{"id":6802,"date":"2024-01-12T00:06:49","date_gmt":"2024-01-11T23:06:49","guid":{"rendered":"https:\/\/www.kfactor.it\/kfactor\/en\/?post_type=product&#038;p=6802"},"modified":"2026-03-23T16:37:14","modified_gmt":"2026-03-23T15:37:14","slug":"tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/","title":{"rendered":"TMIFV &#8211; SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA &#8211; for isolation of photovoltaic plants"},"content":{"rendered":"<h3>SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA &#8211; for isolation of photovoltaic plants<\/h3>\n<table style=\"height: 200px; background-color: #ffffff;\" width=\"700\">\n<tbody>\n<tr>\n<td>Input\/output rated voltage\u00a0230Vac<br \/>\nFrequency 50\/60Hz<br \/>\nOpen type construction<br \/>\nIP00 protection degree<br \/>\nIsolation class\u00a0F (Ta max 35\u00b0C)<br \/>\nSeparated copper windings\u00a0cl. H 200\u00b0C<br \/>\nMax inrush current\u00a012In<br \/>\nImp. V\u00a0% &lt; 5%<br \/>\nResin impregnated and tropicalized<br \/>\nCopper earthed screen between primary and secondary<br \/>\nConnections on terminals for\u00a0DIN rail<br \/>\nLow losses magnetic core<br \/>\nInstallation in metal enclosure available on request<br \/>\nApplied standards\u00a0: EN61558-2-4<br \/>\nOptional: lifting lugs<br \/>\nTHREE PHASE VERSION AVAILABLE <a href=\"https:\/\/www.kfactor.it\/en\/shop\/tti-fv-three-phase-isolation-transformers-designed-for-photovoltaic-plants-from-10-to-500kva\/\">HERE<\/a><\/td>\n<td>\n<pre><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2484\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi.jpg\" alt=\"schema trasformatore isolamento sicurezza schermo\" width=\"100\" height=\"75\" srcset=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi.jpg 800w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi-640x480.jpg 640w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi-350x263.jpg 350w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi-400x300.jpg 400w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi-768x576.jpg 768w\" sizes=\"auto, (max-width: 100px) 100vw, 100px\" \/><\/a>\r\n<\/pre>\n<\/td>\n<td>\n<pre><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafoiso.gif\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2425 size-full\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafoiso.gif\" alt=\"simbolo trasformatore isolamento\" width=\"40\" height=\"60\" \/><\/a>\r\n <a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/07\/sim-ce.gif\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-2352 aligncenter\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/07\/sim-ce.gif\" alt=\"sim-ce\" width=\"57\" height=\"43\" \/><\/a><\/pre>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"height: 200px;\" width=\"700px\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\" colspan=\"12\">FVJ VERSION<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"text-align: center; height: 1px;\" rowspan=\"2\">power<br \/>\nVA<\/td>\n<td style=\"text-align: center; height: 1px;\" rowspan=\"2\">part no.<\/td>\n<td style=\"text-align: center; height: 56px;\" colspan=\"3\">losses<br \/>\nW<\/td>\n<td style=\"text-align: center; height: 1px;\" rowspan=\"2\">eff<br \/>\n%<\/td>\n<td style=\"text-align: center; height: 56px;\" colspan=\"3\">dimensions mm.<\/td>\n<td style=\"text-align: center; height: 1px;\" rowspan=\"2\">DWG<\/td>\n<td style=\"text-align: center; height: 1px;\" rowspan=\"2\">weight<br \/>\nkg<\/td>\n<td style=\"text-align: center; height: 1px;\" rowspan=\"2\">box<\/td>\n<\/tr>\n<tr style=\"height: 56px;\">\n<td style=\"text-align: center; height: 56px;\">no load<\/td>\n<td style=\"text-align: center; height: 56px;\">load<\/td>\n<td style=\"text-align: center; height: 56px;\">total<\/td>\n<td style=\"text-align: center; height: 56px;\">a<\/td>\n<td style=\"text-align: center; height: 56px;\">b<\/td>\n<td style=\"text-align: center; height: 56px;\">c<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">3<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI249FVJ<\/td>\n<td style=\"text-align: center; height: 24px;\">42<\/td>\n<td style=\"text-align: center; height: 24px;\">96<\/td>\n<td style=\"text-align: center; height: 24px;\">138<\/td>\n<td style=\"text-align: center; height: 24px;\">95.42<\/td>\n<td style=\"text-align: center; height: 24px;\">200<\/td>\n<td style=\"text-align: center; height: 24px;\">270<\/td>\n<td style=\"text-align: center; height: 24px;\">255<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">27<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM02<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">4<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI267FVJ<\/td>\n<td style=\"text-align: center; height: 24px;\">52<\/td>\n<td style=\"text-align: center; height: 24px;\">121<\/td>\n<td