home page

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ISP

10-50VA

ITA

50-3000VA

EUR

multitap 50-3000VA

ET

multitap 50-3000VA

TOR

toroidal 20VA-10kVA

MC

4-20kVA

isolation and safety

TE

50-3000VA

ALI

 50-1000VA LIGHTING 12V

TMIB

 for medical dev. 0.3:2kVA

TMI

 3000-25000VA

TMI64

 medical use 3000-25000VA

ALX

 ip55 class II 200-500VA

three phase transformers

power

TTP

 1-500kVA

isolation and safety

TTI

1-40kVA

TTI-K

k-factor transf. 15-300kVA

autotransfomers

SB

 110/220 revers. 0.1-10kVA

ATM

 single phase 0,1-5kVA

KVA

 three phase 1-500kVA

ATTP

 three phase 1-300kVA

ATTP1

three phase +box 1-300kVA

ATV

motor starting  7-220kW

metal enclosures

metal enclosures

voltage stabilisers

AVR

voltage regulators

SEN

 electronic 1 phase 0.5-2KVA

IMP1

 electronic 1 phase 3-30KVA

R

1ph. servo rack 2-10kVA

RB

1ph. servo motor 2-10kVA

R25

1ph. servo 3-22kVA

RAF

line conditioners HI-FI 1.5-3k

IMP3

 electronic 3 phase
10-2000KVA

RTC

3phase electrom. 6-30kVA

RTC220

3phase electrom. 220V

RTI

three ph.line conditioners

RTG

3phase electrom. to 500kVA

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

frequency converters

GMM

1, 3>1ph. 50/60Hz frequency converter from 3 to 15kVA

GTT

3ph. 50/60Hz frequency converter from 9 to 100kVA

GSC

1ph. 50/60Hz frequency converter 6-9A

GSC

1, 3>1ph. 50/60Hz frequency converter from 20 to 65A

other products

VAR-N

single phase variable autotransformers

VAR-3N

three phase variable autotransformers

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2013 by:

web factory

SINGLE PHASE ISOLATION TRANSFORMERS
FOR MEDICAL EQUIPMENTS POWER SUPPLY

POWER INPUT OUTPUT FREQUENCY STANDARDS
FROM 300 TO 2000VA 230V 230V 50/60 Hz EN 61558-2-6
EN60601-1

single phase transformers for medical use

single phase transformers for medical use

The TMIB isolation transformers have been designed to obtain the highest isolation from the electric network for the supply of medical devices, WITH AN EARTHED SCREEN between primary and secondary winding. They are fitted with a 10A green led 2 poles circuit breaker on the front, while on the back side are placed all connectors, input IEC with 2 fuses, 8 output IEC sockets to EN60320-2 rated 10A each, output fuse protection. A proper connection cable is supplied.  Metal case IP21, painted RAL7032 with lifting handle. Higher ratings available on request.

  • installed in IP21 metal enclosure

  • ral7032 epoxy painted

  • lifting handles

  • 2-poles illuminated 10A rocker switch on front (automtic circuit breaker above 1.5kVA)

  • input plug to EN60320-1 with 2-poles input fuse

  • 2 time delay fuses according to the rating

  • thermal resettable protection against short circuit, in series with primary winding

  • isolation transformer with earthed copper screen

  • 8 output sockets to EN60320-2 each max 10A (max current limited to max power of the unit)

  • extra auxiliary equipotential earth male connector

  • Output fuse according to rating

  • Rating plate, operating manual, CE certificate

  • 3000-4000VA models have terminal blocks on input and output side, cables are to be provided at the place of the installation accoriding to the requirements of the standards

single phase isolation transformer for use with medical equipment

single phase isolation transformer for use with medical equipment

300VA model

rear connectors 300VA

single phase isolation transformer for use with medical equipment

single phase isolation transformer for use with medical equipment

1500-2000VA model

rear connectors 1500-2000VA

 POWER:  from 0.3 to 2KVA

 Input voltage:

 230V
 Output voltage:  230V
 Frequency  50/60Hz
 Protection of the transformer (without enclosure)  IP00
 Protection class  I
 Isolation class:  F
 Isolation class of the winding  F-H
 Ambient temperature  25°C
 Ma temperature rise  80°C
 Max regulation at full load  3.5%
 Short circuit current  5% max
 Efficiency  >97%
 Cooling  AN
 Max relative humidity  95%
 Altitude  up to 1000m.above sea level without derating
 Applied standards  EN61558-2-4 (CEI 96-8)
 EN60601-1-1 (CEI 62-51)
 Dimensions (mm.)

 300VA : 170x230xh.80
 500-1000VA: 180X280xh.165
 1500-2000VA: 180X350Xh.190

SEE THE PDF PAGE OF THE CATALOGUE

HOME PAGE  -  VERSIONE ITALIANA  -  CREDITS  -  COPYRIGHT - E-MAIL

Data shown no this page are for reference only and can be changed withouth further notice