home page

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ISP

10-50VA

ITA

50-3000VA

EUR

multitap 50-3000VA

ET

multitap 50-3000VA

TOR

toroidal 20VA-10kVA

MC

4-20kVA

isolation and safety

TE

50-3000VA

ALI

 50-1000VA LIGHTING 12V

TMIB

 for medical dev. 0.3:2kVA

TMI

 3000-25000VA

TMI64

 medical use 3000-25000VA

ALX

 ip55 class II 200-500VA

three phase transformers

power

TTP

 1-500kVA

isolation and safety

TTI

1-40kVA

TTI-K

k-factor transf. 15-300kVA

autotransfomers

SB

 110/220 revers. 0.1-10kVA

ATM

 single phase 0,1-5kVA

KVA

 three phase 1-500kVA

ATTP

 three phase 1-300kVA

ATTP1

three phase +box 1-300kVA

ATV

motor starting  7-220kW

metal enclosures

metal enclosures

voltage stabilisers

AVR

voltage regulators

SEN

 electronic 1 phase 0.5-2KVA

IMP1

 electronic 1 phase 3-30KVA

R

1ph. servo rack 2-10kVA

RB

1ph. servo motor 2-10kVA

R25

1ph. servo 3-22kVA

RAF

line conditioners HI-FI 1.5-3k

IMP3

 electronic 3 phase
10-2000KVA

RTC

3phase electrom. 6-30kVA

RTC220

3phase electrom. 220V

RTI

three ph.line conditioners

RTG

3phase electrom. to 500kVA

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

frequency converters

GMM

1, 3>1ph. 50/60Hz frequency converter from 3 to 15kVA

GTT

3ph. 50/60Hz frequency converter from 9 to 100kVA

GSC

1ph. 50/60Hz frequency converter 6-9A

GSC

1, 3>1ph. 50/60Hz frequency converter from 20 to 65A

other products

VAR-N

single phase variable autotransformers

VAR-3N

three phase variable autotransformers

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2013 by:

web factory

 

   

HOSPITAL EARTH LEAKAGE CONTROL SYSTEM ISO-64 range

AUX VOLT. FREQUENCY TOT. MEASURING V. TOT. EMASURING A.
220V a.c. ±20% 50 : 60 Hz < 15V < 0,6 mA

New earth leakage control system suitable for use in medical environment. It applies a continuous voltage between the secondary of the isolation transformer and the earthing point of the system; in case of an earth fault, it mesures the current and consequently the islation resistance of the circuit. ISO64 is the most complete system for the control of IT systems in medical environment. Further to the standard control of the earth leakage required by EN61558-2-15 standard, also controls rhe impedance of the circuit or, first in the market, checks the proper connection of the relay to the system. ISO-64 systems automaticcally checks the connections of the relay reference to the central tap of the secondary transformer and to the earthing (PE) point. If any of these connections is interrupted, the ALARM LED on the front panel immediately flashes. This signal is really essential, as the lack of these connection may result in a bad performance of the system. ISO64 con be combined with the ISO-64R Remote controls to be installed in 503 switch box, and carry a test and sound off botton, mains light, fault light and buzzer.The max number of remote controls connected to each control system is 4. The single phase isolation transformers TMI64 and three phase isolatin transformers TTI64 are compatible with the system.

 MODEL

ISO-64

 Aux. voltage 220V ± 20%
 frequency 50 : 60 Hz
 max consumption 3VA
 total measuring current <0,6mA
 resistive leakage measuing current 0,012 mA
 capacitive leakage measuring current 0,3mA
 internal impedance for resistive measure 1 Mohm
 internal impedance for resistive and capacitive measure < 600 Kohm
 led steps 5000-1000-500-250-50-25 Kohm
 ouutput: 1 Nc-No Relay 5A 250V
 output for remote control Pr1 type MAX 4
 signal circuit voltage < 24V c.c.
 isolation test 2,5kV 60 sec.
 temperature -10°C : +60°C
 warehouse temperature -20°C : +80°C
 relative humidity 90%
 applied standards CEI 64-4-1438 / 64-8-1000
 DIN50022 mounting fast mounting clip on 35MM rail
 dimensions 6 DIN modules 17,5mm.
 