SAC – SINE WAVE EMERGENCY (UPS) POWER SUPPLY MV/LV SUBSTATIONS IN ACCORDANCE WITH CEI 0-16

SINE WAVE EMERGENCY (UPS) POWER SUPPLY MV/LV SUBSTATIONS IN ACCORDANCE WITH CEI 0-16

The SAC series is a range of substation emergency power supplies available in 1 – 2 – 3 – 6 – 10 KVA models, with ON-LINE double conversion (VFI) technology and sinusoidal absorption

SAC ensures that the load is supplied with stabilized voltage and frequency, without interruption.

With wide input voltage tolerance, it significantly reduces battery usage preserving its durability.

The SAC series rescuers are designed for the power supply of critical devices, typical of the industrial environment (in particular MV cabins).

FEATURES

DOUBLE CONVERSION

A DOUBLE CONVERSION continuity system that will provide perfect voltage, for complete high-quality protection for your sensitive devices

POWER OUTPUT FACTOR φ 0.9

Comparing this line of ON-LINE Rescuers with the competition on the current market, we can say that the SACs have the best output Power Factor 0.9. Offer high throughput and high efficiency for critical applications

WIDE INPUT RANGE (110 V -300 V)

SAC is able to provide stable and clean current to connected equipment even in very critical and unstable environments.

FUNCTION (EPO) Emergency Power Off

This function is used to extinguish the SAC by the personnel in charge in the event of a fire or other emergency situation.

SIMPLIFIED INSTALLATION

SAC rescuers come with charged batteries and ready to use. The connection is therefore very simple and does not require the intervention of specialized technicians.

For critical applications, we recommend externally creating a manual Bypass circuit so that SAC can be replaced without creating interruptions to the load.

The device is equipped with an intuitive LCD control panel for displaying the operating condition and any anomalies.

Battery efficiency testing can also be carried out.

BY-PASS MAINTENANCE MANUAL

The manual By-Pass ensures the absence of voltages inside SAC for maintenance interventions, ensuring power supply to the connected equipment.

COMMUNICATION

Communication accessories are available for interfacing with supervision systems (relay boards, ethernet, ModBus and related software).

Controls the automatic and scheduled shutdown of Windows and Linux applications.

It can be downloaded free of charge from the website:

www.power-software-download.com

USB cable included in the package.

SAC IS EQUIPPED WITH A POWER RESERVE FOR RESETTING THE LOAD AFTER THE END OF THE EXPECTED AUTONOMY.

  • The battery rescuer must be switched on again to power the DG before the general disconnector is closed.
  • Thermal protections are integrated inside the appliance.
  • Additional battery modules are available as an option to extend the range

FOR CABIN AUXILIARIES, THE CEI 0-16 STANDARD PROVIDES FOR THE UNINTERRUPTED POWER SUPPLY OF THE

COMMAND OF THE PG AND DG.

The power failure coil and the control circuits of the PG and DG must be powered by the same auxiliary voltage coming from the Rescuer (UPS) or backup batteries with an autonomy of 60 minutes. In the event of a long interruption due to maintenance or breakdown, the DG must be resupplied by suitably trained personnel. Before closing the main disconnector, it is necessary to supply the DG with power.

The following protections are required:

  • Mains interruptions due to poor maintenance to the user’s circuit
  • Untimely trips of the DG due to faults in the trip circuit
  • Indication of the alarm condition for DG trip due to power failure
SAC 01K/02K/03K single-phase ONLINE DOUBLE CONVERSION
MODEL SAC01K SAC02K SAC03K
POWER RATING 1000 VA / 1000 W 2,000 VA / 2,000 W 3,000 VA / 3,000 W
ENTRANCE
Voltage range From 160Vac to 300Vac
Frequency range 45 Hz ~ 65 Hz
Stages Single Phase with Neutral
Power factor P. F. ≧ 0.95
EXIT
Output voltage 200-208-220-230-240V
Tolleranza Volt (Batt. Mode) ± 3%
Frequency (Range Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Overload 130% for 1 second
Crest Current Factor 3:1
Harmonic distortion ≦ 3 % THD (linear load)

≦ 6 % THD (Nonlinear Load)

≦ 4 % THD (linear load)

≦ 7 % THD (Nonlinear Load)