style=\"text-align: center; height: 24px;\">173<\/td>\n<td style=\"text-align: center; height: 24px;\">95.67<\/td>\n<td style=\"text-align: center; height: 24px;\">240<\/td>\n<td style=\"text-align: center; height: 24px;\">280<\/td>\n<td style=\"text-align: center; height: 24px;\">305<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">34<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">5<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI287FVJ<\/td>\n<td style=\"text-align: center; height: 24px;\">60<\/td>\n<td style=\"text-align: center; height: 24px;\">149<\/td>\n<td style=\"text-align: center; height: 24px;\">209<\/td>\n<td style=\"text-align: center; height: 24px;\">95.81<\/td>\n<td style=\"text-align: center; height: 24px;\">240<\/td>\n<td style=\"text-align: center; height: 24px;\">290<\/td>\n<td style=\"text-align: center; height: 24px;\">305<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">39<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">6<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI307FVJ<\/td>\n<td style=\"text-align: center; height: 24px;\">70<\/td>\n<td style=\"text-align: center; height: 24px;\">180<\/td>\n<td style=\"text-align: center; height: 24px;\">250<\/td>\n<td style=\"text-align: center; height: 24px;\">95.83<\/td>\n<td style=\"text-align: center; height: 24px;\">280<\/td>\n<td style=\"text-align: center; height: 24px;\">300<\/td>\n<td style=\"text-align: center; height: 24px;\">355<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">46<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">8<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI347FVJ<\/td>\n<td style=\"text-align: center; height: 24px;\">82<\/td>\n<td style=\"text-align: center; height: 24px;\">194<\/td>\n<td style=\"text-align: center; height: 24px;\">276<\/td>\n<td style=\"text-align: center; height: 24px;\">96.55<\/td>\n<td style=\"text-align: center; height: 24px;\">280<\/td>\n<td style=\"text-align: center; height: 24px;\">310<\/td>\n<td style=\"text-align: center; height: 24px;\">355<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">58<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">10<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI387FVJ<\/td>\n<td style=\"text-align: center; height: 24px;\">124<\/td>\n<td style=\"text-align: center; height: 24px;\">179<\/td>\n<td style=\"text-align: center; height: 24px;\">303<\/td>\n<td style=\"text-align: center; height: 24px;\">96.97<\/td>\n<td style=\"text-align: center; height: 24px;\">280<\/td>\n<td style=\"text-align: center; height: 24px;\">350<\/td>\n<td style=\"text-align: center; height: 24px;\">355<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">78<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"height: 200px;\" width=\"700px\">\n<tbody>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\" colspan=\"12\">VERSIONE FVK &#8211; ALTO RENDIMENTO-PERDITE BASSISSIME<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 48px;\" rowspan=\"2\">power<br \/>\nVA<\/td>\n<td style=\"text-align: center; height: 48px;\" rowspan=\"2\">part no.<\/td>\n<td style=\"text-align: center; height: 24px;\" colspan=\"3\">losses<br \/>\nW<\/td>\n<td style=\"text-align: center; height: 48px;\" rowspan=\"2\">eff<br \/>\n%<\/td>\n<td style=\"text-align: center; height: 24px;\" colspan=\"3\">dimensions mm.<\/td>\n<td style=\"text-align: center; height: 48px;\" rowspan=\"2\">DWG<\/td>\n<td style=\"text-align: center; height: 48px;\" rowspan=\"2\">weight<br \/>\nkg<\/td>\n<td style=\"text-align: center; height: 48px;\" rowspan=\"2\">box<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">no load<\/td>\n<td style=\"text-align: center; height: 24px;\">load<\/td>\n<td style=\"text-align: center; height: 24px;\">total<\/td>\n<td style=\"text-align: center; height: 24px;\">a<\/td>\n<td style=\"text-align: center; height: 24px;\">b<\/td>\n<td style=\"text-align: center; height: 24px;\">c<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">3<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI249FVK<\/td>\n<td style=\"text-align: center; height: 24px;\">21<\/td>\n<td style=\"text-align: center; height: 24px;\">81<\/td>\n<td style=\"text-align: center; height: 24px;\">102<\/td>\n<td style=\"text-align: center; height: 24px;\">96.58<\/td>\n<td style=\"text-align: center; height: 24px;\">200<\/td>\n<td style=\"text-align: center; height: 24px;\">260<\/td>\n<td style=\"text-align: center; height: 24px;\">255<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">24<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM02<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">4<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI267FVK<\/td>\n<td style=\"text-align: center; height: 24px;\">26<\/td>\n<td style=\"text-align: center; height: 24px;\">110<\/td>\n<td