{"id":17885,"date":"2024-01-11T23:06:59","date_gmt":"2024-01-11T22:06:59","guid":{"rendered":"https:\/\/www.kfactor.it\/shop\/non%20class\u00e9\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/"},"modified":"2026-04-11T10:39:34","modified_gmt":"2026-04-11T08:39:34","slug":"trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva","status":"publish","type":"product","link":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/","title":{"rendered":"TMI &#8211; TRANSFORMATEURS MONOPHAS\u00c9S D&#8217;ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA"},"content":{"rendered":"<h3>TRANSFORMATEURS MONOPHAS\u00c9S D&#8217;ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA<\/h3>\n<table style=\"height: 200px; background-color: #ffffff;\" width=\"700\">\n<tbody>\n<tr>\n<td>Tension primaire standard 230V<br \/>\nEx\u00e9cution ouverte<br \/>\n\u00c9cran \u00e9lectrostatique d&#8217;isolement entre primaire et secondaire \u00e0 la masse<br \/>\nDegr\u00e9 de protection IP00<br \/>\nClasse d&#8217;isolation F (Ta max 35\u00b0C)<br \/>\nFr\u00e9quence 50\/60Hz<br \/>\nEnroulements s\u00e9par\u00e9s en cuivre \u00e9lectrolytique cl. F-H<br \/>\nImpr\u00e9gn\u00e9s de r\u00e9sine et tropicalis\u00e9s<br \/>\nBornes prot\u00e9g\u00e9es pour rail DIN jusqu&#8217;\u00e0 10kVA (ou jusqu&#8217;\u00e0 63A)<br \/>\nConnexions sur boulons en laiton \u00e0 partir de 15kVA ou 64A<br \/>\nPrise de terre sur le ch\u00e2ssis<br \/>\nNormes appliqu\u00e9es EN61558-2-4 \/ EN61558-2-6<br \/>\nPossibilit\u00e9 de commander des articles avec des tensions hors standard sur demande<br \/>\nLes derniers chiffres du code correspondent \u00e0 la combinaison des tensions d&#8217;entr\u00e9e<\/td>\n<td><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2484\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sch-tmi-300x225.jpg\" alt=\"sch\u00e9ma transformateur isolement s\u00e9curit\u00e9 \u00e9cran\" width=\"90\" height=\"68\" \/><\/a><\/td>\n<td><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafosic.gif\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2428\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafosic.gif\" alt=\"symbole transformateur de s\u00e9curit\u00e9\" width=\"41\" height=\"60\" \/><\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafoiso.gif\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2425\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafoiso.gif\" alt=\"symbole transformateur isolement\" width=\"40\" height=\"60\" \/><\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/sim-trafosep.gif\"><br \/>\n<\/a><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/07\/sim-ce.gif\"><img loading=\"lazy\" decoding=\"async\" class=\" size-full wp-image-2352 aligncenter\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/07\/sim-ce.gif\" alt=\"sim-ce\" width=\"57\" height=\"43\" \/><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"height: 213px; background-color: #ffffff;\" width=\"700\">\n<tbody>\n<tr>\n<td>tensions sec.<\/td>\n<td style=\"text-align: center;\">code<\/td>\n<td style=\"text-align: center;\" rowspan=\"6\">\u00a0 \u00a0 <a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/di-te3pduelati.gif\"><br \/>\n<\/a><\/td>\n<\/tr>\n<tr>\n<td>12-24V<\/td>\n<td style=\"text-align: center;\">030<\/td>\n<\/tr>\n<tr>\n<td>24-48V<\/td>\n<td style=\"text-align: center;\">031<\/td>\n<\/tr>\n<tr>\n<td>55-110V<\/td>\n<td style=\"text-align: center;\">032<\/td>\n<\/tr>\n<tr>\n<td>110-220V<\/td>\n<td style=\"text-align: center;\">033<\/td>\n<\/tr>\n<tr>\n<td>230V<\/td>\n<td style=\"text-align: center;\">636<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"height: 294px;\" width=\"700\">\n<tbody>\n<tr>\n<td style=\"text-align: center;\">puissance VA<\/td>\n<td style=\"text-align: center;\">code<\/td>\n<td style=\"text-align: center;\">pertes W<\/td>\n<td style=\"text-align: center;\">Ucc %<\/td>\n<td style=\"text-align: center;\">a<\/td>\n<td style=\"text-align: center;\">b<\/td>\n<td style=\"text-align: center;\">c<\/td>\n<td style=\"text-align: center;\">d<\/td>\n<td style=\"text-align: center;\">e<\/td>\n<td style=\"text-align: center;\">f<\/td>\n<td style=\"text-align: center;\">dessin<\/td>\n<td style=\"text-align: center;\">kg<\/td>\n<td style=\"text-align: center;\">box<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">3150<\/td>\n<td style=\"text-align: center;\">TMI249&#8230;<\/td>\n<td style=\"text-align: center;\">130<\/td>\n<td style=\"text-align: center;\">3.5<\/td>\n<td style=\"text-align: center;\">240<\/td>\n<td style=\"text-align: center;\">230<\/td>\n<td style=\"text-align: center;\">320<\/td>\n<td style=\"text-align: center;\">200<\/td>\n<td style=\"text-align: center;\">125<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">34<\/td>\n<td style=\"text-align: center;\">SAM02<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">4000<\/td>\n<td style=\"text-align: center;\">TMI267&#8230;<\/td>\n<td style=\"text-align: center;\">145<\/td>\n<td style=\"text-align: center;\">2.9<\/td>\n<td style=\"text-align: center;\">240<\/td>\n<td style=\"text-align: center;\">240<\/td>\n<td style=\"text-align: center;\">320<\/td>\n<td style=\"text-align: center;\">200<\/td>\n<td style=\"text-align: center;\">135<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">38<\/td>\n<td style=\"text-align: center;\">SAM02<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">5000<\/td>\n<td style=\"text-align: center;\">TMI287&#8230;<\/td>\n<td style=\"text-align: center;\">180<\/td>\n<td style=\"text-align: center;\">2.7<\/td>\n<td style=\"text-align: center;\">240<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<td style=\"text-align: center;\">320<\/td>\n<td style=\"text-align: center;\">200<\/td>\n<td style=\"text-align: center;\">145<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">44<\/td>\n<td style=\"text-align: center;\">SAM02<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">6300<\/td>\n<td style=\"text-align: center;\">TMI307&#8230;<\/td>\n<td style=\"text-align: center;\">200<\/td>\n<td style=\"text-align: center;\">2.7<\/td>\n<td style=\"text-align: center;\">280<\/td>\n<td style=\"text-align: center;\">230<\/td>\n<td style=\"text-align: center;\">400<\/td>\n<td style=\"text-align: center;\">220<\/td>\n<td style=\"text-align: center;\">145<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">49<\/td>\n<td style=\"text-align: center;\">SAM03<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">8000<\/td>\n<td style=\"text-align: center;\">TMI347&#8230;<\/td>\n<td style=\"text-align: center;\">210<\/td>\n<td style=\"text-align: center;\">2.7<\/td>\n<td style=\"text-align: center;\">280<\/td>\n<td style=\"text-align: center;\">240<\/td>\n<td style=\"text-align: center;\">400<\/td>\n<td style=\"text-align: center;\">220<\/td>\n<td style=\"text-align: center;\">155<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">60<\/td>\n<td style=\"text-align: center;\">SAM03<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">10000<\/td>\n<td style=\"text-align: center;\">TMI387&#8230;<\/td>\n<td style=\"text-align: center;\">280<\/td>\n<td style=\"text-align: center;\">2.5<\/td>\n<td style=\"text-align: center;\">280<\/td>\n<td style=\"text-align: center;\">250<\/td>\n<td style=\"text-align: center;\">400<\/td>\n<td style=\"text-align: center;\">220<\/td>\n<td style=\"text-align: center;\">165<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">65<\/td>\n<td style=\"text-align: center;\">SAM03<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">15000<\/td>\n<td style=\"text-align: center;\">TMI427&#8230;<\/td>\n<td style=\"text-align: center;\">400<\/td>\n<td style=\"text-align: center;\">2.5<\/td>\n<td style=\"text-align: center;\">320<\/td>\n<td style=\"text-align: center;\">260<\/td>\n<td style=\"text-align: center;\">450<\/td>\n<td style=\"text-align: center;\">260<\/td>\n<td style=\"text-align: center;\">185<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">B<\/td>\n<td style=\"text-align: center;\">92<\/td>\n<td style=\"text-align: center;\">SAM04<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">20000<\/td>\n<td style=\"text-align: center;\">TMI467&#8230;<\/td>\n<td style=\"text-align: center;\">600<\/td>\n<td style=\"text-align: center;\">2.4<\/td>\n<td style=\"text-align: center;\">320<\/td>\n<td style=\"text-align: center;\">280<\/td>\n<td style=\"text-align: center;\">450<\/td>\n<td style=\"text-align: center;\">260<\/td>\n<td style=\"text-align: center;\">205<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">B<\/td>\n<td style=\"text-align: center;\">116<\/td>\n<td style=\"text-align: center;\">SAM04<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">25000<\/td>\n<td style=\"text-align: