EG1 – UPS TOWER ONLINE DOUBLE CONVERSION, SINE WAVE, 1 TO 10KVA
UPS TOWER ON-LINE DOUBLE CONVERSION, SINE WAVE, FROM 1 TO 10KVA
The EG1 series is available from 1 KVA to 10 KVA with On-Line double conversion technology with digital control. For its versatility, this range is suitable to supply any electrical and electronic system even in critical situations, in addition to the possibility of using it as a 50/60Hz frequency converter or in combination with motor current generators
FEATURES
- DOUBLE CONVERSION UPS
A true DOUBLE CONVERSION UPS that will provide a perfect current, for complete high-quality protection for your sensitive devices, such as PC networks (Networks), Small Data Centers, Servers, Telecommunications, Healthcare / Hospital Equipment, and in industrial applications in general
- OUTPUT POWER FACTOR φ 1.0
Comparing this line of ON-LINE UPS with the competition on the current market, we can say that the EG1 UPS have the best 1.0 output Power Factor. Deliver high throughput and efficiency for critical applications
- WIDE INPUT RANGE (110V-300V)
EG1 is able to provide stable and clean current to the connected equipment even in very critical and unstable environments.
- PROGRAMMABLE OUTPUT SOCKETS
With the programmable outlets output, the user can easily control part of the load connected to the UPS. During power outages, this function allows the user to increase the autonomy of the batteries and dedicate it to the exclusive protection of some critical appliances, interrupting the power supply to non-essential equipment
- FREQUENCY CONVERTER FUNCTION 50/60 Hz
Lock the output frequency to 50Hz or 60Hz regardless of the input frequency and eliminate the By-Pass
- FUNCTION (EPO) Emergency Power Off
This function is used to extinguish the UPS by the personnel in case of fire and other emergency situation.
- SIMULTANEOUS OPERATION OF SNMP+USB+RS-232
This feature allows you to use communication from all USB, RS-232 and SNMP ports simultaneously (optional SNMP card).
- BATTERY CHARGER DESIGNED TO OPTIMIZE BATTERY PERFORMANCE
. The EG101-03K series is equipped with a 2-step battery charger to ensure maximum autonomy. It also adjusts the charging voltage according to the working temperature. All these measures have been designed to extend the life of the batteries mounted in the UPS over time.
. The EG106-10K UPSs are equipped with an extendable 3-step battery charger to optimize battery performance. This feature prolongs the autonomy and optimizes the charging time of the battery, also the extension of the battery charger is essential for charging batteries with greater power used to obtain long autonomy
- MANUAL BY-PASS FOR MAINTENANCE ON UPS FROM 6K ONWARDS
The manual By-Pass ensures the absence of voltages inside the UPS for maintenance, ensuring power to the connected equipment.
- REDUNDANT PARALLEL OPERATION FOR UPS FROM 6 TO 10K (optional)
The EG106K and EG110K can work in redundant parallel up to 3 units, this increases power capacity, work safety without service interruptions.
COMMUNICATION
Software for all operating systems and network environments, SUPERVISION platform and shut-down UPSILON 2000
WARRANTY 24 MONTHS
| MODEL | EG101K (S) | EG101.5K (S) | EG102K (S) | EG103K (S) | |||
| POWER | 1000 VA / 1000 W | 1500 VA / 1500 W | 2000 VA / 2000 W | 3000 VA / 3000 W | |||
| INPUT | |||||||
| Volt Range | Nominal voltage | 200/208/220/230/240VAC | |||||
| Line switching
low / high |
110VAC / 300VAC ±3% @ 50% load
160VAC / 300VAC ±3% @ 100% load |
||||||
| Frequency range | 40 Hz ~ 70 Hz | ||||||
| Phases | single phase with Neutral | ||||||
| Power factor P. F. | ≧ 0.99 @ rated voltage (100% load) | ||||||
| OUTPUT | |||||||
| Nominal voltage | 200/208/220/230/240VAC | ||||||
| Volt tolerance (Batt. Mode) | ± 1% | ||||||
| Frequency (Synchronization Range) | 47Hz ~ 53 Hz or 57Hz ~ 63 Hz | ||||||
| Frequency (Range Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | ||||||
| Ridge Current Factor | 3:1 | ||||||
| Harmonic distortion | ≦ 2 % THD (linear load)
≦ 4 % THD (non-linear load) |
||||||
| Intervention time | Line to battery | Zero | |||||
