{"id":15755,"date":"2026-01-09T10:43:51","date_gmt":"2026-01-09T09:43:51","guid":{"rendered":"https:\/\/www.kfactor.it\/shop\/non%20class\u00e9\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/"},"modified":"2026-03-23T20:27:33","modified_gmt":"2026-03-23T19:27:33","slug":"ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/","title":{"rendered":"TTP\/M &#8211; TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E &#8211; SORTIE MONOPHAS\u00c9E"},"content":{"rendered":"<h3 data-path-to-node=\"18\">TTP\/M &#8211; TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA<\/h3>\n<p data-path-to-node=\"18\">ENTR\u00c9E TRIPHAS\u00c9E &#8211; SORTIE MONOPHAS\u00c9E<\/p>\n<p data-path-to-node=\"18\">Les transformateurs triphas\u00e9s de s\u00e9paration K-factor sont fabriqu\u00e9s avec la plus haute qualit\u00e9 et des techniques de construction avanc\u00e9es, disponibles dans diff\u00e9rentes combinaisons de tensions.<\/p>\n<ul data-path-to-node=\"19\">\n<li>\n<p data-path-to-node=\"19,0,0\">Refroidissement naturel dans l&#8217;air type AN, adapt\u00e9s pour une installation en int\u00e9rieur.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"19,1,0\">Enroulements en cuivre \u00e9lectrolytique \u00e9maill\u00e9<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"19,2,0\">Noyau en t\u00f4le magn\u00e9tique \u00e0 faibles pertes<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"19,3,0\">Enroulements impr\u00e9gn\u00e9s de r\u00e9sine<\/p>\n<\/li>\n<\/ul>\n<p id=\"tw-target-text\" class=\"tw-data-text tw-text-large tw-ta\" dir=\"ltr\" tabindex=\"-1\" role=\"text\" data-placeholder=\"Traduzione\" data-ved=\"2ahUKEwjQ5qXHk8-SAxUB8LsIHeuFIaoQ3ewLegQIDxAW\" aria-label=\"Testo tradotto: CARACT\u00c9RISTIQUES \u00c9LECTRIQUES\">CARACT\u00c9RISTIQUES \u00c9LECTRIQUES<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"366\">Puissance nominale :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>da 1kVA a 200kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Tension primaire :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>da 110V a 600V TRIFASE<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Tension secondaire :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>da 50V a 600V MONOFASE<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Fr\u00e9quence :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>50\/60 Hz<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Groupe de couplage standard :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>TRIANGOLO APERTO\/monofase<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Groupe vectoriel CEI standard :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>Dap\/mon<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Niveau d&#8217;isolement (valeur efficace) :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>4.2 kV <\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Courant d&#8217;appel :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>&lt; 15 In<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Tension de court-circuit (Vcc%) :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>&lt;4%<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Classe de temp\u00e9rature :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>F<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Limites d&#8217;\u00e9chauffement max (ta=25\u00b0C) :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>100\u00b0C<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Temp\u00e9ratures ambiantes de r\u00e9f\u00e9rence :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>-5\u00b0C ~ +40\u00b0C<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Niveau de pression acoustique max \u00e0 1m :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>&lt; 60 dB (A)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Humidit\u00e9 relative de l&#8217;air :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>50% ~ 95%<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Altitude de fonctionnement sans d\u00e9classement :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>fino a 1000 m. s.l.m. *<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Indice de protection :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>IP00<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Classe de protection :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>I<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"366\">Normes appliqu\u00e9es :<\/td>\n<td style=\"text-align: center;\" width=\"366\"><strong>CEI EN 61558-2-1<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em><strong>* Pour des installations \u00e0 des altitudes sup\u00e9rieures, il faut pr\u00e9voir une r\u00e9duction de puissance ad\u00e9quate (\u00ab derating \u00bb).