{"id":17192,"date":"2024-02-17T00:08:42","date_gmt":"2024-02-16T23:08:42","guid":{"rendered":"https:\/\/www.kfactor.it\/shop\/non%20class\u00e9\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/"},"modified":"2026-02-25T18:26:32","modified_gmt":"2026-02-25T17:26:32","slug":"egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/","title":{"rendered":"T-ONE &#8211; UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, de 10 \u00e0 20KVA"},"content":{"rendered":"<h3>UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, DE 10 \u00c0 20KVA<\/h3>\n<p>T-One est un syst\u00e8me d&#8217;alimentation sans interruption (UPS) On-line double conversion avec entr\u00e9e triphas\u00e9e et sortie monophas\u00e9e.<\/p>\n<p>Il est disponible en 3 puissances : 10KVA \u2013 15KVA \u2013 20KVA.<\/p>\n<p>T-One, avec ses performances \u00e9lev\u00e9es, garantit une s\u00e9curit\u00e9 maximale pour tout type d&#8217;utilisation. Gr\u00e2ce \u00e0 l&#8217;\u00e9cran LCD, il est possible de visualiser les param\u00e8tres de fonctionnement ; l&#8217;ajout d&#8217;une carte Ethernet SNMP permet de surveiller l&#8217;UPS \u00e0 distance.<\/p>\n<p>T-One utilise une recharge intelligente pour pr\u00e9server la dur\u00e9e de vie pr\u00e9vue des batteries ; les batteries sont charg\u00e9es en trois phases, augmentant ainsi leurs performances.<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"188\"><strong>MOD\u00c8LE<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE10<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE15<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE20<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\"><strong>PUISSANCE NOMINALE<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>10KVA \/ 8KW<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>15KVA \/ 12KW<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>20KVA \/ 16KW<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"9\" width=\"32\"><strong>ENTR\u00c9E<\/strong><\/td>\n<td width=\"156\">Entr\u00e9e<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Triphas\u00e9e<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Facteur de puissance<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">\u2265 0.99<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Tension nominale<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">380VAC \/ 400VAC \/ 415VAC (S\u00e9lection automatique)<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Fr\u00e9quence nom.<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">50Hz\/60Hz (S\u00e9lectionnable)<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Plage de tension<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">208 ~ 478Vac<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Plage de fr\u00e9quence<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">45 ~ 55Hz (50Hz) &#8211; 55 ~ 65Hz (60Hz)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"156\">Plage tension Bypass<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">220Vac max : d\u00e9faut +25% (+10%, +15%, +20%) optionnel<\/p>\n<p>230Vac max : d\u00e9faut +20% (+10%, +15%) optionnel<\/p>\n<p>240Vac max : d\u00e9faut +15% (+10%) optionnel<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">min : d\u00e9faut -45%(-20%, -30%) optionnel<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Plage fr\u00e9quence Bypass<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">\u00b11% &#8211; \u00b12% &#8211; \u00b14% &#8211; \u00b15% &#8211; \u00b110%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" width=\"32\"><strong>BATTERIE<\/strong><\/td>\n<td width=\"156\">Nombre de batteries<\/td>\n<td style=\"text-align: center;\" width=\"139\">16 Standard<\/p>\n<p>18\/20 optionnels<\/p>\n<p>(internes)<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"277\">16\/18\/20<\/p>\n<p>(en cabinet externe)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"156\">Type de batterie<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">12V &#8211; 9Ah<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Au plomb \u00e9tanche sans maintenance (VRLA)<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Type de charge<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Charge rapide ou d&#8217;entretien automatique<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Temps de recharge<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Rapide jusqu&#8217;\u00e0 20h (Max)<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Courant de charge maximum<\/td>\n<td style=\"text-align: center;\" width=\"139\">1A<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"277\">10A<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"22\" width=\"32\"><strong>SORTIE<\/strong><\/td>\n<td width=\"156\">Type de sortie<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Monophas\u00e9e<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">R\u00e9gulation tension<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">\u00b11.0%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"156\">Distorsion tension (THD)<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Moins de 2% avec 100% de charge lin\u00e9aire<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Moins de 5% avec 100% de charge non lin\u00e9aire<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Tension nominale<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">220V\/230V\/240Vac \u00b11.0%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"156\">R\u00e9gulation fr\u00e9quence<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">\u00b10.1% (unit\u00e9 simple)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">\u00b10.25% (unit\u00e9s en parall\u00e8le)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"156\">Fr\u00e9quence<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">R\u00e9seau pr\u00e9sent : se synchronise sur celle du r\u00e9seau (Phase A)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">En mode batterie : 50Hz \/ 60Hz \u00b10.1Hz<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"156\">Synchronisation de la fr\u00e9quence<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">1Hz\/s (unit\u00e9 simple)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">0.5Hz\/s (unit\u00e9s en parall\u00e8le)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"156\">Surcharge admise avec r\u00e9seau pr\u00e9sent<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">105 % ~ 110 %, pendant max 1h<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">110% ~ 125%, pendant max 10 min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">125% ~ 150%, pendant max 1 min<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">\uff1e150% commute imm\u00e9diatement sur bypass<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"156\">Surcharge pour le bypass<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Supporte la charge pendant une longue p\u00e9riode si le courant de sortie est inf\u00e9rieur \u00e0 125%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">La surcharge du Bypass est limit\u00e9e par le disjoncteur magn\u00e9tothermique sur la ligne de r\u00e9serve.