Intervention time Line to Battery Zero
Da Inverter a Bypass 4 ms (Typical)
D’onda Shape (Battery Mode) PURE SINE
EFFICIENCY
With network present ~ 85% ~ 88%
Battery operated ~ 83%
BATTERY
Battery Type 12V / 7 Ah 12V / 9 Ah
Battery quantity 3 6
Typical Range 116 min. with 50W 155 min. with 100W 120 min. with 150W
Charging current (max.) 1.0 A
Charging voltage 41.0 VDC ± 1% 82.1 VDC ±1%
REPORTS
LCD Panel Rescuer Status, Load Level, Battery Level, Input/Output Voltage, Battery Discharge Time, Fault Condition
ALARMS
Battery operation Sound every 4 seconds
Low Battery I play every second
Overload Double sound every second
Breakdown Continuous sound
DIMENSIONS AND WEIGHTS
Tower format Dimensions, D x W x H (mm) 397 x 145 x 220 421 x 190 x 318
Net weight (kg) 13.2 28.1
ENVIRONMENTAL DATA
Operating Humidity 20-90 % RH @ 0- 40°C (Non-condensing)
Noise < 45dBA @ 1 Metro
INTERFACES
Smart RS-232/USB Windows family, Linux, Unix, Mac
Optional SNMP Power management per SNMP manager e web browser
* Product specifications may be subject to change without notice

 

SAC 06K/10K single-phase ONLINE DOUBLE CONVERSION
MODEL SAC06K SAC10K
POWER RATING 6,000 VA / 6,000 W 10,000 VA / 10,000 W
ENTRANCE
Voltage range From 160Vac to 300Vac
Frequency Range 45~65 Hz
Stages Single Phase with Neutral
Power factor P.F. ≧ 0.95
EXIT
Output voltages 200-208-220-230-240V
Tolleranza Volt (Battery Mode) ± 3%
Frequency (Range Battery mode) 50Hz±0.25Hz / 60Hz ±0.3Hz
Crest Current Factor 3:1
Harmonic distortion ≦ 2 % THD (linear load) –  ≦ 6 % THD (non-linear load)
Intervention time Line to Battery Zero
Da Inverter a Bypass Zero
Forma d’onda (Battery Mode) PURE SINE
EFFICIENCY
With network present 90%
Battery operated 88%
BATTERY
Battery Type 12V/7AH
Autonomy 250 min. with 350W
Charging current (max.) 1.0 A
Charging voltage 273.0 VDC
REPORTS
LCD Panel Rescuer Status, Load Level, Battery Level, Input/Output Voltage, Battery Discharge Time, Fault Condition
ALARMS
Battery operation Sound every 4 seconds
Low Battery I play every second
Overload Double sound every second
Breakdown Continuous sound
DIMENSIONS AND WEIGHTS
Tower format Dimensions, D x W x H (mm) 592 x 250 x 576
Net weight (kg) 81
ENVIRONMENTAL DATA
Operating Humidity 20-90 % RH @ 0- 40°C (non-condensing)
Noise < 45dBA @ 1 Metro
INTERFACES
Smart RS-232 Windows family, Linux Unix e Mac
USB
Optional SNMP Power management per SNMP manager e web browser
* Product specifications may be subject to change without notice
SAC 06K/10K single-phase ONLINE DOUBLE CONVERSION
MODEL SAC06K SAC10K
RATED POWER 6,000 VA / 6,000 W 10,000 VA / 10,000 W
INPUT
Voltage Range From 160Vac to 300Vac
Frequency Range 45~65 Hz
Phases Single-phase with Neutral
Power Factor (P.F.) ≧ 0.95
OUTPUT
Output Voltages 200-208-220-230-240V
Voltage Tolerance (Battery Mode) ± 3%
Frequency (Battery Mode Range) 50 Hz ± 0.25Hz / 60 Hz ± 0.3Hz
Current Crest Factor 3:1
Harmonic Distortion ≦ 2 % THD (linear load) – ≦ 6 % THD (non-linear load)
Transfer Time Line to Battery Zero
Inverter to Bypass Zero
Waveform (Battery Mode) PURE SINE WAVE
EFFICIENCY
AC Mode (Mains) 90%
Battery Mode 88%
BATTERY
Battery Type 12V / 7AH
Backup Time 250 min. at 350W
Charging Current (max.) 1.0 A
Charging Voltage 273.0 VDC
INDICATORS
LCD Panel Emergency Unit Status, Load Level, Battery Level, Input/Output Voltage, Battery Discharge Time, Fault Condition
ALARMS
Battery Mode Beep every 4 seconds
Low Battery Beep every second
Overload Double beep every second
Fault Continuous sound
DIMENSIONS AND WEIGHTS
Tower Format Dimensions, D x W x H (mm) 592 X 250 X 576
Net Weight (kg) 81
ENVIRONMENTAL DATA
Operating Humidity 20-90 % RH @ 0- 40°C (Non-condensing)
Noise Level < 45dBA @ 1 Meter
INTERFACES
Smart RS-232 Windows family, Linux, Unix, and Mac
USB
Optional SNMP Power management via SNMP manager and web browser
* Product specifications are subject to change without notice
WhatsApp
Invia con WhatsApp
GDPR Cookie Consent with Real Cookie Banner