Skip to content

ERT1 – 19″ RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1 TO 10KVA

ON LINE UNINTERRUPTIBLE POWER SUPPLIES ERT1 Pure sine wave, double conversion CONVERTIBLE RACK-TOWER

The ERT1 CONVERTIBLE RACK series is available in ratings from 1 KVA to 10 KVA with digitally controlled double conversion On-Line technology. Thanks to its versatility, this series is suitable for supplying any electrical and electronic system even in critical situations, as well as the possibility of using it as a 50 / 60Hz frequency converter or in combination with motor current generators.

 

MAIN FEATURES

 

  • DOUBLE CONVERSION UPS

A true DOUBLE CONVERSION UPS that will provide perfect current, for complete high-quality protection for your sensitive devices, such as PC networks (Networks), Small Computing Centres, Servers, Telecommunications, Health / Hospital Appliances, and in industrial applications in general.

  • OUTPUT POWER FACTOR φ 1.0

Comparing this ON-LINE UPS line with the competition on the market, we can say that ERT1 UPS have the best output Power Factor 1.0. They offer high performance and efficiency for critical applications.

  • WIDE INPUT RANGE (110 V -300 V)

ERT1 is capable of providing stable and clean current to connected equipment even in very critical and unstable environments.

  • HOT BATTERY REPLACEMENT (MODELS 1:3KVA)

ERT1 is able to provide stable and clean current to connected equipment even during battery replacement.

  • PROGRAMMABLE OUTLETS

With the programmable output sockets, the user can easily control part of the load connected to the UPS. During power outages, this function allows the user to increase the autonomy of the batteries and dedicate it to the exclusive protection of some critical devices, by interrupting the power supply to non-essential equipment.

Programmable outlets (P1)

connect non-essential appliances.

  • FREQUENCY CONVERTER FUNCTIONS 50/60 Hz

It sets the output frequency at 50Hz or 60Hz regardless of the input frequency and eliminates the By-Pass.

  • (EPO) Emergency Power Off

This function is used to shut down the UPS by the staff in the event of a fire and other emergency situations.

  • CONTEMPORARY USE OF SNMP+USB+RS-232

This function allows you to use communication from all USB, RS-232 and SNMP ports simultaneously (optional SNMP card).

  • BATTERY CHARGER TO OPTIMIZE THE BATTERY PERFORMANCE

. The ERT1 01-03K series is equipped with a 2-step battery charger to ensure maximum autonomy. It also regulates the charging voltage according to the working temperature. All these measures have been designed to extend the life of the batteries installed in the UPS over time.

. The ERT1 06-10K UPS are equipped with an extendable 3-step battery charger, to optimize battery performance. This feature prolongs the autonomy and optimizes the battery recharging time, furthermore the extension of the battery charger is essential for recharging batteries with higher power used to obtain long autonomy.

  • MANUAL BY-PASS FOR THE MAINTENANCE OF UPS FROM 6KVA

The manual By-Pass ensures the lack of voltage inside the UPS for maintenance, ensuring power to the connected equipment.

  • PARALLEL REDUNDANTE FUNCTION FOR UPS FROM 6 TO 10KVA

ERT106K and ERT110K can work in redundant parallel up to 3 units, this increases the power capacity, working safety without service interruption.

  • RACK 19” / TOWER design

The ERT1 series is called “convertible”, that is, it can be installed in RACK 19 “or TOWER version, with the easy rotation of the LCD display, making it the ideal system for the” backup power protection solution “for servers, rescue systems, network equipment and other types of loads.

The sliding guide accessory is available for assembling and extracting drawers in 19” rack cabinets.

  • Power Factor Correction up to 0.99

The PFC improves the quality of the absorbed current and increases the energy efficiency, with the consequent economic savings

  • Communication

Software for all operating systems and network environments. VIEWPOWER supervision and shutdown platform

24 MONTHS GUARANTEE

MODEL ERT101K ERT101.5K ERT102K ERT103K
POWER 1000VA/1000W 1500VA/1500W 2000VA/2000W 3000VA/3000W
INPUT DATA
Voltage Rated voltage 200/208/220/230/240Vac single phase
Voltage range 110-300Vac ±5% a 50% load