<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Facteur de cr\u00eate<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">3:1<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Rendement en AC<\/td>\n<td style=\"text-align: center;\" width=\"139\">\u226593.5%<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"277\">\u226594.5%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"156\">R\u00e9ponse dynamique<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">\u00b1 5.0%<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">40ms<\/td>\n<\/tr>\n<tr>\n<td width=\"156\">Composante DC<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">\u2264100mV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"188\"><strong>MOD\u00c8LE<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE10<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE15<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE20<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\"><strong>PUISSANCE NOMINALE<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>10KVA \/ 8KW<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>15KVA \/ 12KW<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>20KVA \/ 16KW<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"47\"><strong>TEMPS DE COMMUTATION<\/strong><\/td>\n<td width=\"141\">Du r\u00e9seau \u00e0 la batterie<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">0ms<\/td>\n<\/tr>\n<tr>\n<td width=\"141\">De l&#8217;onduleur au bypass<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">0ms (synchrone)<\/p>\n<p>&lt;15ms (50Hz), &lt;13.33ms (60Hz) (asynchrone)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">Bruit<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">&lt;55dB (1m)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">\u00c9cran<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">LED + LCD<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">S\u00e9curit\u00e9<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Conforme IEC62040-1<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"3\" width=\"188\">EMI<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Conduction : IEC 62040-2<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Radiation : IEC 62040-2<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Harmoniques : IEC 62040-2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">EMS<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">IEC 62040-2<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">MTBF<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">250,000 heures<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">R\u00e9sistance d&#8217;isolement<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">&gt; 2M\u03a9 (500Vdc)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">Isolement en tension<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">2820Vdc, &lt;3.5mA, 1min<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">Surtensions<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Conforme IEC60664-1 1.2\/50uS+8\/20uS 6KV\/3KA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">Indice de protection<\/td>\n<td colspan=\"3\" width=\"416\">\n<p style=\"text-align: center;\">IP20<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Environnement de travail<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"188\"><strong>MOD\u00c8LE<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE10<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE15<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE20<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"188\">Temp\u00e9rature<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">0\u00b0C ~ 40\u00b0C (hors batteries)<\/td>\n<\/tr>\n<tr>\n<td width=\"188\">Humidit\u00e9 relative<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">0 ~ 95% sans condensation<\/td>\n<\/tr>\n<tr>\n<td width=\"188\">Altitude<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">&lt;1500m (si &gt;1500m la puissance est r\u00e9duite)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Sp\u00e9cifications m\u00e9caniques<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"188\"><strong>MOD\u00c8LE<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE10<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE15<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"139\"><strong>T-ONE20<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"188\">Hauteur (mm)<\/td>\n<td style=\"text-align: center;\" width=\"139\">655<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"277\">616<\/td>\n<\/tr>\n<tr>\n<td width=\"188\">Largeur (mm)<\/td>\n<td style=\"text-align: center;\" width=\"139\">250<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"277\">250<\/td>\n<\/tr>\n<tr>\n<td width=\"188\">Profondeur (mm)<\/td>\n<td style=\"text-align: center;\" width=\"139\">597<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"277\">502<\/td>\n<\/tr>\n<tr>\n<td width=\"188\">Poids (Kg)<\/td>\n<td style=\"text-align: center;\" width=\"139\">76<\/td>\n<td style=\"text-align: center;\" colspan=\"2\" width=\"277\">45<\/td>\n<\/tr>\n<tr>\n<td width=\"188\">Couleur<\/td>\n<td style=\"text-align: center;\" colspan=\"3\" width=\"416\">Noir<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, DE 10 \u00c0 20KVA T-One est un syst\u00e8me d&#8217;alimentation sans interruption (UPS) On-line double conversion