ERT1 – 19″ RACK UPS ONLINE DOUBLE CONVERSION, SINE WAVE, 1 TO 10KVA
ON LINE UNINTERRUPTIBLE POWER SUPPLIES ERT1 Pure sine wave, double conversion CONVERTIBLE RACK-TOWER
The ERT1 CONVERTIBLE RACK series is available in ratings from 1 KVA to 10 KVA with digitally controlled double conversion On-Line technology. Thanks to its versatility, this series is suitable for supplying any electrical and electronic system even in critical situations, as well as the possibility of using it as a 50 / 60Hz frequency converter or in combination with motor current generators.
MAIN FEATURES
- DOUBLE CONVERSION UPS
A true DOUBLE CONVERSION UPS that will provide perfect current, for complete high-quality protection for your sensitive devices, such as PC networks (Networks), Small Computing Centres, Servers, Telecommunications, Health / Hospital Appliances, and in industrial applications in general.
- OUTPUT POWER FACTOR φ 1.0
Comparing this ON-LINE UPS line with the competition on the market, we can say that ERT1 UPS have the best output Power Factor 1.0. They offer high performance and efficiency for critical applications.
- WIDE INPUT RANGE (110 V -300 V)
ERT1 is capable of providing stable and clean current to connected equipment even in very critical and unstable environments.
- HOT BATTERY REPLACEMENT (MODELS 1:3KVA)
ERT1 is able to provide stable and clean current to connected equipment even during battery replacement.
- PROGRAMMABLE OUTLETS
With the programmable output sockets, the user can easily control part of the load connected to the UPS. During power outages, this function allows the user to increase the autonomy of the batteries and dedicate it to the exclusive protection of some critical devices, by interrupting the power supply to non-essential equipment.
Programmable outlets (P1)
connect non-essential appliances.
- FREQUENCY CONVERTER FUNCTIONS 50/60 Hz
It sets the output frequency at 50Hz or 60Hz regardless of the input frequency and eliminates the By-Pass.
- (EPO) Emergency Power Off
This function is used to shut down the UPS by the staff in the event of a fire and other emergency situations.
- CONTEMPORARY USE OF SNMP+USB+RS-232
This function allows you to use communication from all USB, RS-232 and SNMP ports simultaneously (optional SNMP card).
- BATTERY CHARGER TO OPTIMIZE THE BATTERY PERFORMANCE
. The ERT1 01-03K series is equipped with a 2-step battery charger to ensure maximum autonomy. It also regulates the charging voltage according to the working temperature. All these measures have been designed to extend the life of the batteries installed in the UPS over time.
. The ERT1 06-10K UPS are equipped with an extendable 3-step battery charger, to optimize battery performance. This feature prolongs the autonomy and optimizes the battery recharging time, furthermore the extension of the battery charger is essential for recharging batteries with higher power used to obtain long autonomy.
- MANUAL BY-PASS FOR THE MAINTENANCE OF UPS FROM 6KVA
The manual By-Pass ensures the lack of voltage inside the UPS for maintenance, ensuring power to the connected equipment.
- PARALLEL REDUNDANTE FUNCTION FOR UPS FROM 6 TO 10KVA
ERT106K and ERT110K can work in redundant parallel up to 3 units, this increases the power capacity, working safety without service interruption.
- RACK 19” / TOWER design
The ERT1 series is called “convertible”, that is, it can be installed in RACK 19 “or TOWER version, with the easy rotation of the LCD display, making it the ideal system for the” backup power protection solution “for servers, rescue systems, network equipment and other types of loads.
The sliding guide accessory is available for assembling and extracting drawers in 19” rack cabinets.
- Power Factor Correction up to 0.99
The PFC improves the quality of the absorbed current and increases the energy efficiency, with the consequent economic savings
- Communication
Software for all operating systems and network environments. VIEWPOWER supervision and shutdown platform
24 MONTHS GUARANTEE
| MODEL | ERT101K | ERT101.5K | ERT102K | ERT103K | |||||
| POWER | 1000VA/1000W | 1500VA/1500W | 2000VA/2000W | 3000VA/3000W | |||||
| INPUT DATA | |||||||||
| Voltage | Rated voltage | 200/208/220/230/240Vac single phase | |||||||
| Voltage range | 110-300Vac ±5% a 50% load
160-300Vac ±5% a 100% load |
||||||||
| Low voltage threshold | 170Vac ±5% | ||||||||
| High voltage threshold | 290Vac ±5% | ||||||||
| Frequency range | 40Hz : 70Hz ±5% | ||||||||
| Number of phases | Single phase with neutral | ||||||||