center;\">TMI507&#8230;<\/td>\n<td style=\"text-align: center;\">700<\/td>\n<td style=\"text-align: center;\">2.1<\/td>\n<td style=\"text-align: center;\">320<\/td>\n<td style=\"text-align: center;\">280<\/td>\n<td style=\"text-align: center;\">450<\/td>\n<td style=\"text-align: center;\">260<\/td>\n<td style=\"text-align: center;\">205<\/td>\n<td style=\"text-align: center;\">12<\/td>\n<td style=\"text-align: center;\">B<\/td>\n<td style=\"text-align: center;\">131<\/td>\n<td style=\"text-align: center;\">SAM04<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"height: 28px; background-color: #ffffff;\" width=\"700\">\n<tbody>\n<tr>\n<td><a href=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/di-mc.gif\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-2487\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/di-mc-300x225.gif\" alt=\"dessin transformateurs isolement borniers\" width=\"300\" height=\"225\" \/><\/a><\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-2486\" src=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2015\/10\/di-mcpiastra-300x225.gif\" alt=\"dessin transformateurs isolement plaque de raccordement\" width=\"300\" height=\"225\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">A<\/td>\n<td style=\"text-align: center;\">B<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>TRANSFORMATEURS MONOPHAS\u00c9S D&#8217;ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA Tension primaire standard 230V Ex\u00e9cution ouverte \u00c9cran \u00e9lectrostatique d&#8217;isolement entre primaire et secondaire \u00e0 la masse Degr\u00e9 de protection IP00 Classe d&#8217;isolation F (Ta max 35\u00b0C) Fr\u00e9quence 50\/60Hz Enroulements s\u00e9par\u00e9s en cuivre \u00e9lectrolytique cl. F-H Impr\u00e9gn\u00e9s de r\u00e9sine et tropicalis\u00e9s Bornes prot\u00e9g\u00e9es pour [&hellip;]<\/p>\n","protected":false},"featured_media":17850,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[798,831],"product_tag":[1163,1101,777,776,1152],"class_list":["post-17885","product","type-product","status-publish","has-post-thumbnail","product_cat-transformateurs-monophases","product_cat-transformateurs-monophases-disolement-et-de-securite","product_tag-isolamento","product_tag-monophase","product_tag-transformateur-3","product_tag-transformateur","product_tag-transformateurs-de-securite","has-post-title","has-post-date","has-post-category","has-post-tag","has-post-comment","has-post-author","","first","instock","featured","taxable","shipping-taxable","product-type-variable"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TMI - TRANSFORMATEURS MONOPHAS\u00c9S D&#039;ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA - K-factor<\/title>\n<meta name=\"description\" content=\"Transformateurs monophas\u00e9s d&#039;isolement et de s\u00e9curit\u00e9 s\u00e9rie TMI (3,15-25kVA). Avec \u00e9cran \u00e9lectrostatique, ex\u00e9cution ouverte IP00 et conformes aux normes EN61558-2-4\/2-6.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TMI - TRANSFORMATEURS MONOPHAS\u00c9S D&#039;ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA - K-factor\" \/>\n<meta property=\"og:description\" content=\"Transformateurs monophas\u00e9s d&#039;isolement et de s\u00e9curit\u00e9 s\u00e9rie TMI (3,15-25kVA). Avec \u00e9cran \u00e9lectrostatique, ex\u00e9cution ouverte IP00 et conformes aux normes EN61558-2-4\/2-6.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/\" \/>\n<meta property=\"og:site_name\" content=\"K-factor\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-11T08:39:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-monophases\\\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\\\/\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-monophases\\\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\\\/\",\"name\":\"TMI - TRANSFORMATEURS MONOPHAS\u00c9S D'ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA - K-factor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-monophases\\\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-monophases\\\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-tmi.jpg\",\"datePublished\":\"2024-01-11T22:06:59+00:00\",\"dateModified\":\"2026-04-11T08:39:34+00:00\",\"description\":\"Transformateurs monophas\u00e9s d'isolement et de s\u00e9curit\u00e9 s\u00e9rie TMI (3,15-25kVA). Avec \u00e9cran \u00e9lectrostatique, ex\u00e9cution ouverte IP00 et conformes aux normes EN61558-2-4\\\/2-6.