<\/strong><\/em><\/p>\n<p>CARACT\u00c9RISTIQUES M\u00c9CANIQUES<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"364\">Anneaux de levage :<\/td>\n<td style=\"text-align: center;\" width=\"364\"><strong>Sur demande<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"364\">Plaque signal\u00e9tique :<\/td>\n<td style=\"text-align: center;\" width=\"364\"><strong>OUI<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"364\">Borne de terre :<\/td>\n<td style=\"text-align: center;\" width=\"364\"><strong>OUI<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b data-path-to-node=\"25\" data-index-in-node=\"0\">NOTE IMPORTANTE SUR LES TRANSFORMATEURS TRI-MONOPHAS\u00c9S :<\/b><\/p>\n<p data-path-to-node=\"25\">Alors que le courant circulant dans les enroulements secondaires est toujours \u00e9gal et correspond \u00e0 celui fourni \u00e0 la charge, le courant primaire n&#8217;est pas \u00e9gal sur les 3 phases : la phase centrale absorbe un courant double par rapport aux deux autres. Il faut donc calculer le courant primaire moyen I1m=I2*(E2\/E1) <i data-path-to-node=\"25\" data-index-in-node=\"372\">(E1=tension primaire de phase, E2=tension secondaire de phase, I2=courant secondaire)<\/i><\/p>\n<p data-path-to-node=\"26\">Par exemple, si nous avons besoin d&#8217;une tension monophas\u00e9e de 220V avec une consommation de 15kVA, et que nous utilisons une alimentation triphas\u00e9e de 400V, le courant au secondaire est I2=68,18 A. Ainsi, le courant moyen au primaire est I1m=68,18*(110\/231)=32,46 A.<\/p>\n<p data-path-to-node=\"26\"><strong>Le courant dans la phase centrale sera I12=I1m<i data-path-to-node=\"26\" data-index-in-node=\"313\">3\/2=31,65<\/i>1,5=48,69 A.<\/strong><\/p>\n<p data-path-to-node=\"26\"><strong> Le courant dans les phases lat\u00e9rales sera I11=I13=I12\/2=24,34 A.<\/strong><\/p>\n<table style=\"height: 28px; background-color: #ffffff;\" width=\"700\">\n<tbody>\n<tr>\n<td>\u00a0<a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpm-01.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3516 size-full\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpm-01.jpg\" alt=\"disegno trasformatori trifase separazione morsettiere\" width=\"320\" height=\"240\" srcset=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpm-01.jpg 320w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpm-01-1280x960.jpg 1280w\" sizes=\"auto, (max-width: 320px) 100vw, 320px\" \/><\/a><\/td>\n<td>\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3515 size-full\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpp-01.jpg\" alt=\"disegno trasformatori trifase separazione bulloni\" width=\"320\" height=\"240\" srcset=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpp-01.jpg 320w, https:\/\/www.kfactor.it\/wp-content\/uploads\/2016\/03\/di-ttpp-01-1280x960.jpg 1280w\" sizes=\"auto, (max-width: 320px) 100vw, 320px\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">B<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b data-path-to-node=\"27\" data-index-in-node=\"0\">Les <a href=\"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/boitiers-pour-transformateurs\/box-metallici-per-trasformatori-serie-sam-ip23-e-ip44\/\">coffrets m\u00e9talliques de la s\u00e9rie SAM<\/a> sont disponibles pour ces produits.<\/b><\/p>\n","protected":false},"excerpt":{"rendered":"<p>TTP\/M &#8211; TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E &#8211; SORTIE MONOPHAS\u00c9E Les transformateurs triphas\u00e9s de s\u00e9paration K-factor sont fabriqu\u00e9s avec la plus haute qualit\u00e9 et des techniques de construction avanc\u00e9es, disponibles dans diff\u00e9rentes combinaisons de tensions. Refroidissement naturel dans l&#8217;air type AN, adapt\u00e9s pour une installation en int\u00e9rieur. Enroulements en cuivre [&hellip;]<\/p>\n","protected":false},"featured_media":15756,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[772,771],"product_tag":[773,774,775,777,776,778,779],"class_list":["post-15755","product","type-product","status-publish","has-post-thumbnail","product_cat-transformateurs-de-puissance-triphases","product_cat-transformateurs-triphases","product_tag-dyn11","product_tag-isolation-galvanique","product_tag-separation-galvanique","product_tag-transformateur-3","product_tag-transformateur","product_tag-transformateurs-de-separation","product_tag-transformateurs-triphases","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","featured","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TTP\/M - TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E - SORTIE MONOPHAS\u00c9E - K-factor<\/title>\n<meta name=\"description\" content=\"Les transformateurs d&#039;isolement triphas\u00e9s K-factor sono fabriqu\u00e9s con la plus haute qualit\u00e9 et des techniques de construction avanc\u00e9es, disponibles in diverses combinaisons de tensions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TTP\/M - TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E - SORTIE MONOPHAS\u00c9E - K-factor\" \/>\n<meta property=\"og:description\" content=\"Les transformateurs d&#039;isolement triphas\u00e9s K-factor sono fabriqu\u00e9s con la plus haute qualit\u00e9 et des techniques de construction avanc\u00e9es, disponibles in diverses combinaisons de tensions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-23T19:27:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2026\/01\/ft1280-ttp-m_01.