{"id":6621,"date":"2024-01-17T01:02:30","date_gmt":"2024-01-17T00:02:30","guid":{"rendered":"https:\/\/www.kfactor.it\/kfactor\/en\/?post_type=product&#038;p=6621"},"modified":"2026-03-23T17:07:13","modified_gmt":"2026-03-23T16:07:13","slug":"tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/","title":{"rendered":"TTI64 -THREE PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE from 1 to 10kVA"},"content":{"rendered":"<p><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ttifv-piastra.jpg\"><br \/>\n<\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-ttifv-piastra.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3718 size-medium\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/ft-tti64-01-300x270.jpg\" alt=\"three phase isolation transformer\" width=\"300\" height=\"270\" \/><\/a><\/p>\n<p>THREE-PHASE, (NATURAL OR FORCED) AIR-COOLED ISOLATION TRANSFORMERS, INTENDED TO POWER GROUP II MEDICAL LOCATIONS, DESIGNED TO BE PERMANENTLY CONNECTED TO THE FIXED WIRING AND INTENDED TO EASTABLISH AN IT SYSTEM ON THE SECONDARY SIDE<\/p>\n<table style=\"height: 200px; background-color: #ffffff;\" width=\"700\">\n<tbody>\n<tr>\n<td>Ratings: from 1kVA to 10kVA<br \/>\nRated voltage\u00a0400V+N<br \/>\nFrequency 50\/60Hz<br \/>\nOpen type contruction<br \/>\nProtection\u00a0IP00<br \/>\nIsolation class\u00a0H (Ta max 45\u00b0C)<br \/>\nSeparated copper windings\u00a0cl. H<br \/>\nResin inpregnated and tropicalized<br \/>\nDouble copper earthed screen between primary and secondary<br \/>\nConnections by DIN rail terminal blocks<br \/>\nImpedance voltage\u00a0&lt; 3%<br \/>\nInrush current\u00a0&lt; 12 In<br \/>\nVector group: YNyn0<br \/>\nApplied standards: EN61558-2-15<\/td>\n<td style=\"width: 70px;\"><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2484\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi.jpg\" alt=\"schema trasformatore isolamento sicurezza schermo\" width=\"100\" height=\"75\" srcset=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi.jpg 800w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi-640x480.jpg 640w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi-350x263.jpg 350w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi-400x300.jpg 400w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi-768x576.jpg 768w\" sizes=\"auto, (max-width: 100px) 100vw, 100px\" \/><\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi.jpg\"><br \/>\n<\/a><\/td>\n<td style=\"width: 50px;\"><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafosep.gif\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2425\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafoiso.gif\" alt=\"simbolo trasformatore isolamento\" width=\"40\" height=\"60\" \/><\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafomed.gif\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2426\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafomed.gif\" alt=\"sim-trafomed\" width=\"53\" height=\"60\" \/><\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafoiso.gif\"><br \/>\n<\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/07\/sim-ce.gif\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-2352 aligncenter\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/07\/sim-ce.gif\" alt=\"sim-ce\" width=\"57\" height=\"43\" \/><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"height: 28px; background-color: #ffffff;\" width=\"700\">\n<tbody>\n<tr>\n<td colspan=\"2\">\u00a0<a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpm-01.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3516\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpm-01.jpg\" alt=\"di-ttpm-01\" width=\"320\" height=\"240\" srcset=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpm-01.jpg 320w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpm-01-1280x960.jpg 1280w\" sizes=\"auto, (max-width: 320px) 100vw, 320px\" \/><\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpm-01.jpg\"><br \/>\n<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"1\" width=\"700\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"64\">power<\/td>\n<td rowspan=\"2\" align=\"center\" bgcolor=\"#A7A7A7\" width=\"55\">part no.<\/td>\n<td colspan=\"2\" align=\"center\" bgcolor=\"#A7A7A7\" width=\"93\">losses (W)<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"68\">Imp. V<\/td>\n<td colspan=\"6\" align=\"center\" bgcolor=\"#A7A7A7\" width=\"159\">dimensions mm.<\/td>\n<td rowspan=\"2\" align=\"center\" bgcolor=\"#A7A7A7\" width=\"23\">DWG<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"40\">weight<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"64\">KVA<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"58\">no load<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"33\">load<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"68\">%<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"27\">A<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"27\">B<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"26\">C<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"26\">D<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"26\">E<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"17\">F<\/td>\n<td align=\"center\" bgcolor=\"#A7A7A7\" width=\"40\">kg.