{"id":8405,"date":"2024-02-19T00:27:25","date_gmt":"2024-02-18T23:27:25","guid":{"rendered":"https:\/\/www.kfactor.it\/kfactor\/?post_type=product&#038;p=8405"},"modified":"2026-05-21T13:05:54","modified_gmt":"2026-05-21T11:05:54","slug":"eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/","title":{"rendered":"EG133 &#8211; EF133 &#8211; THREE PHASE UPS, DOUBLE CONVERSION SINE WAVE, 10 TO 120KVA"},"content":{"rendered":"<p>EG133 is available in capacities from 10KVA to 120 KVA, with on-line double conversion by digital control; for its versatility it is suitable for powering any electrical and electronic system in critical situations; it is possible to use the product as a frequency converter 50 \/ 60Hz or with the use of motor current generators<br \/>\n\u2022 UPS DOUBLE CONVERSION<br \/>\nA real UPS DOUBLE CONVERSION which will provide a perfect power, for high quality complete protection of your sensitive devices, such as PC Networks (Network), Small computer centers, Server, Telecommunications, Sanitary appliances \/ hospital, and general industrial applications<br \/>\n\u2022 OUTPUT POWER FACTOR \u03c6 0.8<br \/>\nComparing this line UPS ON-LINE with the competition on the market today, we can say that they have the best UPS output power factor 0.8. They offer high performance and efficiency for critical applications<br \/>\n\u2022 WIDE INPUT RANGE (200 V -500 V)<br \/>\nEG133 is able to provide stable and clean power to the connected equipment even in very critical and unstable environments.<br \/>\n\u2022 FREQUENCY CONVERTER FUNCTION 50\/60 Hz<br \/>\nLock output frequency at 50Hz or 60Hz regardless of input frequency and eliminates the By-Pass<br \/>\n\u2022 (EPO) Emergency Power Off FUNCTION<br \/>\nThis function serves for a UPS shutdown by the personnel in case of fire and other emergency situation.<br \/>\n\u2022 OPERATION OF CONTEMPORARY SNMP + USB + RS-232<br \/>\nThis feature allows you to use communication to all USB ports, RS-232 and SNMP simultaneously.<br \/>\n\u2022 BATTERY CHARGER DESIGNED TO OPTIMIZE THE PERFORMANCE OF THE BATTERY<br \/>\n. The EG133 series is equipped by a battery charging 3 extendable step, to optimize battery performance. This feature prolongs the autonomy and optimizes battery recharge time also the extension of the battery charger is essential for recharging of batteries with higher power used to achieve longer ranges.<br \/>\n\u2022 BY-PASS FOR MAINTENANCE<br \/>\nThe By-Pass Manual ensures the lack of voltage inside the UPS for maintenance, ensuring supply to the equipment connected downstream.<br \/>\n\u2022 OPERATION PARALLEL redundant<br \/>\nThe EG133, can work in parallel redundant up to 3 units; This increases the power capacity and the safety of work without interruption of the service<br \/>\n\u2022 POWER FACTOR CORRECTION ON ALL STAGES<br \/>\nPFC improves the quality of the current consumption and increases the energy efficiency, with the consequent economic savings<br \/>\n\u2022 COMMUNICATION<br \/>\nSoftware for all operating systems and network environments. supervision and shutdown platform<br \/>\nGUARANTEE 24 MONTHS<\/p>\n<table width=\"700\">\n<tbody>\n<tr>\n<td colspan=\"7\" width=\"700\"><strong>EG133 10K\/40K three phase \/ three phase ONLINE UPS DOUBLE CONVERSION<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>MODEL<\/strong><\/td>\n<td width=\"118\"><strong>\u00a0EG13310K (S) <\/strong><\/td>\n<td width=\"113\"><strong>EG13320K (S)<\/strong><\/td>\n<td colspan=\"2\" width=\"113\"><strong>EG13330K (S)<\/strong><\/td>\n<td width=\"128\"><strong>EG13340K (S)<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>PHASE<\/strong><\/td>\n<td colspan=\"2\" width=\"231\"><strong>Three phase input \/ three phase \u2013 single phase output<\/strong><\/td>\n<td colspan=\"3\" width=\"242\"><strong>Three phase input \/ three phase output<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>POWER<\/strong><\/td>\n<td width=\"118\">10 KVA \/ 10 KW<\/td>\n<td width=\"113\">20 KVA \/ 20 KW<\/td>\n<td colspan=\"2\" width=\"113\">30 KVA \/ 30 KW<\/td>\n<td width=\"128\">40 KVA \/ 40 KW<\/td>\n<\/tr>\n<tr>\n<td width=\"87\"><strong>INPUT<\/strong><\/td>\n<td width=\"140\"><\/td>\n<td width=\"118\"><\/td>\n<td colspan=\"4\" width=\"355\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Nominal voltage<\/td>\n<td colspan=\"5\" width=\"473\">3 x 400Vac (Three phase with neutral on earth)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Volt Range<\/td>\n<td colspan=\"5\" width=\"473\">305 &#8211; 478 VAC (F\/F) @ 100% load<\/p>\n<p>190 &#8211; 520 VAC (F\/F) @ 50% load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Range Frequency<\/td>\n<td colspan=\"5\" width=\"473\">46~54 Hz @ 50Hz \/ 56~64 Hz @ 60Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Phases<\/td>\n<td colspan=\"5\" width=\"473\">Three phase with neutral + earth<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Power factor P.F.