style=\"text-align: center; height: 24px;\">136<\/td>\n<td style=\"text-align: center; height: 24px;\">96.61<\/td>\n<td style=\"text-align: center; height: 24px;\">240<\/td>\n<td style=\"text-align: center; height: 24px;\">270<\/td>\n<td style=\"text-align: center; height: 24px;\">305<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">31<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">5<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI287FVK<\/td>\n<td style=\"text-align: center; height: 24px;\">30<\/td>\n<td style=\"text-align: center; height: 24px;\">130<\/td>\n<td style=\"text-align: center; height: 24px;\">161<\/td>\n<td style=\"text-align: center; height: 24px;\">96.77<\/td>\n<td style=\"text-align: center; height: 24px;\">240<\/td>\n<td style=\"text-align: center; height: 24px;\">280<\/td>\n<td style=\"text-align: center; height: 24px;\">305<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">35<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">6<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI307FVK<\/td>\n<td style=\"text-align: center; height: 24px;\">35<\/td>\n<td style=\"text-align: center; height: 24px;\">135<\/td>\n<td style=\"text-align: center; height: 24px;\">170<\/td>\n<td style=\"text-align: center; height: 24px;\">97.17<\/td>\n<td style=\"text-align: center; height: 24px;\">240<\/td>\n<td style=\"text-align: center; height: 24px;\">290<\/td>\n<td style=\"text-align: center; height: 24px;\">305<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">42<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">8<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI347FVK<\/td>\n<td style=\"text-align: center; height: 24px;\">42<\/td>\n<td style=\"text-align: center; height: 24px;\">195<\/td>\n<td style=\"text-align: center; height: 24px;\">237<\/td>\n<td style=\"text-align: center; height: 24px;\">97.04<\/td>\n<td style=\"text-align: center; height: 24px;\">280<\/td>\n<td style=\"text-align: center; height: 24px;\">300<\/td>\n<td style=\"text-align: center; height: 24px;\">355<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">50<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"text-align: center; height: 24px;\">10<\/td>\n<td style=\"text-align: center; height: 24px;\">TMI387FVK<\/td>\n<td style=\"text-align: center; height: 24px;\">53<\/td>\n<td style=\"text-align: center; height: 24px;\">202<\/td>\n<td style=\"text-align: center; height: 24px;\">255<\/td>\n<td style=\"text-align: center; height: 24px;\">97.44<\/td>\n<td style=\"text-align: center; height: 24px;\">280<\/td>\n<td style=\"text-align: center; height: 24px;\">320<\/td>\n<td style=\"text-align: center; height: 24px;\">355<\/td>\n<td style=\"text-align: center; height: 24px;\">A<\/td>\n<td style=\"text-align: center; height: 24px;\">62<\/td>\n<td style=\"text-align: center; height: 24px;\">SAM03<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"height: 28px; background-color: #ffffff;\" width=\"700\">\n<tbody>\n<tr>\n<td><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/di-mc.gif\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2487 size-medium\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/di-mc-300x225.gif\" alt=\"disegno trasformatori monofase isolamento per fotovoltaico morsettiere\" width=\"300\" height=\"225\" \/><\/a><\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2486 size-medium\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/di-mcpiastra-300x225.gif\" alt=\"disegno trasformatore monofase fotovoltaico bulloni\" width=\"300\" height=\"225\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">B<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA &#8211; for isolation of photovoltaic plants Input\/output rated voltage\u00a0230Vac Frequency 50\/60Hz Open type construction IP00 protection degree Isolation class\u00a0F (Ta max 35\u00b0C) Separated copper windings\u00a0cl. H 200\u00b0C Max inrush current\u00a012In Imp. V\u00a0% &lt; 5% Resin impregnated and tropicalized Copper earthed screen between primary and secondary Connections on [&hellip;]<\/p>\n","protected":false},"featured_media":12899,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[226,224],"product_tag":[283,314,1688,287,318,308,319],"class_list":["post-6802","product","type-product","status-publish","has-post-thumbnail","product_cat-single-phase-isolation-and-safety-transformers","product_cat-single-phase-transformers","product_tag-isolation","product_tag-isolation-transformers-2","product_tag-safety-transformers-3","product_tag-single-phase","product_tag-single-phase-transformers-2","product_tag-transformer-2","product_tag-transformers-for-photovoltaic-plants","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","featured","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TMIFV - SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA - for isolation of photovoltaic plants - K-factor<\/title>\n<meta name=\"description\" content=\"TMIFV isolation transformers (3-10kVA) for photovoltaic systems. High efficiency, copper shield, and low losses, compliant with EN61558-2-4 standards.