ERT1-FC – SINGLE PHASE FREQUENCY CONVERTERS FROM 0.8KVA TO 8KVA

convertitore di frequenza rack 19"
frequency converter rack 19″

ERT1-FC – SINGLE PHASE FREQUENCY CONVERTERS FROM 0.8KVA TO 8KVA

The ERT1 CONVERTIBLE RACK series is available in powers from 0.8 KVA to 8 KVA with digitally controlled On-Line double conversion technology. This series, due to its versatility, is suitable for converting the 50/60Hz frequency to power any electrical and electronic system even in critical situations

  • DOUBLE CONVERSION FREQUENCY CONVERTER

A true DOUBLE CONVERSION frequency converter that will provide perfect current, for complete high quality protection for your sensitive devices, such as PC networks (Networks), Small Data Centers, Servers, Telecommunications, Healthcare/Hospital Equipment, and in industrial applications in general.

It is necessary to communicate whether the conversion must be carried out from 50Hz to 60Hz or vice versa, to carry out the factory setting.

It is possible to request input or output voltages other than 230V, such as 115V, 208V or others on request

  • POWER OUTPUT FACTOR φ 1.0

Comparing this line with the competition in the market, we can say that EGRT drives have the best output Power Factor 1.0. Offer high performance and efficiency for critical applications

  • FUNCTION (EPO) Emergency Power Off

This function is used to turn off the UPS by the personnel in charge in the event of a fire and other emergency situation.

  • SNMP+USB+RS-232 SIMULTANEOUS OPERATION

This feature allows you to use communication from all USB, RS-232 and SNMP ports simultaneously (SNMP card optional).

  • RACK 19” / TOWER design

The EGRT series can be installed in a 19″ RACK or TOWER version, with the easy rotation of the LCD display

  • Power Factor Correction fino a 0.99

PFC improves the quality of the absorbed current and increases energy efficiency, with consequent cost savings

12 MONTH WARRANTY

MODEL ERT101K-FC ERT101.5K-FC ERT102K-FC ERT103K-FC
POWER 800VA/800W 1200VA/1200W 1600VA/1600W 2400VA/2400W
INPUT DATA
Rated voltage 230Vac single-phase (OR OTHERS ON REQUEST)
Frequency range 40Hz : 70Hz ±5%
No. Of phases Single-phase with neutral
PF Power Factor ≥ 0.99 to rated voltage (100% load)
OUTPUT DATA
Voltage 230Vac single-phase (OR OTHERS ON REQUEST)
Frequency (range battery mode) 50Hz ± 0.1Hz o 60Hz ± 0.1Hz
Crest Factor 3 : 1
Harmonic distortion ≤ 2% THD (linear load) ≤ 4% THD (nonlinear load)
Wave form PURE SINE (distortion in relation to the electrical network)
EFFICIENCY
With network present 90% 91%
REPORTS
LCD Panel

Converter status – load level – input/output voltage – fault

ALARMS
Overload I play every second
Fault Continuous sound
Dimensions and weight
Dimensions DxWxH mm 410x438x88 410x438x88 510x438x88 630x438x88
Net weight kg. 7 7 11 13
ENVIRONMENTAL CONDITIONS
Operating Humidity 20 ÷ 90% RH @ 0 ÷ 40°C (non-condensing)
Noise < 50Dba @ 1 m.
INTERFACES
Smart RS232/USB Windows family, Linux, Mac
Optional SNMP Power management per SNMP manager e web browser

 

  ERT106K-FC ERT110K-FC
POWER 4.8KVA/4.8KW 8KVA/8KW
INPUT DATA
Tension Voltage rating 230Vac single-phase (or others on request)
Voltage range 110-300Vac ±5% at 50% load / 176-300Vac ±5% at 100% load
Low Line Return 170Vac ±5%
Return high line 290Vac ±5%
Frequency 46:54Hz @ 50Hz / 56:64Hz @ 60Hz
No. Of phases Single-phase with ground
PF Power Factor ≥ 0.99 to rated voltage (100% load)
OUTPUT DATA
Voltage 230Vac single-phase (or others on request)
Voltage tolerance (battery mode) ±1%
Frequency (synchronization range) 46Hz : 54Hz o 56Hz : 64 Hz
Output Frequency 50Hz ± 0.1Hz o 60Hz ± 0.1Hz
Crest Current Factor 3 : 1
Harmonic distortion ≤ 2% THD (linear load) ≤ 4% THD (nonlinear load)
Wave form SINE WAVE
EFFICIENCY
With network present

91%

REPORTS
LCD Panel Converter status – load level – input/output voltage – fault
ALARMS
Overload

Double sound every second

Fault

Continuous sound

Dimensions and weight
Dimensions DxWxH mm 610X438X88 610X438X88
Net weight kg. 17 20
ENVIRONMENTAL CONDITIONS
Operating Humidity 0 ÷ 95% RH @ 0 ÷ 40°C (non-condensing)
Noise < 58Dba @ 1 m. < 60Dba @ 1 m
INTERFACES
Smart RS232/USB Windows family, linux, Unix, Mac
Optional SNMP Power management per SNMP manager e web browser

 