<\/td>\n<td colspan=\"5\" width=\"473\">\u2265 0.99 @ 100% of load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"700\"><strong>OUTPUT<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Output voltage<\/td>\n<td colspan=\"3\" width=\"237\">3 x 360* &#8211; 380 &#8211; 400 &#8211; 415V Three phase with neutral<\/p>\n<p>1 x 208 \u2013 220 \u2013 230 \u2013 240V single phase<\/td>\n<td colspan=\"2\" width=\"237\">3 x 360* &#8211; 380 &#8211; 400 &#8211; 415V Three phase with neutral<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Tolerance Volt (Batt. Mode)<\/td>\n<td colspan=\"5\" width=\"473\">\u00b1 1%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Frequency (Range of synchronization)<\/td>\n<td colspan=\"5\" width=\"473\">46~54 Hz @ 50 Hz \/ 56~64 Hz @ 60 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Frequency (Range Batt. Mode)<\/td>\n<td colspan=\"5\" width=\"473\">50 Hz \u00b1 0.1 Hz o 60 Hz \u00b1 0.1 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Crest current Ratio<\/td>\n<td colspan=\"5\" width=\"473\">3:1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Harmonic distortion<\/td>\n<td colspan=\"5\" width=\"473\">\u2264 2 % THD (linear load) \u2264 5 % THD (non-linear load)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"87\">Intervention time<\/td>\n<td width=\"140\">Line to battery<\/td>\n<td colspan=\"5\" width=\"473\">Zero<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Inverter to bypass<\/td>\n<td colspan=\"5\" width=\"473\">Zero<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Wave form (Batt. Mode)<\/td>\n<td colspan=\"5\" width=\"473\">PURE SINE WAVE<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"87\">Overload<\/td>\n<td width=\"140\">Line mode<\/td>\n<td colspan=\"5\" width=\"473\">100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;&gt;150% immediate cut-off<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Battery mode<\/td>\n<td colspan=\"5\" width=\"473\">100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;&gt;150% immediate cut-off<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"700\"><strong>EFFICIENCY<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">With present line<\/td>\n<td colspan=\"5\" width=\"473\">95.5%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">With power from eco mode<\/td>\n<td colspan=\"5\" width=\"473\">98%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">With power from batteries<\/td>\n<td colspan=\"5\" width=\"473\">94.5%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"700\"><strong>BATTERY<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\" width=\"87\">Model Standard<\/td>\n<td width=\"140\">Battery type<\/td>\n<td colspan=\"2\" width=\"231\">12 V \/ 9 AH<\/td>\n<td colspan=\"2\" width=\"113\">12 V \/ 7 AH<\/td>\n<td width=\"128\">12 V \/ 9 AH<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Battery number<\/td>\n<td width=\"118\">10+10<\/td>\n<td width=\"113\">16+16<\/td>\n<td colspan=\"3\" width=\"242\">2 \/\/ 16+16<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Typical recharging time<\/td>\n<td colspan=\"5\" width=\"473\">9 ore 90% capacity<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Charge current\u00a0 (max.)<\/td>\n<td colspan=\"5\" width=\"473\">1.0 A ~ 12.0 A adjustable<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Charging Voltage<\/td>\n<td width=\"118\">+\/- 136.5 VDC +\/- 10%<\/td>\n<td colspan=\"4\" width=\"355\">+\/- 218 VDC +\/- 10%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"87\">Model (S) long run<\/td>\n<td width=\"140\">Battery type<\/td>\n<td colspan=\"5\" width=\"473\">It depends on the capacity of the external batteries according to the required autonomy<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">numbers<\/td>\n<td width=\"118\">20<\/td>\n<td colspan=\"4\" width=\"355\">32 ~ 40 adjustable<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Charge current\u00a0 (max.)