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TMIFV - SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA - for isolation of photovoltaic plants - K-factor\" \/>\n<meta property=\"og:description\" content=\"TMIFV isolation transformers (3-10kVA) for photovoltaic systems. High efficiency, copper shield, and low losses, compliant with EN61558-2-4 standards.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-23T15:37:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/single-phase-transformers\\\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/single-phase-transformers\\\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\\\/\",\"name\":\"TMIFV - SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA - for isolation of photovoltaic plants - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/single-phase-transformers\\\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/single-phase-transformers\\\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-tmi.jpg\",\"datePublished\":\"2024-01-11T23:06:49+00:00\",\"dateModified\":\"2026-03-23T15:37:14+00:00\",\"description\":\"TMIFV isolation transformers (3-10kVA) for photovoltaic systems. High efficiency, copper shield, and low losses, compliant with EN61558-2-4 standards.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/single-phase-transformers\\\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/single-phase-transformers\\\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/single-phase-transformers\\\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-tmi.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-tmi.jpg\",\"width\":1280,\"height\":720,\"caption\":\"trasformatore monofase isolamento\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/electrical-transformers\\\/single-phase-transformers\\\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"TMIFV &#8211; SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA &#8211; for isolation of photovoltaic plants\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"ELECTRONICS MADE EASY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TMIFV - SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA - for isolation of photovoltaic plants - K-factor","description":"TMIFV isolation transformers (3-10kVA) for photovoltaic systems. High efficiency, copper shield, and low losses, compliant with EN61558-2-4 standards.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/","og_locale":"en_US","og_type":"article","og_title":"TMIFV - SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA - for isolation of photovoltaic plants - K-factor","og_description":"TMIFV isolation transformers (3-10kVA) for photovoltaic systems. High efficiency, copper shield, and low losses, compliant with EN61558-2-4 standards.","og_url":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/","og_site_name":"K-factor","article_modified_time":"2026-03-23T15:37:14+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/","url":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/","name":"TMIFV - SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA - for isolation of photovoltaic plants - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg","datePublished":"2024-01-11T23:06:49+00:00","dateModified":"2026-03-23T15:37:14+00:00","description":"TMIFV isolation transformers (3-10kVA) for photovoltaic systems. High efficiency, copper shield, and low losses, compliant with EN61558-2-4 standards.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg","width":1280,"height":720,"caption":"trasformatore monofase isolamento"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/en\/shop\/electrical-transformers\/single-phase-transformers\/tmifv-trasformatori-monofase-isolamento-impianti-fotovoltaici-3-10kva\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"PRODUCTS","item":"https:\/\/www.kfactor.it\/en\/shop\/"},{"@type":"ListItem","position":2,"name":"TMIFV &#8211; SINGLE PHASE ISOLATION TRANSFORMERS from 3 to 10kVA &#8211; for isolation of photovoltaic plants"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"ELECTRONICS MADE EASY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product\/6802","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media\/12899"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media?parent=6802"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_brand?post=6802"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_cat?post=6802"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_tag?post=6802"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}