring<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">Output Digital V-meter \/ A-meter<\/p>\n<p>Output line ON light<\/td>\n<\/tr>\n<tr>\n<td>Auxiliary outlet<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">1 x 10 A Schuko outlet with 10 A protection fuse<\/td>\n<\/tr>\n<tr>\n<td>Isolation monitoring<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">RI-R22 adjustable isolation tester on board<\/td>\n<\/tr>\n<tr>\n<td>Cooling<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">AF controlled by thermal contact<\/td>\n<\/tr>\n<tr>\n<td>Protection<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">IP20<\/td>\n<\/tr>\n<tr>\n<td>Weight kg<\/td>\n<td style=\"text-align: center;\">25<\/td>\n<td style=\"text-align: center;\">30<\/td>\n<td style=\"text-align: center;\">35<\/td>\n<td style=\"text-align: center;\">45<\/td>\n<td style=\"text-align: center;\">60<\/td>\n<td style=\"text-align: center;\">80<\/td>\n<\/tr>\n<tr>\n<td>Dimensions mm<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">19\u201d rack x 4U x depth 350mm<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">19\u201d rack x 5U x depth 400mm<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">19\u201d rack x 5U x depth 460mm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Operating conditions<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">Ambient temperature: 5 \u00f7 25 \u00b0c<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"6\">Ambient humidity percentage: 30 \u00f7 75% RH<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"6\">Altitude: 0 \u00f7 1000m above sea level<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Conditions of storage and transport.<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">Ambient temperature: -40 \u00f7 70 \u00b0 C<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"6\">Ambient humidity percentage: 10 \u00f7 100% RH<\/td>\n<\/tr>\n<tr>\n<td>Standards<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">CEI EN 61558-2-4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><u>THREE PHASE MODELS<\/u><\/strong><\/p>\n<table style=\"border-collapse: collapse;\">\n<tbody>\n<tr>\n<td><strong>Model<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL03T<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL06T<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL08T<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>HI-SOL10T<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Type<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">Class I 16KV ISOLATION TRANSFORMER<\/td>\n<\/tr>\n<tr>\n<td>No. of phases<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">Three phase<\/td>\n<\/tr>\n<tr>\n<td>Rated input voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">380-400Vac &#8211; 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Rated power<\/td>\n<td style=\"text-align: center;\"><strong>3kVA<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>6kVA<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>8kVA<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>10kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Rated input voltage<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">380-400Vac + N &#8211; 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Vector group<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">Dyn11<\/td>\n<\/tr>\n<tr>\n<td>Screen type<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">Copper earthed screen between the windings<\/td>\n<\/tr>\n<tr>\n<td>Winding construction<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">Copper \/ Copper<\/td>\n<\/tr>\n<tr>\n<td>Electric class<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">I<\/td>\n<\/tr>\n<tr>\n<td>Primary protection<\/td>\n<td style=\"text-align: center;\">MCB 3 x 4A<\/td>\n<td style=\"text-align: center;\">MCB 3 x 8A<\/td>\n<td style=\"text-align: center;\">MCB 3 x 10A<\/td>\n<td style=\"text-align: center;\">MCB 15A<\/td>\n<\/tr>\n<tr>\n<td>Secondary protection<\/td>\n<td style=\"text-align: center;\">MCB 3 x 4A<\/td>\n<td style=\"text-align: center;\">MCB 3 x 8A<\/td>\n<td style=\"text-align: center;\">MCB 3 x 10A<\/td>\n<td style=\"text-align: center;\">MCB 15A<\/td>\n<\/tr>\n<tr>\n<td>Input connections<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">2 x 6 sq.mm. terminals + PE<\/td>\n<td style=\"text-align: center;\" colspan=\"2\">2 x 10 sq.mm. terminals + PE<\/td>\n<\/tr>\n<tr>\n<td>Isolation class<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">H<\/td>\n<\/tr>\n<tr>\n<td>Isolation pri\/sec<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">16kV<\/td>\n<\/tr>\n<tr>\n<td>Surge suppressor<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">20kA\/40kA x 3 poles<\/td>\n<\/tr>\n<tr>\n<td>Signals and monitoring<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">Output Digital V-meter \/ A-meter<\/p>\n<p>Output line ON light<\/td>\n<\/tr>\n<tr>\n<td>Auxiliary outlet<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">1 x 10 A Schuko outlet with 10 A protection fuse<\/td>\n<\/tr>\n<tr>\n<td>Isolation monitoring<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">RI-R22 adjustable isolation tester on board<\/td>\n<\/tr>\n<tr>\n<td>Cooling<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">AF controlled by thermal contact<\/td>\n<\/tr>\n<tr>\n<td>Protection<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">IP20<\/td>\n<\/tr>\n<tr>\n<td>Weight kg<\/td>\n<td style=\"text-align: center;\">25<\/td>\n<td style=\"text-align: center;\">35<\/td>\n<td style=\"text-align: center;\">60<\/td>\n<td style=\"text-align: center;\">80<\/td>\n<\/tr>\n<tr>\n<td>Dimensions mm<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">19\u201d rack x 5U x depth 460mm<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">Operating conditions<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">Ambient temperature: 5 \u00f7 25 \u00b0c<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\">Ambient humidity percentage: 30 \u00f7 75% RH<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\">Altitude: 0 \u00f7 1000m above sea level<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Conditions of storage and transport.