<\/td>\n<td colspan=\"5\" width=\"473\">1.0 A ~ 12.0 A adjustable<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Charging Voltage<\/td>\n<td width=\"118\">+\/- 136.5 VDC +\/- 10%<\/td>\n<td colspan=\"4\" width=\"355\">+\/- 13.65 VDC +\/- 10% x N (N = 16 ~ 20 batt)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"700\"><strong>INDICATORS<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">display<\/td>\n<td colspan=\"5\" width=\"473\">4.3\u201d colour touch screen, state of UPS, charge level, battery level, Voltage input\/output,<\/p>\n<p>Autonomy, battery, Fault condition<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"700\"><strong>DIMENSIONS AND WEIGHTS<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"87\">Standard Model<\/td>\n<td width=\"140\">Dimensions, D x W x H (mm)<\/td>\n<td colspan=\"2\" width=\"231\">627 X 250 X 827<\/td>\n<td colspan=\"3\" width=\"242\">815 X 300 X 1000<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">weight (kg)<\/td>\n<td width=\"118\">126<\/td>\n<td width=\"113\">141<\/td>\n<td colspan=\"2\" width=\"113\">230<\/td>\n<td width=\"128\">250<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"87\">(S) long run Model<\/td>\n<td width=\"140\">Dimensions, D x W x H (mm)<\/td>\n<td colspan=\"2\" width=\"231\">627 X 250 X 827<\/td>\n<td colspan=\"3\" width=\"242\">815 X 300 X 1000<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">weight (kg)<\/td>\n<td width=\"118\">60<\/td>\n<td width=\"113\">70<\/td>\n<td colspan=\"2\" width=\"113\">90<\/td>\n<td width=\"128\">100<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"700\"><strong>ENVIRONMENTAL DATA<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Operating humidity<\/td>\n<td colspan=\"5\" width=\"473\">0-90 % RH @ 0- 40\u00b0C (without condense)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Noise<\/td>\n<td width=\"118\">&lt; 60dBA @ 1 m<\/td>\n<td colspan=\"4\" width=\"355\">&lt; 65 ~ 70 dB @ 1 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"700\"><strong>INTERFACE<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">USB<\/td>\n<td colspan=\"5\" width=\"473\">Windows family, Linux, Unix and MAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Optional SNMP<\/td>\n<td colspan=\"5\" width=\"473\">Power management per SNMP manager e web browser<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"700\">* When output voltage is adjusted to 3 x 360 VAC, output power will be reduced to 90%<\/p>\n<p>(S) Identify long run models<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"700\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"700\">\n<tbody>\n<tr>\n<td colspan=\"5\" width=\"700\"><strong>EG133 60K\/80K three phase \/ three phase ONLINE UPS DOUBLE CONVERSION<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>MODEL<\/strong><\/td>\n<td colspan=\"2\" width=\"231\"><strong>EG13360K (S) <\/strong><\/td>\n<td width=\"242\"><strong>EG13380K (S) <\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>PHASE<\/strong><\/td>\n<td colspan=\"3\" width=\"473\"><strong>Three phase input \/ three phase output<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>POWER<\/strong><\/td>\n<td colspan=\"2\" width=\"231\">60 KVA \/ 60 KW<\/td>\n<td width=\"242\">80 KVA \/ 80 KW<\/td>\n<\/tr>\n<tr>\n<td width=\"87\"><strong>INPUT<\/strong><\/td>\n<td width=\"140\"><\/td>\n<td width=\"118\"><\/td>\n<td colspan=\"2\" width=\"355\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Nominal Voltage<\/td>\n<td colspan=\"3\" width=\"473\">3 x 400Vac (Three phase with neutral on earth)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Voltage Range<\/td>\n<td colspan=\"3\" width=\"473\">305 &#8211; 478 VAC (F\/F) @ 100% load<\/p>\n<p>190 &#8211; 520 VAC (F\/F) @ 50% load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Frequency Range<\/td>\n<td colspan=\"3\" width=\"473\">46~54 Hz @ 50Hz \/ 56~64 Hz @ 60Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Phase<\/td>\n<td colspan=\"3\" width=\"473\">Three-phase with neutral + earth<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Power factor P.F.