| From Inverter to Bypass | 4 ms (typical) | ||||||
| Waveform (Batt. Mode) | PURE SINUSOIDAL | ||||||
| EFFICIENCY | |||||||
| With network present | ≧ 89% | ≧ 91% | |||||
| With battery operation | ≧ 88% | ≧ 90% | |||||
| BATTERIES | |||||||
| Standard model and long-life model with external autonomy | Battery Type | 12 V / 7 Ah | 12 V / 9 Ah | 12 V / 7 Ah | 12 V / 9 Ah | ||
| Battery quantity | 3 | 3 | 6 | 6 | |||
| Typical charging time | 3 hours at 90% capacity | ||||||
| Charging current (max.) | Default 2.0A max 12 A settable | Default 2.0A max 8 A settable | |||||
| Charging voltage | 41.0 VDC ± 1% | 82.1 VDC ±1% | |||||
| REPORTS | |||||||
| LCD panel |
UPS Status, Load Level, Battery Level, Input/Output Voltage, Battery Discharge Time, Fault Condition |
||||||
| ALARMS | |||||||
| Battery operation | Sound every 4 seconds | ||||||
| Low Battery | I play every second | ||||||
| Overload | Double sound every second | ||||||
| Fault | Continuous sound | ||||||
| DIMENSIONS AND WEIGHTS | |||||||
| Tower Format | Standard Model | Dimensions, D x W x H (mm) | 397 x 145 x 220 | 421 x 190 x 318 | |||
| Net weight (kg) | 13,00 | 14,60 | 23,20 | 28,00 | |||
| Model without batteries | Dimensions, D x W x H (mm) | 397 x 145 x 220 | 421 x 190 x 318 | ||||
| Net weight (kg) | 7 | 12,30 | |||||
| ENVIRONMENTAL DATA | |||||||
| Operating humidity | 20-90 % RH @ 0- 40°C (Non-condensing) | ||||||
| Noise | < 50dBA @ 1 M | ||||||
| INTERFACES | |||||||
| Smart RS-232/USB | Windows family, Linux and MAC | ||||||
| Optional SNMP | Power management for SNMP manager and web browser | ||||||
| * (S) Identify long-life models
* Product specifications may be subject to change without notice |
|||||||
| MODEL | EG106K (S) | EG1010K (S) | |
| PHASES | Single-phase input / single-phase output | ||
| POWER | 6000 VA / 6000 W | 10000 VA / 10000 W | |
| INPUT | |||
| Volt Range | Nominal voltage | 200/208/220/230/240VAC | |
| Low/high line switching | 110VAC / 300VAC ±3% @ 50% load
160VAC / 300VAC ±3% @ 100% load |
||
| Frequency Range | 46~54 Hz ◎ 50Hz / 56~64 Hz ◎ 60Hz | ||
| Phases | Single phase with Earth | ||
| Power factor P.F. | ≧ 0.99 @ 100% of the load | ||
| THDi % |
≦ 5% |
||
| OUTPUT | |||
| Nominal voltage | 200/208/220/230/240VAC | ||
| Volt tolerance (Batt. Mode) | ± 1% | ||
| Frequency (Synchronization Range) | 47~53 Hz ◎ 50 Hz / 57~63 Hz ◎ 60 Hz | ||
| Frequency (Range Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||
| Ridge Current Factor | 3:1 | ||
| Harmonic distortion | ≦ 2 % THD (linear load)
≦ 4 % THD (non-linear load) |
||
| Intervention time | Line to battery | Zero | |
| From Inverter to Bypass | Zero | ||
| Waveform (Batt. Mode) | PURE SINUSOIDAL | ||
| EFFICIENCY | |||
| With network present | 94% | ||
| With battery operation | 91% | ||
| BATTERIES | |||
| Standard model and mod. long autonomy with external batteries | Battery Type | 12 V / 7 AH | 12 V / 9 AH |
| Battery quantity | 20 | 20 | |
| Typical charging time | 7 hours 90% capacity | 9 hours 90% capacity | |
| Charging current (max.) | 1.0 A @ 4.0 A | ||
| Charging voltage | 273.0 VDC | ||
| REPORTS | |||
| LCD panel |
UPS Status, Load Level, Battery Level, Input/Output Voltage, Battery Discharge Time, Fault Condition |
||
| ALARMS | |||
| Battery operation | Sound every 4 seconds | ||
| Low Battery | I play every second | ||
| Overload | Double sound every second | ||
| Fault | Continuous sound | ||
| DIMENSIONS AND WEIGHTS | |||
| Standard Model | Dimensions, D x W x H (mm) | 592 x 250 x 576 | |
| Net weight (kg) | 81 | 83 | |
| Models (S)
Long autonomy |
Dimensions, D x W x H (mm) | 592 x 250 x 576 | |
| Net weight (kg) | 22 | 24 | |
| ENVIRONMENTAL DATA | |||
| Operating humidity | 20-90 % RH @ 0- 40°C (non-condensing) | ||
| Noise | < 55dBA @ 1 Metro | < 58dB @ 1 Metro | |
| INTERFACES | |||
| Smart RS-232 | Windows family, Novell, Linux and FreeBSD | ||
| USB | |||
| Optional SNMP | Power management for SNMP manager and web browser | ||
| * (S) Identify long-life models
* product specifications may be subject to change without notice |
|||