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-triphases\\\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-triphases\\\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\\\/\",\"name\":\"TTP\\\/M - TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E - SORTIE MONOPHAS\u00c9E - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-triphases\\\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-triphases\\\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/ft1280-ttp-m_01.jpg\",\"datePublished\":\"2026-01-09T09:43:51+00:00\",\"dateModified\":\"2026-03-23T19:27:33+00:00\",\"description\":\"Les transformateurs d'isolement triphas\u00e9s K-factor sono fabriqu\u00e9s con la plus haute qualit\u00e9 et des techniques de construction avanc\u00e9es, disponibles in diverses combinaisons de tensions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-triphases\\\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-triphases\\\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-triphases\\\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/ft1280-ttp-m_01.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/ft1280-ttp-m_01.jpg\",\"width\":1280,\"height\":720,\"caption\":\"trasformatore tri-monofase\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-triphases\\\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Produits\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"TTP\\\/M &#8211; TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E &#8211; SORTIE MONOPHAS\u00c9E\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"THE VOLTAGE YOU NEED\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TTP\/M - TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E - SORTIE MONOPHAS\u00c9E - K-factor","description":"Les transformateurs d'isolement triphas\u00e9s K-factor sono fabriqu\u00e9s con la plus haute qualit\u00e9 et des techniques de construction avanc\u00e9es, disponibles in diverses combinaisons de tensions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/","og_locale":"fr_FR","og_type":"article","og_title":"TTP\/M - TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E - SORTIE MONOPHAS\u00c9E - K-factor","og_description":"Les transformateurs d'isolement triphas\u00e9s K-factor sono fabriqu\u00e9s con la plus haute qualit\u00e9 et des techniques de construction avanc\u00e9es, disponibles in diverses combinaisons de tensions.","og_url":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/","og_site_name":"K-factor","article_modified_time":"2026-03-23T19:27:33+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2026\/01\/ft1280-ttp-m_01.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/","url":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/","name":"TTP\/M - TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E - SORTIE MONOPHAS\u00c9E - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2026\/01\/ft1280-ttp-m_01.jpg","datePublished":"2026-01-09T09:43:51+00:00","dateModified":"2026-03-23T19:27:33+00:00","description":"Les transformateurs d'isolement triphas\u00e9s K-factor sono fabriqu\u00e9s con la plus haute qualit\u00e9 et des techniques de construction avanc\u00e9es, disponibles in diverses combinaisons de tensions.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2026\/01\/ft1280-ttp-m_01.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2026\/01\/ft1280-ttp-m_01.jpg","width":1280,"height":720,"caption":"trasformatore tri-monofase"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-triphases\/ttp-m-trasformatori-trifase-di-separazione-da-1kva-a-200kva-con-ingresso-trifase-e-uscita-monofase\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Produits","item":"https:\/\/www.kfactor.it\/fr\/shop\/"},{"@type":"ListItem","position":2,"name":"TTP\/M &#8211; TRANSFORMATEURS TRIPHAS\u00c9S DE S\u00c9PARATION de 1kVA \u00e0 200kVA ENTR\u00c9E TRIPHAS\u00c9E &#8211; SORTIE MONOPHAS\u00c9E"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"THE VOLTAGE YOU NEED","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product\/15755","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/media\/15756"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/media?parent=15755"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product_brand?post=15755"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product_cat?post=15755"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product_tag?post=15755"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}