ATT-GN – THREE PHASE AUTOTRASFORMERS – NEUTRAL GENERATORS from 3 to 200kVA

THREE PHASE AUTOTRASFORMERS – NEUTRAL GENERATORS from 3 to 200kVAthree phase autotransformer for generating neutral

Different power grids in Italy and in the world do not have the Neutral; in the presence of single-phase loads or unbalanced loads it is necessary to generate a stable Neutral. When it is not necessary to separate the loads from the network with a Dyn11 isolating transformer you can use an auto-generator Neutral, incorrectly called an autotransformer as from the construction point of view it is a reactor connected to ZigZag. When you must also adapt the mains voltage (eg. From 220V to 400V) you can use a real step-up/down autotransformer with simple or double ZigZag connection. schema trasformatore isolamento sicurezza schermo
sim-trafoaut
sim-ce
 disegno autotrasformatori trifase generatori di neutro morsettiere  disegno autotrasformatori trifase generatori di neutro bulloni
A B
Part no. Rated power Rated voltage

V

Dimensions

mm.

weight

KG.

ATTGN249 3 400+N 240X120X205 12
ATTGN287 5 400+N 240X130X205 15
ATTGN387 10 400+N 300X130X255 24
ATTGN403 12 400+N 300X140X255 29
ATTGN427 15 400+N 300X150X255 33
ATTGN467 20 400+N 360X160X305 42
ATTGN483 22 400+N 360X160X305 44
ATTGN507 25 400+N 360X170X305 49
ATTGN547 30 400+N 360X180X305 55
ATTGN627 40 400+N 420X190X355 73
ATTGN707 50 400+N 420X200X355 85
ATTGN727 60 400+N 420X210X355 98
ATTGN747 70 400+N 420X240X355 108
ATTGN767 80 400+N 480X234X405 117
ATTGN787 90 400+N 480X244X405 129
ATTGN807 100 400+N 480X254X405 142
ATTGN811 120 400+N 480X274X405 163
ATTGN817 150 400+N 600X270X505 201
ATTGN822 175 400+N 600X290X505 240
ATTGN827 200 400+N 600X320X505 285
schema autotrasformatore generatore di neutro schema autotrasformatore generatore di neutro con presa intermedia
neutral generator step up / down neutral generator

An important application in low voltage application of the zig-zag reactors should be reported, grown in importance with the spread of non-linear loads that draw current not of sinusoidal form, containing, therefore, as to say, a high harmonic content. Such loads (rectifiers, inverters etc.) may be regarded as current generators of harmonics that cause of deforming the voltage drops on the network impedances. The phenomenon is all the more sensitive as far as the power of the distorting load is close to that of the transformer and can become absolutely intolerable when the generator is not the public network but a generator. It is therefore necessary to make sure that the impedances “found” by these currents are as small as possible. The third-harmonic currents, that is, of triple the fundamental frequency and its multiples are in a three-phase system, homopolar backhoe concerned and the impedance is that the zero sequence. The reactors in a zig-zag have, as mentioned, the zero sequence impedances that can be very low for which prevent or at least attenuate the onset of the corresponding voltage harmonics. They work so as compensating harmonics for non-linear loads. They must be installed in the immediate vicinity of the distorting load.

schema collegamento autotrasformatore generatore di neutro
schema collegamento autotrasformatore generatore di neutro