SC1 – PURE SINE WAVE CENTRALIZED EMERGENCY POWER SUPPLY CPSS EN50171 1-10KVA SINGLE-PHASE AND THREE-PHASE

The SC1 series is available in ratings from 1 kVA to 20 KVA; with its technology and its versatility is suitable to supply any electrical system 

  • Safety lighting;
  • Electrical circuits of automatic fire-fighting systems;
  • Pager systems and safety signaling system;
  • Fume extraction equipment;
  • Signalling systems for the presence of carbon monoxide;
  • Specific safety systems for particular buildings, for example, in high-risk areas.

Features

  • Double Conversion Emergency power supply: a double conversion continuity system that will provide perfect voltage for complete high-quality protection for your sensitive devices
  • Output power factor φ 0.8 (0.9 for single-phase models up to 10kVA): Comparing this line to power supplies in the current market competition, we can state that SCO’s have the best Power Factor output 0.8 (0.9 for single-phase models up to 10kVA). They offer high performance and great efficiency for critical applications
  • Large input RANGE (110 V-300 V): SCO is able to supply stable and clean current to the connected equipment even in very critical and unstable environments.
  • Emergency Power Off (EPO) function: this function is used to shut off the power supply by the personnel in case of fire and other emergency situations.
  • Simultaneous operation of SNMP + USB + RS-232: this feature allows you to use communication from all USB, RS-232 and SNMP ports simultaneously.
  • Battery charger designed to optimize battery PERFORMANCE: The SCO 1-3k series is equipped with a 2-step battery charger to ensure maximum autonomy. It also adjusts the charging voltage according to the working temperature. All these measures have been designed to prolong the life of the batteries mounted in the SCO over time. The SCO 6-20K are equipped with an extensible 3-step battery charger to optimize battery performance. This feature extends the autonomy and optimizes the charging time of the battery, also the extension of the charger is essential for charging higher power batteries used to get long autonomy
  • Manual BY-PASS for maintenance: the manual bypass ensures the lack of voltages inside the SCO during maintenance operations, ensuring power to the connected equipment.
  • Power Factor Correction on all stages for TRI/SINGLE phase 10KVA to 20KVA: PFC improves the quality of the absorbed current and increases the energy efficiency, with the consequent economic savings

Communication

Software for all operating systems and network environments, supervision platform and shutdown ViewPower/ViewPowerPro

Main Features SCO EN 50171

  • Continuous overload of 120%
  • Polarity inversion protection
  • High charging current
  • Casing with high mechanical protection
  • 10 years battery life
  • Autonomy restore to 80% within 12 hours after deep discharge

SC1 1k/2k/3k Single-phase ONLINE double Conversion

Model SC101K SC102K SC103K
Rated Power 1000 VA / 1000 W 2.000 VA / 2.000 W 3.000 VA / 3.000 W
Power to EN 50171 833 VA / 833 W 1.666 VA / 1.666 W 2.500 VA / 2.500 W
INPUT
Voltage Ranges Low line switching 160 VAC/140 VAC/120 VAC/110 VAC ± 5%

(Network Base in percentage   100%-80%/80%-70%/70-60%/60%-0)

Low line return 175 VAC ± 5
High Line switching 300 VAC ± 5%
High return line 290 VAC ± 5%
Frequency Range 40 Hz ~ 70 Hz
No. of phases Single Phase with neutral
Power factor P. F. ≧ 0.95
OUTPUT
Voltage tolerance (Batt. Mode) ± 3%
Frequency (Sync Range) 47.5 Hz ~ 52.5 Hz or 57Hz ~ 63 Hz
Frequency (Range Batt. Mode) 50 Hz ± 0.25 Hz or 60hz ± 0.3 Hz
Crest Factor 3:1
Harmonic distortion ≦ 3% THD (linear load)

≦ 6% THD (non-linear load)

≦ 4% THD (linear load)

≦ 7% THD (non-linear load)

Intervention time From line to battery Zero
from inverter to Bypass 4 MS (typical)
Waveform (Battery Mode) Pure sine wave
EFFICIENCY
With network present ≥ 89% ≥ 91%
battery operation ≥ 88% ≥ 90%
BATTERY
Battery type See tables
Battery quantity See Tables
Typical autonomy See table See table See table
Charging current (max.) Default 2.0 A max 12 A settable
Charging voltage 41.0 VDC ± 1% 82.1 VDC ± 1%
SIGNALS
LCD Panel Power supply status, load level, battery level, input/output voltage, battery discharge time, fault condition
ALARMS
Battery operation Sound every 4 seconds
Low battery Sound every second
Overload Double sound every second
Failure Continuous sound
SIZE AND WEIGHT
Tower format Dimensions, P x W x H (mm) 397 x 145 x 220 421 x 190 x 318
Net weight (kg) 6.86 12.93
ENVIRONMENTAL DATA
Operating Humidity 20-90% RH @ 0-40 °c (non-condensing)
Noise < 45dBA @ 1 meter
INTERFACES
Smart RS-232/USB Windows family, Linux, Unix, Mac
Optional SNMP Power Management for SNMP manager and web browser
* Product specifications may be subject to change without notice

 

SC1 6K/10k Single-phase ONLINE Double Conversion

Model SC106K SC110K
Rated Power 6.000 VA / 6.000 W 10.000 VA / 10.000 W
Power to EN 50171 5.000 VA / 5.000 W 8.330 VA / 8.330 W
INPUT
Voltage Ranges Low line switching  176 VAC @ 100% load

110 VAC @ 50% load

Low line return  186 VAC @ 100% load

120 VAC @ 50% load

High Line switching  300 VAC
High return line  290 VAC
Frequency Range 46 ~ 54 Hz ◎ 50hz/56 ~ 64 Hz ◎ 60hz
No of phases Single Phase with Earth
P.F. Power factor ≧ 0.99 @ 100% of load
OUTPUT
Voltage tolerance (battery Mode) ± 1%
Frequency (Sync Range) 46 ~ 54 Hz ◎ 50 Hz/56 ~ 64 Hz ◎ 60 Hz
Frequency (Range battery Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1
Harmonic distortion ≦ 2% THD (linear load)-  ≦ 6% THD (non-linear load)
Intervention time From line to battery Zero
from inverter to Bypass Zero
Waveform (Battery Mode) Pure sine wave
EFFICIENCY
With network present 94%
With battery operation 91%
BATTERY
Battery type 12v/9AH 12v/9AH
Battery quantity See table See table
Charging current (max.) Default 1.0 A max 4 A settable
Charging voltage 273.0 VDC
REPORTS
LCD Panel

Power supply status, load level, battery level, input/output voltage, battery discharge time, fault condition

ALARMS
Battery operation Sound every 4 seconds
Low battery Sound every second
Overload Double sound every second
Failure Continuous sound
SIZE AND WEIGHT
Tower format Dimensions, P x W x H (mm) 592 x 250 x 576
Net weight (kg) 22 24
ENVIRONMENTAL DATA
Operating Humidity 20-90% RH @ 0-40 °c (non-condensing)
Noise < 45dBA @ 1 meter < 58dB @ 1 meter
INTERFACES
Smart RS-232

Windows family, Linux Unix and Mac

Usb
Optional SNMP

Power Management for SNMP manager and web browser

* Product specifications may be subject to change without notice

 

WhatsApp
Invia con WhatsApp
GDPR Cookie Consent with Real Cookie Banner