avec entr\u00e9e triphas\u00e9e et sortie monophas\u00e9e. Il est disponible en 3 puissances : 10KVA \u2013 15KVA \u2013 20KVA. T-One, avec ses performances \u00e9lev\u00e9es, garantit une s\u00e9curit\u00e9 maximale pour tout type d&#8217;utilisation. Gr\u00e2ce \u00e0 l&#8217;\u00e9cran [&hellip;]<\/p>\n","protected":false},"featured_media":16374,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[837,1043],"product_tag":[841,1045,1003,1046,1044],"class_list":["post-17192","product","type-product","status-publish","has-post-thumbnail","product_cat-onduleurs-ups","product_cat-onduleurs-tri-monophases","product_tag-alimentations-sans-interruption-asi","product_tag-alimentations-sans-interruption-statiques","product_tag-onduleur-2","product_tag-onduleur-tri-monophase","product_tag-onduleurs-tri-monophases","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","featured","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>T-ONE - UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, de 10 \u00e0 20KVA - K-factor<\/title>\n<meta name=\"description\" content=\"Onduleur tri-monophas\u00e9 T-ONE (10-20kVA) on-line double conversion. Entr\u00e9e triphas\u00e9e et sortie monophas\u00e9e avec charge intelligente et surveillance SNMP.Tedesco (DE)\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"T-ONE - UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, de 10 \u00e0 20KVA - K-factor\" \/>\n<meta property=\"og:description\" content=\"Onduleur tri-monophas\u00e9 T-ONE (10-20kVA) on-line double conversion. Entr\u00e9e triphas\u00e9e et sortie monophas\u00e9e avec charge intelligente et surveillance SNMP.Tedesco (DE)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-25T17:26:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-t-one02.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/onduleurs-ups\\\/onduleurs-tri-monophases\\\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/onduleurs-ups\\\/onduleurs-tri-monophases\\\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\\\/\",\"name\":\"T-ONE - UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, de 10 \u00e0 20KVA - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/onduleurs-ups\\\/onduleurs-tri-monophases\\\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/onduleurs-ups\\\/onduleurs-tri-monophases\\\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-t-one02.jpg\",\"datePublished\":\"2024-02-16T23:08:42+00:00\",\"dateModified\":\"2026-02-25T17:26:32+00:00\",\"description\":\"Onduleur tri-monophas\u00e9 T-ONE (10-20kVA) on-line double conversion. Entr\u00e9e triphas\u00e9e et sortie monophas\u00e9e avec charge intelligente et surveillance SNMP.Tedesco (DE)\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/onduleurs-ups\\\/onduleurs-tri-monophases\\\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/onduleurs-ups\\\/onduleurs-tri-monophases\\\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/onduleurs-ups\\\/onduleurs-tri-monophases\\\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-t-one02.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/ft1280-t-one02.jpg\",\"width\":1280,\"height\":720,\"caption\":\"ups tri-monofase\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/onduleurs-ups\\\/onduleurs-tri-monophases\\\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Produits\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"T-ONE &#8211; UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, de 10 \u00e0 20KVA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"THE VOLTAGE YOU NEED\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"T-ONE - UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, de 10 \u00e0 20KVA - K-factor","description":"Onduleur tri-monophas\u00e9 T-ONE (10-20kVA) on-line double conversion. Entr\u00e9e triphas\u00e9e et sortie monophas\u00e9e avec charge intelligente et surveillance SNMP.Tedesco (DE)","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/","og_locale":"fr_FR","og_type":"article","og_title":"T-ONE - UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, de 10 \u00e0 20KVA - K-factor","og_description":"Onduleur tri-monophas\u00e9 T-ONE (10-20kVA) on-line double conversion. Entr\u00e9e triphas\u00e9e et sortie monophas\u00e9e avec charge intelligente et surveillance SNMP.Tedesco (DE)","og_url":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/","og_site_name":"K-factor","article_modified_time":"2026-02-25T17:26:32+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-t-one02.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/","url":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/","name":"T-ONE - UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, de 10 \u00e0 20KVA - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-t-one02.jpg","datePublished":"2024-02-16T23:08:42+00:00","dateModified":"2026-02-25T17:26:32+00:00","description":"Onduleur tri-monophas\u00e9 T-ONE (10-20kVA) on-line double conversion. Entr\u00e9e triphas\u00e9e et sortie monophas\u00e9e avec charge intelligente et surveillance SNMP.Tedesco (DE)","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-t-one02.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/10\/ft1280-t-one02.jpg","width":1280,"height":720,"caption":"ups tri-monofase"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/fr\/shop\/onduleurs-ups\/onduleurs-tri-monophases\/egl3t-ups-tri-monofase-doppia-conversione-onda-sinusoidale-da-10-a-20kva-copia\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Produits","item":"https:\/\/www.kfactor.it\/fr\/shop\/"},{"@type":"ListItem","position":2,"name":"T-ONE &#8211; UPS TRIPHAS\u00c9-MONOPHAS\u00c9, DOUBLE CONVERSION ONDE SINUSO\u00cfDALE, de 10 \u00e0 20KVA"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"THE VOLTAGE YOU NEED","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product\/17192","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/media\/16374"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/media?parent=17192"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product_brand?post=17192"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product_cat?post=17192"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product_tag?post=17192"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}