<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">Ambient temperature: -40 \u00f7 70 \u00b0 C<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"4\">Ambient humidity percentage: 10 \u00f7 100% RH<\/td>\n<\/tr>\n<tr>\n<td>Standards<\/td>\n<td style=\"text-align: center;\" colspan=\"4\">CEI EN 61558-2-4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Single and Three Phase high isolation protection system HI-SOL Series Single and three-phase rack wih 16kV isolation transformer 20\/40kA type 1-2 surge suppression Mcb input output protection Isolation resitance protection High-low voltage \u2013 high current protection IN A VERY TINY SPACE,\u00a0YOUR BROADCAST, PROTECTED SINGLE PHASE MODELS Model HI-SOL02M HI-SOL03M HI-SOL05M HI-SOL06M HI-SOL08M HI-SOL10M Type Class [&hellip;]<\/p>\n","protected":false},"featured_media":14518,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[226,224,229],"product_tag":[590,595,598,325],"class_list":["post-14522","product","type-product","status-publish","has-post-thumbnail","product_cat-single-phase-isolation-and-safety-transformers","product_cat-single-phase-transformers","product_cat-three-phase-isolation-transformers","product_tag-madical-use-isolation-transformer","product_tag-medical-use-transformer","product_tag-transformer-for-medical-environment","product_tag-transformers-for-medical-use","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","featured","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HI-SOL - Single and Three Phase 16kV high isolation protection system HI-SOL Series - K-factor<\/title>\n<meta name=\"description\" content=\"Isolation transformers for medical equipment power supply, single-phase, according to EN 60601-1 standards. Protection and isolation for medical environments.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HI-SOL - Single and Three Phase 16kV high isolation protection system HI-SOL Series - K-factor\" \/>\n<meta property=\"og:description\" content=\"Isolation transformers for medical equipment power supply, single-phase, according to EN 60601-1 standards. Protection and isolation for medical environments.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-21T13:12:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/04\/ft1280-hisol10t_01.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/trasformatori-elettrici\\\/trasformatori-monofase\\\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/trasformatori-elettrici\\\/trasformatori-monofase\\\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\\\/\",\"name\":\"HI-SOL - Single and Three Phase 16kV high isolation protection system HI-SOL Series - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/trasformatori-elettrici\\\/trasformatori-monofase\\\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/trasformatori-elettrici\\\/trasformatori-monofase\\\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/ft1280-hisol10t_01.jpg\",\"datePublished\":\"2025-04-29T17:08:05+00:00\",\"dateModified\":\"2026-05-21T13:12:05+00:00\",\"description\":\"Isolation transformers for medical equipment power supply, single-phase, according to EN 60601-1 standards. Protection and isolation for medical environments.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/trasformatori-elettrici\\\/trasformatori-monofase\\\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/trasformatori-elettrici\\\/trasformatori-monofase\\\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/trasformatori-elettrici\\\/trasformatori-monofase\\\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/ft1280-hisol10t_01.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/ft1280-hisol10t_01.jpg\",\"width\":1280,\"height\":720,\"caption\":\"single and three phase high isolation protection rack system\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/shop\\\/trasformatori-elettrici\\\/trasformatori-monofase\\\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HI-SOL &#8211; Single and Three Phase 16kV high isolation protection system HI-SOL Series\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"ELECTRONICS MADE EASY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HI-SOL - Single and Three Phase 16kV high isolation protection system HI-SOL Series - K-factor","description":"Isolation transformers for medical equipment power supply, single-phase, according to EN 60601-1 standards. Protection and isolation for medical environments.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/","og_locale":"en_US","og_type":"article","og_title":"HI-SOL - Single and Three Phase 16kV high isolation protection system HI-SOL Series - K-factor","og_description":"Isolation transformers for medical equipment power supply, single-phase, according to EN 60601-1 standards. Protection and isolation for medical environments.","og_url":"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/","og_site_name":"K-factor","article_modified_time":"2026-05-21T13:12:05+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/04\/ft1280-hisol10t_01.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/","url":"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/","name":"HI-SOL - Single and Three Phase 16kV high isolation protection system HI-SOL Series - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/04\/ft1280-hisol10t_01.jpg","datePublished":"2025-04-29T17:08:05+00:00","dateModified":"2026-05-21T13:12:05+00:00","description":"Isolation transformers for medical equipment power supply, single-phase, according to EN 60601-1 standards. Protection and isolation for medical environments.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/04\/ft1280-hisol10t_01.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2025\/04\/ft1280-hisol10t_01.jpg","width":1280,"height":720,"caption":"single and three phase high isolation protection rack system"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/shop\/trasformatori-elettrici\/trasformatori-monofase\/hi-sol-single-and-three-phase-high-isolation-transformers-for-broadcasting\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"PRODUCTS","item":"https:\/\/www.kfactor.it\/en\/shop\/"},{"@type":"ListItem","position":2,"name":"HI-SOL &#8211; Single and Three Phase 16kV high isolation protection system HI-SOL Series"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"ELECTRONICS MADE EASY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product\/14522","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media\/14518"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media?parent=14522"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_brand?post=14522"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_cat?post=14522"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_tag?post=14522"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}