<\/td>\n<td colspan=\"3\" width=\"473\">\u2265 0.99\u00a0 @ 100% of charge<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"700\"><strong>OUTPUT<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Output voltage<\/td>\n<td colspan=\"3\" width=\"473\">3 x 360* &#8211; 380 &#8211; 400 &#8211; 415V Three phase with neutral<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Tolerance Volt (Batt. Mode)<\/td>\n<td colspan=\"3\" width=\"473\">\u00b1 1%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Frequency (Range of synchro)<\/td>\n<td colspan=\"3\" width=\"473\">46~54 Hz @ 50 Hz \/ 56~64 Hz @ 60 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Frequency (Range Batt. Mode)<\/td>\n<td colspan=\"3\" width=\"473\">50 Hz \u00b1 0.1 Hz o 60 Hz \u00b1 0.1 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Crest current Ratio<\/td>\n<td colspan=\"3\" width=\"473\">3:1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Harmonic distortion<\/td>\n<td colspan=\"3\" width=\"473\">\u2264 2 % THD (linear load) \u2264 5 % THD (non-linear load)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"87\">Intervention time<\/td>\n<td width=\"140\">Line to battery<\/td>\n<td colspan=\"3\" width=\"473\">Zero<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Inverter to bypass<\/td>\n<td colspan=\"3\" width=\"473\">Zero<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Wave form (Batt. Mode)<\/td>\n<td colspan=\"3\" width=\"473\"><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"87\">Overcharge<\/td>\n<td width=\"140\">Line mode<\/td>\n<td colspan=\"3\" width=\"473\">100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;&gt;150% immediate cut-off<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Battery mode<\/td>\n<td colspan=\"3\" width=\"473\">100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;&gt;150% immediate cut-off<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"700\"><strong>EFFICIENCY<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">With present line<\/td>\n<td colspan=\"3\" width=\"473\">95.5%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">With power from eco mode<\/td>\n<td colspan=\"3\" width=\"473\">98%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">With power from batteries<\/td>\n<td colspan=\"3\" width=\"473\">94.5%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"700\"><strong>BATTERY<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"87\">(S) long run Model<\/td>\n<td width=\"140\">Battery type<\/td>\n<td colspan=\"3\" width=\"473\">It depends on the capacity of the external batteries according to the required autonomy<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">numbers<\/td>\n<td colspan=\"3\" width=\"473\">32 ~ 40 adjustable<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Charge current (max.)<\/td>\n<td colspan=\"3\" width=\"473\">2 A ~ 24 A adjustable<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Charging Voltage<\/td>\n<td colspan=\"3\" width=\"473\">+\/- 13.65 VDC +\/- 10% x N ( N = 16 ~ 20 batt)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"700\"><strong>INDICATORS<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">display<\/td>\n<td colspan=\"3\" width=\"473\">4.3\u201d colour touch screen, state of UPS, charge level, battery level, Voltage input\/output,<\/p>\n<p>Autonomy, battery, Fault condition<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"700\"><strong>DIMENSIONS AND WEIGHTS<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Dimensions, D x W x H (mm)<\/td>\n<td colspan=\"3\" width=\"473\">790 X 360 X 1010<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">weight (kg)<\/td>\n<td colspan=\"2\" width=\"231\">112<\/td>\n<td width=\"242\">117<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"700\"><strong>ENVIRONMENTAL DATA<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Operating humidity<\/td>\n<td colspan=\"3\" width=\"473\">0-90 % RH @ 0- 40\u00b0C (without condensation)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Noise<\/td>\n<td colspan=\"2\" width=\"231\">&lt; 70dBA @ 1 m<\/td>\n<td width=\"242\">&lt; 75 dB @ 1 m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"700\"><strong>INTERFACE<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">USB<\/td>\n<td colspan=\"3\" width=\"473\">Windows family, Linux, Unix and MAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Optional SNMP<\/td>\n<td colspan=\"3\" width=\"473\">Power management per SNMP manager e web browser<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" width=\"700\">* When output voltage is adjusted to 3 x 360 VAC, output power will be reduced to 90%<\/p>\n<p>(S) Identify long run models<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"700\">\n<tbody>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>EF133 60K\/120K Three Phase \/ Three Phase ONLINE UPS DOUBLE CONVERSION<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>MODEL<\/strong><\/td>\n<td width=\"118\"><strong>EF133060K (S)<\/strong><\/td>\n<td width=\"113\"><strong>EF133080K (S)<\/strong><\/td>\n<td width=\"113\"><strong>EF133100K (S)<\/strong><\/td>\n<td width=\"128\"><strong>EF133120K (S)<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>PHASES<\/strong><\/td>\n<td colspan=\"4\" width=\"473\"><strong>Three-phase input \/ three-phase output<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>POWER<\/strong><\/td>\n<td width=\"118\">60 KVA \/ 60 KW<\/td>\n<td width=\"113\">80 KVA \/ 80 KW<\/td>\n<td width=\"113\">100 KVA \/ 100 KW<\/td>\n<td width=\"128\">120 KVA \/ 120 KW<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\"><strong>PARALLELABLE UNITS<\/strong><\/td>\n<td colspan=\"4\" width=\"473\">Max. 4 UPS<\/td>\n<\/tr>\n<tr>\n<td width=\"87\"><strong>INPUT<\/strong><\/td>\n<td width=\"140\"><\/td>\n<td width=\"118\"><\/td>\n<td colspan=\"3\" width=\"355\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Nominal voltage<\/td>\n<td colspan=\"4\" width=\"473\">3 x 400Vac (Three-phase with neutral and ground)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Volt Range<\/td>\n<td colspan=\"4\" width=\"473\">305 &#8211; 478 VAC (F\/F) @ 100% of load<\/p>\n<p>190 &#8211; 520 VAC (F\/F) @ 50% of load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Frequency Range<\/td>\n<td colspan=\"4\" width=\"473\">46~54 Hz @ 50Hz \/ 56~64 Hz @ 60Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Phases<\/td>\n<td colspan=\"4\" width=\"473\">Three-phase with neutral and earth<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Power factor P.F.<\/td>\n<td colspan=\"4\" width=\"473\">&lt; 0.99 @ 100% load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Harmonic distortion (THDi).<\/td>\n<td colspan=\"4\" width=\"473\">\u2264 4 % @ full linear load<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>OUTPUT<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Output voltage<\/td>\n<td colspan=\"4\" width=\"473\">3 x 380 &#8211; 400 &#8211; 415V Three-phase with neutral<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Voltage regulation (Steady state)<\/td>\n<td colspan=\"4\" width=\"473\">\u2264 1% Typical (Load Balanced)<\/p>\n<p>\u2264 2% Typical (non-balanced load)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Frequency (Synchronization Range)<\/td>\n<td colspan=\"4\" width=\"473\">46~54 Hz @ 50 Hz \/ 56~64 Hz @ 60 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Frequency (Range Batt. Mode)<\/td>\n<td colspan=\"4\" width=\"473\">50 Hz \u00b1 0.1 Hz o 60 Hz \u00b1 0.1 Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Crest Current Factor<\/td>\n<td colspan=\"4\" width=\"473\">3:1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Harmonic distortion<\/td>\n<td colspan=\"4\" width=\"473\">\u2264 2 % THD (linear load) \u2264 5 % THD (nonlinear load)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"87\">Intervention time<\/td>\n<td width=\"140\">Line to Battery<\/td>\n<td colspan=\"4\" width=\"473\">Zero<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Da Inverter a Bypass<\/td>\n<td colspan=\"4\" width=\"473\">Zero<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Waveform (Batt. Mode)<\/td>\n<td colspan=\"4\" width=\"473\">PURE SINE<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"87\">Overload<\/td>\n<td width=\"140\">Line Mode<\/td>\n<td colspan=\"4\" width=\"473\">100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min; &gt;150% immediate<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Battery Mode<\/td>\n<td colspan=\"4\" width=\"473\">100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min; &gt;150% immediate<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>EFFICIENCY<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">With network present<\/td>\n<td colspan=\"4\" width=\"473\">95,5%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">With ECOmode operation<\/td>\n<td colspan=\"4\" width=\"473\">98,5%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Battery operated<\/td>\n<td colspan=\"4\" width=\"473\">94,5%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>BYPASS<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Nominal voltage<\/td>\n<td colspan=\"4\" width=\"473\">3 x 380 &#8211; 400 &#8211; 415V Three-phase with neutral<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Voltage Range<\/td>\n<td colspan=\"4\" width=\"473\">-30% &#8211; +20%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Frequency Range<\/td>\n<td colspan=\"4\" width=\"473\">46Hz &#8211; 54Hz or 56Hz &#8211; 64Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Overload<\/td>\n<td colspan=\"4\" width=\"473\">100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min; &gt;150% immediate<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>BATTERY<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"87\">Model(s)<\/p>\n<p>long range<\/td>\n<td width=\"140\">Battery type<\/td>\n<td colspan=\"4\" width=\"473\">Depends on the capacity of the external batteries according to the required autonomy<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Battery quantity<\/td>\n<td colspan=\"4\" width=\"473\">32~40 adjustable<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Charging current (max.)