160-300Vac ±5% a 100% load

Low voltage threshold 170Vac ±5%
High voltage threshold 290Vac ±5%
Frequency range 40Hz : 70Hz ±5%
Number of phases Single phase with neutral
PF Power factor ≥ 0.99 at rated voltage (100% load)
Harmonic Distortion THDi% ≥ 5% @ rated voltage
OUTPUT DATA
Voltage 200/208/220/230/240Vac single phase
Voltage tolerance (battery mode) ±1%
Frequency (syncronisation range) 47Hz : 53Hz or 57Hz : 63 Hz
Frequency (battery mode range) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Crest Factor 3 : 1
Harmonic distortion ≤ 2% THD (linear load) ≤ 4% THD (non linear load)
Transfer time Line to battery Zero
In verter to by-pass 4 ms (typical)
Wave form (battery mode) PURE SINE WAVE
EFFICIENCY
With line voltage 89% 91%
Battery ≈ 88 ÷ 90%
BATTERIES
Standard model Battery type 12V / 9 Ah 12V / 9 Ah 12V / 9 Ah 12V / 9 Ah
No. Of batteries 2 3 4 6
Typical charging time 4 h for 90% capacity
Charging current (max) 2 A @ 12 A settable 2 A @ 8 A settable
Charging voltage 27.4Vdc ±1% 41.1Vdc ±1% 54.8Vdc ±1% 82.1Vdc ±1%
SIGNALS
LCD Panel

UPS state – Load level – battery level – input/output voltage – battery discharge time – fault

ALARMS
Battery operated Beep every 5”
Low battery Beep every 2”
Overload Beep every 1”
Fault Continuous beep
Dimensions and weight
Standard model Dimensions DxWxH mm 410x438x88 410x438x88 510x438x88 630x438x88
Net weight kg. 12 15 20 28
Model without battery Dimensions DxWxH mm 410x438x88 410x438x88 510x438x88 510x438x88
Net weight kg. 7 8 10 13
ENVIRONMENTAL CONDITIONS
Humidity 20 ÷ 90% RH @ 0 ÷ 40°C (without condensation)
Noise < 50Dba @ 1 m.
INTERFACES
Smart RS232/USB Windows family, linux, Unix, Mac
Optional SNMP Power management for SNMP manager and web browser

 

MODEL ERT106K ERT110K
POWER 6KVA/6KW 10KVA/10KW
INPUT DATA
Voltage Rated voltage 200/208/220/230/240Vac single phase
Voltage range 110-300Vac ±5% a 50% load

176-300Vac ±5% a 100% load

Low voltage threshold 170Vac ±5%
High voltage threshold 290Vac ±5%
Frequency range 46:54Hz @ 50Hz / 56:64Hz @ 60Hz
Number of phases Single phase with earth
PF Power factor ≥ 0.99 at rated voltage (load 100%)
Harmonic Distortion THDi% < 4% @ 100% del carico, < 6% @ 50% load
OUTPUT DATA
Voltage 200/208/220/230/240Vac single phase
Voltage tolerance (battery mode) ±1%
Frequency (syncronisation range) 46Hz : 54Hz or 56Hz : 64 Hz
Frequency (battery mode range) 50Hz ± 0.1Hz or 60Hz ± 0.1Hz
Crest Factor 3 : 1
Harmonic distortion ≤ 2% THD (linear load) ≤ 4% THD (non linear load)
Transfer time Line to battery Zero
Inverter to by-pass Zero
Wave form (battery mode) PURE SINE WAVE
EFFICIENCY
With line voltage 94%
Battery 92%
BATTERIES
Standard model Battery type 12V / 7.2 Ah 12V / 9 Ah
No. Of batteries 20 20
Typical charging time 7 h at 90% capacity 9 h at 90% capacity
Charging current (max) 1.0 A @ 4.0 A
Charging voltage 273.0Vdc
SIGNALS
LCD Panel

UPS state – Load level – battery level – input/output voltage – battery discharge time – fault

ALARMS
Battery operated Beep every 5”
Low battery Beep every 2”
Overload Beep every 1”
Fault Continuous beep
Dimensions and weight
Standard model Dimensions DxWxH mm UPS 610X438X88 (2U)+ batt. 600x438x133 (3U) UPS 610X438X88 (2U)+ batt. 600x438x133 (3U)
Net weight kg. 17+57 20+63
Model without battery Dimensions DxWxH mm 610x438x88 (2U) 668x438x88 (2U)
Net weight kg. 17 20
ENVIRONMENTAL CONDITIONS
Humidity 0 ÷ 95% RH @ 0 ÷ 40°C (without condensation)
Noise < 58Dba @ 1 m. < 60Dba @ 1 m.
INTERFACES
Smart RS232/USB Windows family, linux, Unix, Mac
Optional SNMP Power management for SNMP manager and web browser
WhatsApp