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-monophases\\\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-monophases\\\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-monophases\\\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-tmi.jpg\",\"contentUrl\":\"https:\\\/\\\/www.kfactor.it\\\/wp-content\\\/uploads\\\/2024\\\/04\\\/ft1280-tmi.jpg\",\"width\":1280,\"height\":720,\"caption\":\"trasformatore monofase isolamento\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/transformateurs-electriques\\\/transformateurs-monophases\\\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Produits\",\"item\":\"https:\\\/\\\/www.kfactor.it\\\/fr\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"TMI &#8211; TRANSFORMATEURS MONOPHAS\u00c9S D&#8217;ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.kfactor.it\\\/#website\",\"url\":\"https:\\\/\\\/www.kfactor.it\\\/\",\"name\":\"K-factor\",\"description\":\"THE VOLTAGE YOU NEED\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.kfactor.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TMI - TRANSFORMATEURS MONOPHAS\u00c9S D'ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA - K-factor","description":"Transformateurs monophas\u00e9s d'isolement et de s\u00e9curit\u00e9 s\u00e9rie TMI (3,15-25kVA). Avec \u00e9cran \u00e9lectrostatique, ex\u00e9cution ouverte IP00 et conformes aux normes EN61558-2-4\/2-6.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/","og_locale":"fr_FR","og_type":"article","og_title":"TMI - TRANSFORMATEURS MONOPHAS\u00c9S D'ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA - K-factor","og_description":"Transformateurs monophas\u00e9s d'isolement et de s\u00e9curit\u00e9 s\u00e9rie TMI (3,15-25kVA). Avec \u00e9cran \u00e9lectrostatique, ex\u00e9cution ouverte IP00 et conformes aux normes EN61558-2-4\/2-6.","og_url":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/","og_site_name":"K-factor","article_modified_time":"2026-04-11T08:39:34+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/","url":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/","name":"TMI - TRANSFORMATEURS MONOPHAS\u00c9S D'ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA - K-factor","isPartOf":{"@id":"https:\/\/www.kfactor.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/#primaryimage"},"image":{"@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/#primaryimage"},"thumbnailUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg","datePublished":"2024-01-11T22:06:59+00:00","dateModified":"2026-04-11T08:39:34+00:00","description":"Transformateurs monophas\u00e9s d'isolement et de s\u00e9curit\u00e9 s\u00e9rie TMI (3,15-25kVA). Avec \u00e9cran \u00e9lectrostatique, ex\u00e9cution ouverte IP00 et conformes aux normes EN61558-2-4\/2-6.","breadcrumb":{"@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/#primaryimage","url":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg","contentUrl":"https:\/\/www.kfactor.it\/wp-content\/uploads\/2024\/04\/ft1280-tmi.jpg","width":1280,"height":720,"caption":"trasformatore monofase isolamento"},{"@type":"BreadcrumbList","@id":"https:\/\/www.kfactor.it\/fr\/shop\/transformateurs-electriques\/transformateurs-monophases\/trasformatori-monofase-di-isolamento-serie-tmi-da-3-15-a-25kva\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Produits","item":"https:\/\/www.kfactor.it\/fr\/shop\/"},{"@type":"ListItem","position":2,"name":"TMI &#8211; TRANSFORMATEURS MONOPHAS\u00c9S D&#8217;ISOLEMENT et de S\u00c9CURIT\u00c9 de 3.15 kVA \u00e0 25 kVA"}]},{"@type":"WebSite","@id":"https:\/\/www.kfactor.it\/#website","url":"https:\/\/www.kfactor.it\/","name":"K-factor","description":"THE VOLTAGE YOU NEED","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.kfactor.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product\/17885","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/media\/17850"}],"wp:attachment":[{"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/media?parent=17885"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product_brand?post=17885"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product_cat?post=17885"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kfactor.it\/fr\/wp-json\/wp\/v2\/product_tag?post=17885"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}