<\/td>\n<td colspan=\"2\" width=\"231\">1.0A~24.0A adjustable<\/td>\n<td colspan=\"2\" width=\"242\">1.0A ~ 2360A adjustable<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Charging voltage<\/td>\n<td colspan=\"4\" width=\"473\">+\/- 13.65 VDC +\/- 10% x N ( N = 16 ~ 20 batt)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>REPORTS<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">LCD Panel<\/td>\n<td colspan=\"4\" width=\"473\">7&#8243; Colour Touch, UPS Status, Load Level, Battery Level, Input\/Output Voltage,<\/p>\n<p>Battery discharge time, Fault condition<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>DIMENSIONS AND WEIGHTS<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"87\">Standard Model<\/td>\n<td width=\"140\">Dimensions, D x W x H (mm)<\/td>\n<td colspan=\"4\" width=\"473\">1000 x 430 x 1200<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Net weight (kg)<\/td>\n<td width=\"118\">169<\/td>\n<td width=\"113\">169<\/td>\n<td width=\"113\">170<\/td>\n<td width=\"128\">170<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>ENVIRONMENTAL DATA<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Operating Humidity<\/td>\n<td colspan=\"4\" width=\"473\">0-90 % RH @ 0- 40\u00b0C (non-condensing)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Altitude **<\/td>\n<td colspan=\"4\" width=\"473\">&lt; 1000 Meters Normal Power<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Noise<\/td>\n<td colspan=\"4\" width=\"473\">&lt; 65 ~ 75 dB @ 1 Metro<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>INTERFACES<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Standard<\/td>\n<td colspan=\"4\" width=\"473\">USB \/ RS232 \/ EPO<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Optional<\/td>\n<td colspan=\"4\" width=\"473\">SNMP \/ RS485 Mod Bus \/ Dry Contacts<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\"><strong>ISTANDARD<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">Safety<\/td>\n<td colspan=\"4\" width=\"473\">IEC\/EN 62040-1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"227\">EMC<\/td>\n<td colspan=\"4\" width=\"473\">IEC\/EN 62040-2 Category C3<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" width=\"700\">Product specifications may be subject to change without notice<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>EG133 is available in capacities from 10KVA to 120 KVA, with on-line double conversion by digital control; for its versatility it is suitable for powering any electrical and electronic system in critical situations; it is possible to use the product as a frequency converter 50 \/ 60Hz or with the use of motor current generators [&hellip;]<\/p>\n","protected":false},"featured_media":13895,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[694,221],"product_tag":[274,329,276,277],"class_list":["post-8405","product","type-product","status-publish","has-post-thumbnail","product_cat-three-phase-static-uninterruptible-power-supplies-en","product_cat-uninterruptible-power-supplies","product_tag-double-conversion-ups","product_tag-double-conversion-ups-2","product_tag-three-phase-on-line-ups","product_tag-uninterruptible-power-supply-3","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","featured","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>EG133 - EF133 - THREE PHASE UPS, DOUBLE CONVERSION SINE WAVE, 10 TO 120KVA - K-factor<\/title>\n<meta name=\"description\" content=\"EG133 three-phase UPS (10-80kVA), online double conversion. Power Factor 1.0, dual mains\/bypass input, and color touch display for advanced monitoring.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"EG133 - EF133 - THREE PHASE UPS, DOUBLE CONVERSION SINE WAVE, 10 TO 120KVA - K-factor\" \/>\n<meta property=\"og:description\" content=\"EG133 three-phase UPS (10-80kVA), online double conversion. Power Factor 1.0, dual mains\/bypass input, and color touch display for advanced monitoring.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-21T11:05:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-eg133_03.