Skip to content

EG1-FC – SINGLE PHASE FREQUENCY CONVERTER FROM 0.8KW TO 6KW

The EG1 series is available in ratings from 0.8 KVA to 6 KVA single phase with dual-controlled On-Line technology. This 50/60Hz frequency converter, for its versatility, is suitable to supply any electrical and electronic system even in situations or in combination with the use of motor-powered power generators

Features

A true double conversion frequency converter that provides a perfect current, for a proper high-quality supply of all devices that require power with different frequencies or network voltages.

POWER FACTOR 1  

Comparing this line of ON-LINE frequency converters with competition in the current market, we can say that EG1 systems have the best Power Factor output equal to 1. They Provide high performance and efficiency for critical applications.

LARGE INPUT RANGE (110 V -300 V)

EG1 is able to provide stable and clean current to the equipment connect even in very critical and unstable environments

50/60 HZ FREQUENCY CONVERTER FUNCTION

Blocks the output frequency at 50Hz or 60Hz regardless of the incoming frequency and deletes the By-Pass available in the UPS version of the system

(EPO) Emergency Power Off function

This function is used for the emergency switch off in case of fire and other emergency situations.

CONTEMPORARY OPERATION of SNMP-USB-RS232

This feature allows you to use communication from all USB ports, RS-232 and SNMP simultaneously (optional SNMP card).

Model EG101K-FC EG101.5K-FC EG102K-FC EG103K-FC
Power 800VA – 800W 1200 VA / 1200 W 1600 VA / 1600 W 2400 VA / 2400 W
Input
Rated voltage 200-208-220-230-240V (or 110V/115V/120V or others on demand)
Voltage Range Turn off low/high line  110VAC / 300VAC ± 3 % @ 50% load

160VAC / 300VAC ± 3 % @ 100% load

Frequency Range 40 Hz : 70 Hz
Phases single-phase with Neutral + earth
Power factor P. F. ≧ 0.99 @ rated voltage (100% load)
Output
Rated voltage 200/208/220/230/240Vac (or 110V/115V/120V or others on demand)
Voltage Tolerance ± 1%
Frequency 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz (to be defined at the time of order)
Crest Factor 3:1
Harmonic distortion < 2 % THD (Linear Load)

< 4% THD (nonlinear load)

Waveform

PURE SINEWAVE

Efficiency
With network present > 89% > 91%
Signals
LCD Panel

Converter state, Load level, input/output voltage, failure condition

Alarms
Overload Double sound every second
Fault Continuous sound
DIMENSIONS AND WEIGHT
Tower format Size, D x W x H (mm) 397 X 145 X 220 421 X 190 X 318
Net weight (kg) 7.0 *** 12.3 ***
ENVIRONMENTAL DATA
Operational humidity 20-90%RH @ 0:40°C (No condensation)
Noise < 50dBA @ 1 Meter
Interfaces
Smart RS-232/USB Windows family, Linux, Mac
Optional SNMP Power management per SNMP manager e web browser

* An additional code based on the input/output voltages completes the product code

* Input voltages – output other than 230V may result in a derating of the product

** The factory-set output frequency is not reprogrammable by the user

*** weights are referred to the 230V input/exit model – weights may vary depending on input/output voltages

                                MODEL EG106K-FC EG110K-FC
Phases Input Single Phase / Output Single-Phase
Rated Power 3600VA / 3600W 6000VA / 6000W
10’ rated power 3960VA / 3960W 6600VA / 6600W
1’ rated power 4680VA / 4680W 7800VA / 7800W
Input
Rated voltage

230V (or 110V/115V/120V or other on demand)

Voltage Range Turn off low line 176 VAC @ 100% of the load

110 VAC @ 50% of the load

Return from deactivation 186 VAC @ 100% of the load

120 VAC @ 50% of the load

Turn off high line  300 VAC
Return from deactivation  290 VAC
Frequency Range 46-54 Hz @  50Hz / 56-64 Hz  @  60Hz
Power factor P.F.  > 0.99 @ 100% load
Output
Rated voltage 200/208/220/230/240V (or 110V/115V/120V or other on demand)
Voltage Tolerance ± 1%
Frequency 50 Hz ±0.1Hz or 60 Hz ±1Hz (to be defined at the time of order)
Crest Factor 3:1
Harmonic distortion 2% THD (linear load)

4% THD (nonlinear load)

Waveform PURE SINEWAVE
Efficiency
With network present

94%

Signals
LCD Panel

Converter Status, Load Level, Input/Output voltage, Fault Condition

Alarms
Overload (overhead) Double sound every second
Fault Continuous sound
DIMENSIONS AND WEIGHT
Tower format Size, D x W x H (mm) 592 X 250 X 576
Net weight (kg) 30 *** 30 ***
ENVIRONMENTAL DATA
Operational humidity 20-90 % RH @ 0- 40°C(no condensation)
Noise < 55dBA @ 1 m < 58dB @ 1 m
Interfaces
Smart RS-232 Windows family, Linux, Mac
USB
Optional SNMP Power management per SNMP manager e web browser

 * An additional code based on the input/output voltages completes the product code

* Input voltages – output other than 230V may result in a derating of the product

** The factory-set output frequency is not reprogrammable by the user

*** weights are referred to the 230V input/exit model – weights may vary depending on input/output voltages

WhatsApp
Invia con WhatsApp
GDPR Cookie Consent with Real Cookie Banner