PSS – THREE-PHASE CENTRALIZED EMERGENCY POWER SUPPLIES TO EN50171 FROM 10KVA TO 200KVA

THREE-PHASE CENTRALIZED EMERGENCY POWER SUPPLIES TO EN50171 FROM 10KVA TO 200KVA

The PSS series is a high-frequency double-conversion online type, with three-phase input and output, available in sizes from 10kVA to 200kVA.

High efficiency and efficiency at PF 0.9 and PF 1.

The PLA series leverages modularized power technology and uses N+X redundancy. The number of UPS modules can be flexibly varied according to the load to be connected, which makes the investment gradual and cost-effective.

It can solve any power supply problems, such as blackouts, surges, undervoltage, sudden voltage drop, voltage spikes, voltage fluctuation, overcurrent, current spikes, Total Harmonic Distortion (THD), interference noises, frequency oscillation, etc.

This series is controlled by a Digital Signal Processor (DSP), which increases and increases reliability, performance, self-protection and self-diagnosis.

It is a high-intensity RESCUER system whose input current is kept balanced. Acceptable load unbalance up to 100%.

KEY FEATURES

  • On-line double conversion UPS with three-phase input + N, three-phase output + N
  • 0ms switching time
  • Power factor 0,9 e 1
  • LCD panel with display of all the main parameters
  • Modularized power from 10KVA to 200KVA
  • Full control with DSP (Digital Signal Processor)
  • Low input distortion > 2%
  • Prepared for communication with SNMP, MODBUS, RELAY, USB card, RS485
  • EPO contact as standard
  • Battery configurable with dynamic from 16 -18 – 20 monoblocs according to your needs
  • ModBus 485
  • Parallel to the same point on the distribution board.

Electrical cables that include bypass input cables and UPS output cables must be of the same length and specifications. This makes it easier to distribute the load when operating in bypass mode.

MODEL PSS010 PSS015 PSS020 PSS030 PSS040 PSS060
Input Power (KVA/KW) 10 / 10 15 / 15 20 / 20 30 / 30 40 /40 60 /60
according to EN50171 (KW) 7.5 11.3 15 22.5 30 45
No. of phases 3 Steps 4 Cables and Grounding
Rated voltage 380/400/415Vac
Voltage Range 208~478Vac
Frequency Range 45-55Hz to 50Hz / 56-66Hz to 60Hz (auto detection)
Power factor ≥0.99
THDi Current ≤2% (100% nonlinear load)
Bypass voltage range Max. voltage:                      220Vac:+25% (optional +5%,+10%,+15%)
230Vac:+20% (optional +10%,+15%)
240Vac:+15% (optional +10%)
Min. Voltage:                      -45% (optional -20%, -30%)
Frequency Protection Range: ±10%
Generator Set Input Supported
Output Stages 3 Steps 4 Cables and Grounding
Rated voltage 380/400/415Vac
Power factor 0.9
Voltage regulation ±1%
Frequency With mesh ±1%, ±2%, ±4%, ±5%, ±10% of rated frequency (optional)
In battery mode (50/60±0.1%) Hz
Crest factor 3:1
THD ≤1% with linear load
≤3% with nonlinear load
Efficiency (in normal mode) ≥96.5% ≥97.5%
Battery Tension UPS standard: ±120Vdc (10+10)  12V 7/9AH

Long autonomy UPS ±96V/±108V/±120Vdc (16/18/20 pcs. Optional)

UPS standard: ±240Vdc (20+20)

12V 7/9AH

Long Range UPS: ±192/±204/±216/±228/±240Vdc (32/34/36/38/40

pcs optional)

UPS standard: ±120Vdc (10+10)  12V 7/9AH

Long autonomy UPS ±96V/±108V/±120Vdc (16/18/20 pcs. Optional)

Charging Current(A) The charging current is automatically set according to the capacity, quantity and dynamics of the batteries inserted

UPS standard (20pcs): 1.35A

UPS standard (2X20pcs): 2.7A

UPS standard (3X20pcs): 4.5A

Long Range UPS: Max 10A

Type VRLA with 10-year expected lifespan
Remaining battery life 60 / 90 /120 minutes
Charging capacity 80% in 12h
Battery Tests Set by Default to run the test every 30 days
Transfer Time Intervention time according to EN50171 regulations

download the pdf catalogue for the full datasheet of all the powers of the PSS range.