<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" width=\"64\">1<\/td>\n<td align=\"center\" width=\"55\">TTI6401<\/td>\n<td align=\"center\" width=\"58\">15<\/td>\n<td align=\"center\" width=\"33\">55<\/td>\n<td align=\"center\" width=\"68\">3.0<\/td>\n<td align=\"center\" width=\"27\">240<\/td>\n<td align=\"center\" width=\"27\">150<\/td>\n<td align=\"center\" width=\"26\">185<\/td>\n<td align=\"center\" width=\"26\">175<\/td>\n<td align=\"center\" width=\"26\">85<\/td>\n<td align=\"center\" width=\"17\">6<\/td>\n<td align=\"center\" width=\"23\">A<\/td>\n<td align=\"center\" width=\"40\">15.5<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" width=\"64\">2<\/td>\n<td align=\"center\" width=\"55\">TTI6402<\/td>\n<td align=\"center\" width=\"58\">28<\/td>\n<td align=\"center\" width=\"33\">90<\/td>\n<td align=\"center\" width=\"68\">3.0<\/td>\n<td align=\"center\" width=\"27\">240<\/td>\n<td align=\"center\" width=\"27\">175<\/td>\n<td align=\"center\" width=\"26\">185<\/td>\n<td align=\"center\" width=\"26\">175<\/td>\n<td align=\"center\" width=\"26\">110<\/td>\n<td align=\"center\" width=\"17\">6<\/td>\n<td align=\"center\" width=\"23\">A<\/td>\n<td align=\"center\" width=\"40\">23.0<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" width=\"64\">3<\/td>\n<td align=\"center\" width=\"55\">TTI6403<\/td>\n<td align=\"center\" width=\"58\">42<\/td>\n<td align=\"center\" width=\"33\">120<\/td>\n<td align=\"center\" width=\"68\">3.0<\/td>\n<td align=\"center\" width=\"27\">300<\/td>\n<td align=\"center\" width=\"27\">180<\/td>\n<td align=\"center\" width=\"26\">230<\/td>\n<td align=\"center\" width=\"26\">220<\/td>\n<td align=\"center\" width=\"26\">100<\/td>\n<td align=\"center\" width=\"17\">6<\/td>\n<td align=\"center\" width=\"23\">A<\/td>\n<td align=\"center\" width=\"40\">29.5<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" width=\"64\">4<\/td>\n<td align=\"center\" width=\"55\">TTI6404<\/td>\n<td align=\"center\" width=\"58\">60<\/td>\n<td align=\"center\" width=\"33\">160<\/td>\n<td align=\"center\" width=\"68\">3.0<\/td>\n<td align=\"center\" width=\"27\">300<\/td>\n<td align=\"center\" width=\"27\">190<\/td>\n<td align=\"center\" width=\"26\">230<\/td>\n<td align=\"center\" width=\"26\">220<\/td>\n<td align=\"center\" width=\"26\">110<\/td>\n<td align=\"center\" width=\"17\">6<\/td>\n<td align=\"center\" width=\"23\">A<\/td>\n<td align=\"center\" width=\"40\">34.0<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" width=\"64\">5<\/td>\n<td align=\"center\" width=\"55\">TTI6405<\/td>\n<td align=\"center\" width=\"58\">70<\/td>\n<td align=\"center\" width=\"33\">200<\/td>\n<td align=\"center\" width=\"68\">3.0<\/td>\n<td align=\"center\" width=\"27\">360<\/td>\n<td align=\"center\" width=\"27\">210<\/td>\n<td align=\"center\" width=\"26\">275<\/td>\n<td align=\"center\" width=\"26\">280<\/td>\n<td align=\"center\" width=\"26\">130<\/td>\n<td align=\"center\" width=\"17\">8<\/td>\n<td align=\"center\" width=\"23\">A<\/td>\n<td align=\"center\" width=\"40\">44.0<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" width=\"64\">6<\/td>\n<td align=\"center\" width=\"55\">TTI6406<\/td>\n<td align=\"center\" width=\"58\">70<\/td>\n<td align=\"center\" width=\"33\">220<\/td>\n<td align=\"center\" width=\"68\">3.0<\/td>\n<td align=\"center\" width=\"27\">360<\/td>\n<td align=\"center\" width=\"27\">210<\/td>\n<td align=\"center\" width=\"26\">275<\/td>\n<td align=\"center\" width=\"26\">280<\/td>\n<td align=\"center\" width=\"26\">130<\/td>\n<td align=\"center\" width=\"17\">8<\/td>\n<td align=\"center\" width=\"23\">A<\/td>\n<td align=\"center\" width=\"40\">47.5<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" width=\"64\">8<\/td>\n<td align=\"center\" width=\"55\">TTI6408<\/td>\n<td align=\"center\" width=\"58\">90<\/td>\n<td align=\"center\" width=\"33\">260<\/td>\n<td align=\"center\" width=\"68\">3.0<\/td>\n<td align=\"center\" width=\"27\">360<\/td>\n<td align=\"center\" width=\"27\">230<\/td>\n<td align=\"center\" width=\"26\">275<\/td>\n<td align=\"center\" width=\"26\">280<\/td>\n<td align=\"center\" width=\"26\">150<\/td>\n<td align=\"center\" width=\"17\">8<\/td>\n<td align=\"center\" width=\"23\">A<\/td>\n<td align=\"center\" width=\"40\">63.0<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" width=\"64\">10<\/td>\n<td align=\"center\" width=\"55\">TTI6410<\/td>\n<td align=\"center\" width=\"58\">90<\/td>\n<td align=\"center\" width=\"33\">280<\/td>\n<td align=\"center\" width=\"68\">3.0<\/td>\n<td align=\"center\" width=\"27\">360<\/td>\n<td align=\"center\" width=\"27\">230<\/td>\n<td align=\"center\" width=\"26\">275<\/td>\n<td align=\"center\" width=\"26\">280<\/td>\n<td align=\"center\" width=\"26\">150<\/td>\n<td align=\"center\" width=\"17\">8<\/td>\n<td align=\"center\" width=\"23\">A<\/td>\n<td align=\"center\" width=\"40\">66.