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/three-phase-static-uninterruptible-power-supplies-en\\\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/three-phase-static-uninterruptible-power-supplies-en\\\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\\\/\",\"name\":\"EG133 - EF133 - THREE PHASE UPS, DOUBLE CONVERSION SINE WAVE, 10 TO 120KVA - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/three-phase-static-uninterruptible-power-supplies-en\\\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/three-phase-static-uninterruptible-power-supplies-en\\\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-eg133_03.jpg\",\"datePublished\":\"2024-02-18T23:27:25+00:00\",\"dateModified\":\"2026-05-21T11:05:54+00:00\",\"description\":\"EG133 three-phase UPS (10-80kVA), online double conversion. Power Factor 1.0, dual mains\\\/bypass input, and color touch display for advanced monitoring.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/three-phase-static-uninterruptible-power-supplies-en\\\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/three-phase-static-uninterruptible-power-supplies-en\\\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/three-phase-static-uninterruptible-power-supplies-en\\\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-eg133_03.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-eg133_03.jpg\",\"width\":1280,\"height\":720,\"caption\":\"UPS GRUPPI STATICI DI CONTINUITA' TRIFASE\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/uninterruptible-power-supplies\\\/three-phase-static-uninterruptible-power-supplies-en\\\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"PRODUCTS\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"EG133 &#8211; EF133 &#8211; THREE PHASE UPS, DOUBLE CONVERSION SINE WAVE, 10 TO 120KVA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"ELECTRONICS MADE EASY\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"EG133 - EF133 - THREE PHASE UPS, DOUBLE CONVERSION SINE WAVE, 10 TO 120KVA - K-factor","description":"EG133 three-phase UPS (10-80kVA), online double conversion. Power Factor 1.0, dual mains\/bypass input, and color touch display for advanced monitoring.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/","og_locale":"en_US","og_type":"article","og_title":"EG133 - EF133 - THREE PHASE UPS, DOUBLE CONVERSION SINE WAVE, 10 TO 120KVA - K-factor","og_description":"EG133 three-phase UPS (10-80kVA), online double conversion. Power Factor 1.0, dual mains\/bypass input, and color touch display for advanced monitoring.","og_url":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/","og_site_name":"K-factor","article_modified_time":"2026-05-21T11:05:54+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-eg133_03.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/","url":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/","name":"EG133 - EF133 - THREE PHASE UPS, DOUBLE CONVERSION SINE WAVE, 10 TO 120KVA - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-eg133_03.jpg","datePublished":"2024-02-18T23:27:25+00:00","dateModified":"2026-05-21T11:05:54+00:00","description":"EG133 three-phase UPS (10-80kVA), online double conversion. Power Factor 1.0, dual mains\/bypass input, and color touch display for advanced monitoring.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-eg133_03.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-eg133_03.jpg","width":1280,"height":720,"caption":"UPS GRUPPI STATICI DI CONTINUITA' TRIFASE"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/en\/shop\/uninterruptible-power-supplies\/three-phase-static-uninterruptible-power-supplies-en\/eg133-three-phase-ups-double-conversion-sine-wave-10-to-80kva\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"PRODUCTS","item":"https:\/\/www.kfactor.it\/en\/shop\/"},{"@type":"ListItem","position":2,"name":"EG133 &#8211; EF133 &#8211; THREE PHASE UPS, DOUBLE CONVERSION SINE WAVE, 10 TO 120KVA"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"ELECTRONICS MADE EASY","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product\/8405","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media\/13895"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/media?parent=8405"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_brand?post=8405"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_cat?post=8405"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/en\/wp-json\/wp\/v2\/product_tag?post=8405"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}