| PF Power factor | ≥ 0.99 at rated voltage (100% load) | ||||||||
| Harmonic Distortion THDi% | ≥ 5% @ rated voltage | ||||||||
| OUTPUT DATA | |||||||||
| Voltage | 200/208/220/230/240Vac single phase | ||||||||
| Voltage tolerance (battery mode) | ±1% | ||||||||
| Frequency (syncronisation range) | 47Hz : 53Hz or 57Hz : 63 Hz | ||||||||
| Frequency (battery mode range) | 50Hz ± 0.1Hz or 60Hz ± 0.1Hz | ||||||||
| Crest Factor | 3 : 1 | ||||||||
| Harmonic distortion | ≤ 2% THD (linear load) ≤ 4% THD (non linear load) | ||||||||
| Transfer time | Line to battery | Zero | |||||||
| In verter to by-pass | 4 ms (typical) | ||||||||
| Wave form (battery mode) | PURE SINE WAVE | ||||||||
| EFFICIENCY | |||||||||
| With line voltage | 89% | 91% | |||||||
| Battery | ≈ 88 ÷ 90% | ||||||||
| BATTERIES | |||||||||
| Standard model | Battery type | 12V / 9 Ah | 12V / 9 Ah | 12V / 9 Ah | 12V / 9 Ah | ||||
| No. Of batteries | 2 | 3 | 4 | 6 | |||||
| Typical charging time | 4 h for 90% capacity | ||||||||
| Charging current (max) | 2 A @ 12 A settable | 2 A @ 8 A settable | |||||||
| Charging voltage | 27.4Vdc ±1% | 41.1Vdc ±1% | 54.8Vdc ±1% | 82.1Vdc ±1% | |||||
| SIGNALS | |||||||||
| LCD Panel |
UPS state – Load level – battery level – input/output voltage – battery discharge time – fault |
||||||||
| ALARMS | |||||||||
| Battery operated | Beep every 5” | ||||||||
| Low battery | Beep every 2” | ||||||||
| Overload | Beep every 1” | ||||||||
| Fault | Continuous beep | ||||||||
| Dimensions and weight | |||||||||
| Standard model | Dimensions DxWxH mm | 410x438x88 | 410x438x88 | 510x438x88 | 630x438x88 | ||||
| Net weight kg. | 12 | 15 | 20 | 28 | |||||
| Model without battery | Dimensions DxWxH mm | 410x438x88 | 410x438x88 | 510x438x88 | 510x438x88 | ||||
| Net weight kg. | 7 | 8 | 10 | 13 | |||||
| ENVIRONMENTAL CONDITIONS | |||||||||
| Humidity | 20 ÷ 90% RH @ 0 ÷ 40°C (without condensation) | ||||||||
| Noise | < 50Dba @ 1 m. | ||||||||
| INTERFACES | |||||||||
| Smart RS232/USB | Windows family, linux, Unix, Mac | ||||||||
| Optional SNMP | Power management for SNMP manager and web browser | ||||||||
| MODEL | ERT106K | ERT110K | |||
| POWER | 6KVA/6KW | 10KVA/10KW | |||
| INPUT DATA | |||||
| Voltage | Rated voltage | 200/208/220/230/240Vac single phase | |||
| Voltage range | 110-300Vac ±5% a 50% load
176-300Vac ±5% a 100% load |
||||
| Low voltage threshold | 170Vac ±5% | ||||
| High voltage threshold | 290Vac ±5% | ||||
| Frequency range | 46:54Hz @ 50Hz / 56:64Hz @ 60Hz | ||||
| Number of phases | Single phase with earth | ||||
| PF Power factor | ≥ 0.99 at rated voltage (load 100%) | ||||
| Harmonic Distortion THDi% | < 4% @ 100% del carico, < 6% @ 50% load | ||||
| OUTPUT DATA | |||||
| Voltage | 200/208/220/230/240Vac single phase | ||||
| Voltage tolerance (battery mode) | ±1% | ||||
| Frequency (syncronisation range) | 46Hz : 54Hz or 56Hz : 64 Hz | ||||
| Frequency (battery mode range) | 50Hz ± 0.1Hz or 60Hz ± 0.1Hz | ||||
| Crest Factor | 3 : 1 | ||||
| Harmonic distortion | ≤ 2% THD (linear load) ≤ 4% THD (non linear load) | ||||
| Transfer time | Line to battery | Zero | |||
| Inverter to by-pass | Zero | ||||
| Wave form (battery mode) | PURE SINE WAVE | ||||
| EFFICIENCY | |||||
| With line voltage | 94% | ||||
| Battery | 92% | ||||
| BATTERIES | |||||
| Standard model | Battery type | 12V / 7.2 Ah | 12V / 9 Ah | ||
| No. Of batteries | 20 | 20 | |||
| Typical charging time | 7 h at 90% capacity | 9 h at 90% capacity | |||
| Charging current (max) | 1.0 A @ 4.0 A | ||||
| Charging voltage | 273.0Vdc | ||||
| SIGNALS | |||||
| LCD Panel |
UPS state – Load level – battery level – input/output voltage – battery discharge time – fault |
||||
| ALARMS | |||||
| Battery operated | Beep every 5” | ||||
| Low battery | Beep every 2” | ||||
| Overload | Beep every 1” | ||||
| Fault | Continuous beep | ||||
| Dimensions and weight | |||||
| Standard model | Dimensions DxWxH mm | UPS 610X438X88 (2U)+ batt. 600x438x133 (3U) | UPS 610X438X88 (2U)+ batt. 600x438x133 (3U) | ||
| Net weight kg. | 17+57 | 20+63 | |||
| Model without battery | Dimensions DxWxH mm | 610x438x88 (2U) | 668x438x88 (2U) | ||
| Net weight kg. | 17 | 20 | |||
| ENVIRONMENTAL CONDITIONS | |||||
| Humidity | 0 ÷ 95% RH @ 0 ÷ 40°C (without condensation) | ||||
| Noise | < 58Dba @ 1 m. | < 60Dba @ 1 m. | |||
| INTERFACES | |||||
| Smart RS232/USB | Windows family, linux, Unix, Mac | ||||
| Optional SNMP | Power management for SNMP manager and web browser | ||||