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>THREE-PHASE, (NATURAL OR FORCED) AIR-COOLED ISOLATION TRANSFORMERS, INTENDED TO POWER GROUP II MEDICAL LOCATIONS, DESIGNED TO BE PERMANENTLY CONNECTED TO THE FIXED WIRING AND INTENDED TO EASTABLISH AN IT SYSTEM ON THE SECONDARY SIDE Ratings: from 1kVA to 10kVA Rated voltage\u00a0400V+N Frequency 50\/60Hz Open type contruction Protection\u00a0IP00 Isolation class\u00a0H (Ta max 45\u00b0C) Separated copper windings\u00a0cl. [&hellip;]<\/p>\n","protected":false},"featured_media":12981,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[229,227],"product_tag":[283,309,285,241,334,1688,327,307,308],"class_list":["post-6621","product","type-product","status-publish","has-post-thumbnail","product_cat-three-phase-isolation-transformers","product_cat-three-phase-transformers","product_tag-isolation","product_tag-isolation-transformer-2","product_tag-medical","product_tag-medical-environment","product_tag-medical-ups","product_tag-safety-transformers-3","product_tag-three-phase","product_tag-transformer","product_tag-transformer-2","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","featured","taxable","shipping-taxable","product-type-variable"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TTI64 -THREE PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE from 1 to 10kVA - K-factor<\/title>\n<meta name=\"description\" content=\"TTI64 three-phase isolation transformers (1-10kVA) for medical use. Featuring double copper shield and Vcc &lt; 3%, designed for IT systems per EN61558-2-15.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TTI64 -THREE PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE from 1 to 10kVA - K-factor\" \/>\n<meta property=\"og:description\" content=\"TTI64 three-phase isolation transformers (1-10kVA) for medical use. Featuring double copper shield and Vcc &lt; 3%, designed for IT systems per EN61558-2-15.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-23T16:07:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tti64-01.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/three-phase-transformers\\\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/three-phase-transformers\\\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\\\/\",\"name\":\"TTI64 -THREE PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE from 1 to 10kVA - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/three-phase-transformers\\\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/three-phase-transformers\\\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-tti64-01.jpg\",\"datePublished\":\"2024-01-17T00:02:30+00:00\",\"dateModified\":\"2026-03-23T16:07:13+00:00\",\"description\":\"TTI64 three-phase isolation transformers (1-10kVA) for medical use. Featuring double copper shield and Vcc &lt; 3%, designed for IT systems per EN61558-2-15.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/three-phase-transformers\\\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/three-phase-transformers\\\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/three-phase-transformers\\\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-tti64-01.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-tti64-01.jpg\",\"width\":1280,\"height\":720,\"caption\":\"trasformatore trifase isolamento uso medico\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/three-phase-transformers\\\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"TTI64 -THREE PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE from 1 to 10kVA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"ELECTRONICS MADE EASY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TTI64 -THREE PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE from 1 to 10kVA - K-factor","description":"TTI64 three-phase isolation transformers (1-10kVA) for medical use. Featuring double copper shield and Vcc &lt; 3%, designed for IT systems per EN61558-2-15.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/","og_locale":"en_US","og_type":"article","og_title":"TTI64 -THREE PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE from 1 to 10kVA - K-factor","og_description":"TTI64 three-phase isolation transformers (1-10kVA) for medical use. Featuring double copper shield and Vcc &lt; 3%, designed for IT systems per EN61558-2-15.","og_url":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/","og_site_name":"K-factor","article_modified_time":"2026-03-23T16:07:13+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tti64-01.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/","url":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/","name":"TTI64 -THREE PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE from 1 to 10kVA - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tti64-01.jpg","datePublished":"2024-01-17T00:02:30+00:00","dateModified":"2026-03-23T16:07:13+00:00","description":"TTI64 three-phase isolation transformers (1-10kVA) for medical use. Featuring double copper shield and Vcc &lt; 3%, designed for IT systems per EN61558-2-15.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tti64-01.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tti64-01.jpg","width":1280,"height":720,"caption":"trasformatore trifase isolamento uso medico"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/three-phase-transformers\/tti64-three-phase-isolation-transformers-for-medical-use-from-1-to-10kva\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"PRODUCTS","item":"https:\/\/www.kfactor.it\/en\/shop\/"},{"@type":"ListItem","position":2,"name":"TTI64 -THREE PHASE ISOLATION TRANSFORMERS FOR MEDICAL USE from 1 to 10kVA"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"ELECTRONICS MADE EASY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product\/6621","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media\/12981"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media?parent=6621"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_brand?post=6621"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_cat?post=6621"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_tag?post=6621"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}