{"id":7171,"date":"2024-03-16T01:52:52","date_gmt":"2024-03-16T00:52:52","guid":{"rendered":"https:\/\/www.kfactor.it\/kfactor\/en\/?post_type=product&#038;p=7171"},"modified":"2026-08-05T17:00:09","modified_gmt":"2026-08-05T15:00:09","slug":"varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/","title":{"rendered":"VARxxF-3N &#8211; THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V"},"content":{"rendered":"<h3>THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V<\/h3>\n<p>K-FACTOR VARIABLE TRANSFORMER ARE MADE FOR ALL THE EXPERIMENTATION AND TESTING NEEDS OF TECHNICAL OFFICES, LABORATORIES AND INDUSTRIES. THEY ARE SUPPLIED TO HAVE A VARIABLE VOLTAGE FROM 0V TO 250Vac SINGLE-PHASE OR FROM 0V TO 435V THREE-PHASE WITH DIFFERENT RATED CURRENTS.<\/p>\n<p>These products are supplied freestanding, to be installed on the back of switchboard panels for models up to 20 A. For higher power models, assembly must be carried out horizontally.<\/p>\n<p>Knob and dial for adjustment are optional.<\/p>\n<table width=\"650\">\n<tbody>\n<tr>\n<td width=\"388\">Input voltage: 400Vac three phase<br \/>\nOutput adjustable voltage: 0 : 435Vac<br \/>\nOpen type, panel mounting<br \/>\nIP00 grade of protection<br \/>\nIsolation class\u00a0E (AT max 45\u00b0C)<br \/>\nSingle winding with input intermediate tap<br \/>\nResin impregnated and tropicalized<br \/>\nKnob and dial available on request<br \/>\nAvailable versions: with gear motor and microswitches, stabilized, closed type<br \/>\n<a href=\"\/?product_cat=varf-1n-variatori-tensione-monofase-manuali-giorno-4a-60a-0250v\">SINGLE PHASE MODEL AVAILABLE<\/a><\/td>\n<td width=\"256\">\u00a0<a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/sch-varf3-n.gif\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4738\" title=\"scheme of three phase variable transformer\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/sch-varf3-n.gif\" alt=\"scheme of three phase variable transformer\" width=\"168\" height=\"144\" \/><\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/sch-varf1-n.png\"><br \/>\n<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"650\">\n<tbody>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-12798\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/di-var20f-3n.jpg\" alt=\"variatore tensione trifase disegno\" width=\"173\" height=\"255\" \/><\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-12788\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n-400x225.jpg\" alt=\"variatore tensione trifase\" width=\"400\" height=\"225\" srcset=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n-400x225.jpg 400w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n-1024x576.jpg 1024w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n-768x432.jpg 768w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n-800x450.jpg 800w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n-768x432-480x270.jpg 480w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n.jpg 1280w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"650\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\">corrent<\/td>\n<td style=\"text-align: center;\" rowspan=\"2\">code<\/td>\n<td style=\"text-align: center;\">MAX<\/td>\n<td style=\"text-align: center;\" colspan=\"6\">dimensions mm.<\/td>\n<td style=\"text-align: center;\">weight<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">kVA<\/td>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">B<\/td>\n<td style=\"text-align: center;\">H<\/td>\n<td style=\"text-align: center;\">C<\/td>\n<td style=\"text-align: center;\">D<\/td>\n<td style=\"text-align: center;\">E<\/td>\n<td style=\"text-align: center;\">kg.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">4<\/td>\n<td style=\"text-align: center;\">VAR04F-3N<\/td>\n<td style=\"text-align: center;\">3.0<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">520<\/td>\n<td style=\"text-align: center;\">160<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">28<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">6<\/td>\n<td style=\"text-align: center;\">VAR06F-3N<\/td>\n<td style=\"text-align: center;\">4.5<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">520<\/td>\n<td style=\"text-align: center;\">165<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">37<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">8<\/td>\n<td style=\"text-align: center;\">VAR08F-3N<\/td>\n<td style=\"text-align: center;\">6.0<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">520<\/td>\n<td style=\"text-align: center;\">160<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">38<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">VAR10F-3N<\/td>\n<td style=\"text-align: center;\">7.5<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">520<\/td>\n<td style=\"text-align: center;\">160<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">46<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">14<\/td>\n<td style=\"text-align: center;\">VAR14F-3N<\/td>\n<td style=\"text-align: center;\">10.5<\/td>\n<td style=\"text-align: center;\">220<\/td>\n<td style=\"text-align: center;\">220<\/td>\n<td style=\"text-align: center;\">540<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">57<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">18<\/td>\n<td style=\"text-align: center;\">VAR18F-3N<\/td>\n<td style=\"text-align: center;\">13.5<\/td>\n<td style=\"text-align: center;\">220<\/td>\n<td style=\"text-align: center;\">220<\/td>\n<td style=\"text-align: center;\">590<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">67<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">20<\/td>\n<td style=\"text-align: center;\">VAR20F-3N<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">220<\/td>\n<td style=\"text-align: center;\">220<\/td>\n<td style=\"text-align: center;\">590<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">10<\/td>\n<td style=\"text-align: center;\">69<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"650\">\n<tbody>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-8618\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2020\/04\/dis-var-3n02.jpg\" alt=\"three phase variable transformer dimensional drawing\" width=\"200\" height=\"260\" \/><\/td>\n<td style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-12790\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var40f-3n-400x225.jpg\" alt=\" Per utilizzare questo trasformatore \u00b7 Colleghi l\u2019ingresso sull\u2019avvolgimento primario posto dal lato dello schermo (marcato SH o SCH) \u00b7 Il morsetto SH o SCH (schermo di isolamento tra primario e secondario) va messo a terra insieme al telaio metallico del trasformatore. \u00b7 Collegare il carico al morsetto marcato 0 \u2013 230V \u00b7 SECONDARIO FASE-NEUTRO: come ben sapr\u00e0 questo collegamento \u00e8 \u201cirrituale\u201d e non genera un neutro, ma collegando il morsetto \u201c0\u201d del secondario a terra, avendo un isolamento galvanico, avrete il morsetto \u201c0\u201d a 0V verso terra ed il morsetto 230V come \u201cfase\u201d. Le utenze che hanno bisogno di fase-neutro funzioneranno regolarmente. Si raccomanda di rivedere le protezioni perch\u00e9 in questo modo si perde la protezione usualmente data dal trasformatore di isolamento dai contatti accidentali, ma il differenziale a monte potrebbe risultare inidoneo, quindi dovr\u00e0 essere messa una protezione idonea a valle del trasformatore e un tester di isolamento a valle per proteggere l\u2019utente. Un professionista abilitato dovr\u00e0 certificare l\u2019impianto, K-factor non si assume alcune responsabilit\u00e0 sul corretto utilizzo e installazione delle protezioni per l\u2019utente.\" width=\"400\" height=\"225\" srcset=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var40f-3n-400x225.jpg 400w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var40f-3n-1024x576.jpg 1024w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var40f-3n-768x432.jpg 768w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var40f-3n-800x450.jpg 800w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var40f-3n-768x432-480x270.jpg 480w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var40f-3n.jpg 1280w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"650\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\">corrent<\/td>\n<td style=\"text-align: center;\">code<\/td>\n<td style=\"text-align: center;\">MAX<\/td>\n<td style=\"text-align: center;\" colspan=\"5\">dimensions mm.<\/td>\n<td style=\"text-align: center;\">weight<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\"><\/td>\n<td style=\"text-align: center;\">kVA<\/td>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">B<\/td>\n<td style=\"text-align: center;\">H<\/td>\n<td style=\"text-align: center;\">D<\/td>\n<td style=\"text-align: center;\">E<\/td>\n<td style=\"text-align: center;\">kg.<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">26<\/td>\n<td style=\"text-align: center;\">VAR26F-3N<\/td>\n<td style=\"text-align: center;\">19.5<\/td>\n<td style=\"text-align: center;\">420<\/td>\n<td style=\"text-align: center;\">420<\/td>\n<td style=\"text-align: center;\">820<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">150<\/td>\n<td style=\"text-align: center;\">119<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">30<\/td>\n<td style=\"text-align: center;\">VAR30F-3N<\/td>\n<td style=\"text-align: center;\">23.5<\/td>\n<td style=\"text-align: center;\">420<\/td>\n<td style=\"text-align: center;\">420<\/td>\n<td style=\"text-align: center;\">820<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">150<\/td>\n<td style=\"text-align: center;\">131<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">40<\/td>\n<td style=\"text-align: center;\">VAR40F-3N<\/td>\n<td style=\"text-align: center;\">30<\/td>\n<td style=\"text-align: center;\">420<\/td>\n<td style=\"text-align: center;\">420<\/td>\n<td style=\"text-align: center;\">820<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">150<\/td>\n<td style=\"text-align: center;\">155<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">50<\/td>\n<td style=\"text-align: center;\">VAR50F-3N<\/td>\n<td style=\"text-align: center;\">37.5<\/td>\n<td style=\"text-align: center;\">480<\/td>\n<td style=\"text-align: center;\">480<\/td>\n<td style=\"text-align: center;\">820<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">150<\/td>\n<td style=\"text-align: center;\">207<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">60<\/td>\n<td style=\"text-align: center;\">VAR60F-3N<\/td>\n<td style=\"text-align: center;\">45<\/td>\n<td style=\"text-align: center;\">480<\/td>\n<td style=\"text-align: center;\">480<\/td>\n<td style=\"text-align: center;\">880<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">150<\/td>\n<td style=\"text-align: center;\">228<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">80<\/td>\n<td style=\"text-align: center;\">VAR80F-3N<\/td>\n<td style=\"text-align: center;\">60<\/td>\n<td style=\"text-align: center;\">480<\/td>\n<td style=\"text-align: center;\">480<\/td>\n<td style=\"text-align: center;\">880<\/td>\n<td style=\"text-align: center;\">15<\/td>\n<td style=\"text-align: center;\">150<\/td>\n<td style=\"text-align: center;\">237<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V K-FACTOR VARIABLE TRANSFORMER ARE MADE FOR ALL THE EXPERIMENTATION AND TESTING NEEDS OF TECHNICAL OFFICES, LABORATORIES AND INDUSTRIES. THEY ARE SUPPLIED TO HAVE A VARIABLE VOLTAGE FROM 0V TO 250Vac SINGLE-PHASE OR FROM 0V TO 435V THREE-PHASE WITH DIFFERENT RATED CURRENTS. These products are [&hellip;]<\/p>\n","protected":false},"featured_media":12788,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[230],"product_tag":[341,344,340,337,347,346],"class_list":["post-7171","product","type-product","status-publish","has-post-thumbnail","product_cat-variable-transformers","product_tag-closed-type-variable-transformer-2","product_tag-linear-variator","product_tag-open-type-variable-transformer","product_tag-three-phase-variac","product_tag-three-phase-variators","product_tag-voltage-variators","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","featured","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>VARxxF-3N - THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V - K-factor<\/title>\n<meta name=\"description\" content=\"VARF-3N series manual three-phase voltage variators (4A-60A). Linear 0-435Vac regulation, open-type design for industrial mounting and test benches.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"VARxxF-3N - THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V - K-factor\" \/>\n<meta property=\"og:description\" content=\"VARF-3N series manual three-phase voltage variators (4A-60A). Linear 0-435Vac regulation, open-type design for industrial mounting and test benches.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-05T15:00:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/variable-transformers\\\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/variable-transformers\\\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\\\/\",\"name\":\"VARxxF-3N - THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/variable-transformers\\\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/variable-transformers\\\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-var10f-3n.jpg\",\"datePublished\":\"2024-03-16T00:52:52+00:00\",\"dateModified\":\"2026-08-05T15:00:09+00:00\",\"description\":\"VARF-3N series manual three-phase voltage variators (4A-60A). Linear 0-435Vac regulation, open-type design for industrial mounting and test benches.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/variable-transformers\\\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/variable-transformers\\\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/variable-transformers\\\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-var10f-3n.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-var10f-3n.jpg\",\"width\":1280,\"height\":720,\"caption\":\"variatore tensione trifase\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/variable-transformers\\\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"VARxxF-3N &#8211; THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"ELECTRONICS MADE EASY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"VARxxF-3N - THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V - K-factor","description":"VARF-3N series manual three-phase voltage variators (4A-60A). Linear 0-435Vac regulation, open-type design for industrial mounting and test benches.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/","og_locale":"en_US","og_type":"article","og_title":"VARxxF-3N - THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V - K-factor","og_description":"VARF-3N series manual three-phase voltage variators (4A-60A). Linear 0-435Vac regulation, open-type design for industrial mounting and test benches.","og_url":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/","og_site_name":"K-factor","article_modified_time":"2026-08-05T15:00:09+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/","url":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/","name":"VARxxF-3N - THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n.jpg","datePublished":"2024-03-16T00:52:52+00:00","dateModified":"2026-08-05T15:00:09+00:00","description":"VARF-3N series manual three-phase voltage variators (4A-60A). Linear 0-435Vac regulation, open-type design for industrial mounting and test benches.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-var10f-3n.jpg","width":1280,"height":720,"caption":"variatore tensione trifase"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/en\/shop\/variable-transformers\/varf-3n-three-phase-open-type-variable-transformers-from-4a-to-60a-0435v\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"PRODUCTS","item":"https:\/\/www.kfactor.it\/en\/shop\/"},{"@type":"ListItem","position":2,"name":"VARxxF-3N &#8211; THREE PHASE OPEN TYPE VARIABLE TRANSFORMERS from 4A to 80A 0:435V"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"ELECTRONICS MADE EASY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product\/7171","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media\/12788"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media?parent=7171"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_brand?post=7171"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_cat?post=7171"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_tag?post=7171"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}